The successful use of the plasma-sprayed HA-coated Ti-6AI-4V system requires strong adhesion between the ceramic coating and the underlying metal substrate. The aim of this study was to evaluate the bond strength at the HA coating (HAC)/Ti-6AI-4V interface, for specimens that had and had not been subjected to immersion in a pH-buffered, serum-added simulated body fluid (SBF). Moreover, coating characteristics affecting the mechanical stability after having been immersed in SBF were clarified. The results showed that bonding degradation of approximately 25–33% of the original strength was measured after immersion in SBF, and that this predominantly depended on the characteristics of the HAC and the period of immersion. Since the surface morphologies of HACs have dissolved in the SBF, it is suggested that the interlamellar structure of the HAC was weakened and, therefore, the bond strength degraded. As both the crystallinity and impurity phases of the HAC increased with immersion time, it can be concluded that the dissolution of the HAC resulting from the initial microstructure has overtaken that of the coating crystallinity and phase purity. A denser microstructure is required to ensure a satisfactory HAC/Ti-6AI-4V interface.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
M. S.Block, J. N.Kent and J. F.Kay, J. Oral Maxillofac. Surg. 45 (1987) 601.
R. G. T.Geesink, K.deGroot and C. P. A. T.Klein, J. Bone Joint Surg. 70B (1988) 17.
S. D.Cook, K. A.Thomas, J. F.Kay and M.Jarcho, Clin. Orthop. 232 (1988) 225.
D. P.Rivero, J.Fox, A. K.Skipor, R. M.Urban and J. O.Galante, J. Biomed. Mater. Res. 22 (1988) 191.
K.Soballe, E. S.Hansen, H. B.Rasmussen, C. M.Pedersen and C.Bunger, Acta Orthop. Scand. 61 (1990) 299.
D.Buser, R. K.Schenk, S.Steinemann, J. P.Fiorellini, C. H.Fox and H.Stich, J. Biomed. Mater. Res. 25 (1991) 889.
J. A.Jansen, J. P. C. M.van deWaerden, J. G. C.Wolke and K.deGroot, J. Biomed. Mater. Res. 25 (1991) 973.
M.Gottlander and T.Albrektsson, Int. J. Oral Maxillofac. Imp. 6 (1991) 339.
B. C.Wang, E.Chang, D.Tu and C. Y.Yang, J. Mater. Sci. Mater. Med. 4 (1993) 394.
B. C.Wang, E.Chang and C. Y.Yang, J. Biomed. Mater. Res. 27 (1993) 1315.
R. G. T.Geesink, Clin. Orthop. 261 (1990) 39.
T. W.Bauer, R. G. T.Geesink, R.Zimmerman and J. T.McMahon, J. Bone Joint Surg. 73A (1991) 1439.
M. J.Filiaggi, N. A.Coombs and R. M.Pilliar, J. Biomed. Mater. Res. 25 (1991) 1211.
H.Ji, C. B.Ponton and P. M.Marquis, J. Mater. Sci. Mater. Med. 3 (1992) 283.
M. L.Filiaggi, N. A.Coombs and R. M.Pilliar, Mater. Res. Soc. Symp. Proc. 153 (1989) 377.
R. M.Pilliar, D. A.Deporter, P. A.Watson, M.Pharoah, M.Chipman, N.Valiquette, S.Carter and K.deGroot, J. Dent. Res. 70 (1991) 1338.
J. M.Spivak, J. L.Ricci, N. C.Blumenthal and H.Alexander, J. Biomed. Mater. Res. 24 (1990) 1121.
S. D.Cook, J. F.Kay, K. A.Thomas and M.Jarcho, Int. J. Oral Maxillofac. Imp. 2 (1987) 15.
B. C.Wang, E.Chang, C. Y.Yang, D.Tu and C. H.Tasi, Surf. Coat. Technol. 58 (1993) 107.
E.Munting, M.Verhelpen, F.Li and A.Vincent, in “CRC handbook of bioactive ceramics,” edited by T.Yamamuro, L. L.Hench and J.Wilson (CRC Press, Florida, 1990) pp. 143–148.
H.Ji and P. M.Marquis, Biomaterials 14 (1993) 64.
W. J. A.Dhert, C. P. A. T.Klein, J. G. C.Wolke, E. A.van derVelde and K.deGroot, J. Biomed. Mater. Res. 25 (1991) 1183.
C. P. A. T.Klein, P.Patka, H. B. M.van derLubbe, J. G. C.Wolke and K.deGroot, J. Biomed. Mater. Res. 25 (1991) 53.
C. Y.Yang, B. C.Wang, E.Chang and J. D.Wu, J. Mater. Sci. Mater. Med. 6 (1995) 249.
K.deGroot, C. P. A. T.Klein, J. G. C.Wolke and J. M. A.deBlieck-Hogervorst, in “CRC handbook of bioactive ceramics,” edited by T.Yamamuro, L. L.Hench and J.Wilson (CRC Press, Florida, 1990) pp. 133–142.
K.deGroot, C. P. A. T.Klein, J. G. C.Wolke and J. M. A.deBlieck-Hogervorst, in “CRC handbook of bioactive ceramics,” edited by T.Yamamuro, L. L.Hench and J.Wilson (CRC Press, Florida, 1990) pp. 3–16.
P.Ducheyne, J.Cuckler, S.Radin and E.Nazar, in “CRC handbook of bioactive ceramics,” edited by T.Yamamuro, L. L.Hench and J.Wilson (CRC Press, Florida, 1990) pp. 123–131.
K. A.Gross and C. C.Berndt, Proceedings of 2nd Plasma-Technik Symposium Plasma-Technik AG, Wohlen 3 (1991) 159.
K.Shimazaki and V.Mooney, J. Orthop. Res. 3 (1985) 301.
P. S.Eggli, W.Muller and R. K.Schenk, Clin. Orthop. 232 (1988) 127.
L.Xie and E. A.Monroe, in “CRC handbook of bioactive ceramics,” edited by T.Yamamuro, L. L.Hench and J.Wilson (CRC Press, Florida, (1990) pp. 29–37.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yang, C.Y., Wang, B.C., Chang, E. et al. Bond degradation at the plasma-sprayed HA coating/Ti-6AI-4V alloy interface: an in vitro study. J Mater Sci: Mater Med 6, 258–265 (1995). https://doi.org/10.1007/BF00120268
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00120268