Abstract
In recent years, with the increase in sitting time, real-time posture monitoring system is needed. We developed sitting posture monitoring system with accelerometer to evaluate postural balance. Unstable structure of the system was designed to assess asymmetrical balance caused by habitual sitting position. Postural patterns of normal group and patients with functional scoliosis group were analyzed. Consequently, inclination angle of scoliosis group were tilted to the posterior and left side. From these results, we concluded that real-time sitting posture monitoring system can be utilized to measure asymmetrical balance of patients and provide accurate diagnosis as well as treatment for individuals.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
References
Gopalai, A.A., Senanayake, S.M., Kiong, L.C., Gouwanda, D.: Real-time Stability Measurement System for Postural Control. J. Bodyw. Mov. Ther. 15, 453-464 (2011)
Bechly, K.E., Carender, W.J., Myles, J.D., Sienko, K.H.: Determining the preferred modality for real-time biofeedback during balance training. Gait Posture. 37, 391–396 (2013)
Mukhopadhyay, S.C., Ihara, I.: Sensors and Technologies for Structural Health Monitoring: A Review. In: Mukhopadhyay. S.C. (eds.) New Development in Sensing Technology for Structural Health Monitoring 2011. LNEE, vol. 96, pp. 1-14. Springer, Heidelberg (2011)
Gupta, P., Dallas, T.: Feature Selection and Activity Recognition System using a Single Triaxial Accelerometer. IEEE Trans. Biomed. Eng. 61, 1780-1786 (2014)
Karantonis, D.M., Narayanan, M.R.: Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. IEEE Trans. Int. Tech. Biomed. 10, 156-167 (2006)
Curone, D., Bertolotti, G.M., Cristiani, A., Secco, E.L., Magenes, G.: A real-time and self-calibrating algorithm based on triaxial accelerometer signals for the detection of human posture and activity. IEEE Trans. Inf. Tech. Biomed. 14, 1098-1105 (2010)
Bliley, K.E., Schwab, D.J., Holmes, D.R., Kane, P.H., Levine, J.A., Daniel, E.S., Gilbert, B.K.: Design of a compact system using a MEMS accelerometer to measure body posture and ambulation. In: 19th IEEE International Symposium on Computer-Based Medical Systems, pp. 335-340. IEEE Press, Utah (2006)
Wang, Z.W., Wang, W.J., Sun, M.H., Liu, Z., Zhu, Z.Z., Zhu, F., Qiu, X.S., Qian, B.P., Wang, S.F., Qiu, Y.: Characteristics of the pelvic axial rotation in adolescent idiopathic scoliosis: a comparison between major thoracic curve and major thoracolumbar/lumbar curve. Spine J. 14, 1873-1878 (2014)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Jung, JY., Bok, SK., Kim, BO., Won, Y., Kim, JJ. (2015). Real-time Sitting Posture Monitoring System for Functional Scoliosis Patients. In: Kim, K. (eds) Information Science and Applications. Lecture Notes in Electrical Engineering, vol 339. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-46578-3_46
Download citation
DOI: https://doi.org/10.1007/978-3-662-46578-3_46
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-46577-6
Online ISBN: 978-3-662-46578-3
eBook Packages: EngineeringEngineering (R0)