Skip to main content

Pedicle Screw Implantation Using the DISOS Template System

  • Chapter
Navigation and Robotics in Total Joint and Spine Surgery

Abstract

In computer-aided pedicle-screw implantation, exactly as in conventional procedures, correct positioning of the screw is only possible based on a precise knowledge of the anatomical structure in question. The choice of screw length and caliber depends to a great extent on detailed knowledge about this structure [6]. Generally, the greater the screw length and caliber, the better the anchoring [4]. In addition, particular attention must be paid to ventral boundaries and the constant danger of perforation in the area of the spinal cord. The proximity of the spinal column means the greatest care is required in introducing the screw in order to avoid damage to surrounding neural and vascular structures. Placement of a pedicle screw is therefore difficult since there is no direct view into the spine. In particular, problems can arise with medial or caudal placement of the screw, possibly resulting in serious neurological dysfunction. In the literature, faulty placements (perforations) using conventional procedures are reported to range from between 8.5% [2], 15.9% [9], 39.9% [3], and 42% [5].

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Birnbaum K, Schkommodau E, Decker N, Prescher A, Klapper U, Radermacher K (2001) Computer-assisted orthopedic surgery with individual templates an comparison to conventional operation method.Spine 26: 365–370.

    Article  PubMed  CAS  Google Scholar 

  2. Haaker RG, Eickhoff U, Schopphoff E et al. (1997) Verification of the position of pedicle screws in lumbar spinal fusion. Eur Spine J 6:125–128.

    Article  PubMed  CAS  Google Scholar 

  3. Jerosch J, Malms J, Castro WHM et al. (1992) Lagekontrolle von Pedikelschrauben nach instrumentierter dorsaler Fusion der Lendenwirbelsäule. Z Orthop 130:479–483.

    Article  PubMed  CAS  Google Scholar 

  4. Krag MH (1988) Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. J Spinal Disorders 1:287–294.

    Article  CAS  Google Scholar 

  5. Merloz P, Tonetti J, Pittet L et al. (1998) Pedicle screw placement using image guided techniques. Clin Orthop 354:39–48.

    Article  PubMed  Google Scholar 

  6. Olsewski JM, Simmons EH, Kallen FC et al. (1990) Morphometry of the lumbar spine: anatomical perspectives related to transpedicular fixation. J Bone Joint Surg 72:541–549.

    PubMed  CAS  Google Scholar 

  7. Radermacher K, Portheine F, Anton M et al. (1998) Computer assisted orthopaedic surgery with image-based individual templates. Clin Orthop 354:28–38.

    Article  PubMed  Google Scholar 

  8. Radermacher K (1999) Computerunterstützte Operationsplanung und -ausführung mittels individueller Bearbeitungsschablonen in der Orthopädie. Berichte aus der Biomedizinischen Technik, Bd 7. Shaker, Aachen.

    Google Scholar 

  9. Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9[Suppl 1]:S57–64.

    Article  PubMed  Google Scholar 

  10. D Arning A, Bloch M, Heinecke A, Kalchschmidt K (1994) Triple pelvic osteotomy. J Pediatr Orthop 3:54–67.

    Article  Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2004 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Schkommodau, E., Decker, N., Klapper, U., Birnbaum, K., Staudte, HW., Radermacher, K. (2004). Pedicle Screw Implantation Using the DISOS Template System. In: Navigation and Robotics in Total Joint and Spine Surgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59290-4_70

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-59290-4_70

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-63922-7

  • Online ISBN: 978-3-642-59290-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics