Abstract
Promising mitral valve (MV) repair concepts include leaflet augmentation and saddle shaped annuloplasty, and recent long-term studies have indicated that excessive tissue stress and the resulting strain-induced tissue failure are important etiologic factors leading to the recurrence of significant MR after repair. In the present work, we are aiming at developing a high-fidelity computational framework, incorporating detailed collagen fiber architecture, accurate constitutive models for soft valve tissues, and micro-anatomically accurate valvular geometry, for simulations of functional mitral valves which allows us to investigate the organ-level mechanical responses due to physiological loadings. This computational tools also provides a means, with some extension in the future, to help the understanding of the connection between the repair-induced altered stresses/strains and valve functions, and ultimately to aid in the optimal design of MV repair procedure with better performance and durability.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
- Mitral Valve
- Mitral Regurgitation
- Important Etiologic Factor
- Mitral Valve Apparatus
- Small Angle Light Scattering
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Carpentier, A.: Cardiac valve surgery–the French correctoin. J. Thorac. Cardiovasc. Surg. 86(3), 323–337 (1983)
Goldsmith, I.R., Lip, G.Y., Patel, R.L.: A prospective study of changes in the quality of life of patients following mitral valve repair and replacement. Eur. J. Cardiothorac. Surg. 20(5), 949–955 (2001)
Driessen, N.J.B., Boerboom, R.A., Huyghe, J.M., Bouten, C.V., Baaijens, F.P.: Computational analyses of mechanically induced collagen fiber remodeling in the aortic heart valve. J. Biomech. Eng. 125(4), 549–557 (2003)
Boerboom, R., Driessen, N.J.B., Bouten, C.C., Huyghe, J., Baaijens, F.T.: Finite element model of mechanically induced collagen fiber synthesis and degradation in the aortic valve. Ann. Biomed. Eng. 31(9), 1040–1053 (2003)
Kunzelman, K.S., Cochran, R.P., Chuong, C., Ring, W.S., Verrier, E.D., Eberhart, R.D.: Finite element analysis of the mitral valve. J. Heart Valve Dis. 2(3), 326–340 (1993)
Kunzelman, K.S., Reimink, M.S., Cochran, R.P.: Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: a finite element model. J. Heart Valve Dis. 7(1), 108–116 (1998)
Einstein, D.R., Kunzelman, K.S., Reinhall, P.G., Nicosia, M.A., Cochran, R.P.: The relationship of normal and abnormal microstructural proliferation to the mitral valve closure sound. J. Biomech. Eng. 127(1), 134–147 (2005)
Sacks, M.S., Smith, D.B., Hiester, E.D.: The aortic valve microstructure: Effects of transvalvular pressure. J. Biomed. Mater. Res. 41(1), 131–141 (1998)
Cochran, R.P., Kunzelman, K.S., Chuong, C.J., Sacks, M.S., Eberhard, R.C.: Nondestructive analysis of mitral valve collagen fiber orientation. ASAIO Trans. 37(3), M447–M448 (1991)
Sacks, M.S.: Incorporation of experimentally-derive fiber orientation into a structural constitutive model for planar collagenous tissues. J. Biomech. Eng. 125(2), 280–287 (2003)
Gorman, J.H., Gupta, K.B., Streicher, J.T., Gorman, R.C., Jackson, B.M., Ratcliffe, M.B., Bogen, D.K., Edmunds Jr., L.H.: Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. J. Thorac. Cardiovasc. Surg. 112(3), 712–726 (1996)
Grashow, J.S., Yoganathan, A.P., Sacks, M.S.: Biaxial stress-stretch behavior of the mitral valve anterior leaflet at physiologic strain rates. Ann. Biomed. Eng. 34(2), 315–325 (2006)
He, Z., Ritchie, J., Grashow, J.S., Sacks, M.S., Yoganathan, A.P.: In vitro dynamic strain behavior of the mitral valve posterior leaflet. J. Biomech. Eng. 127(3), 504–511 (2005)
Kunzelmann, K.S., Cochran, R.P.: Mechanical properties of basal and marginal mitral valve chordae tendineae. ASAIO Trans. 36, M405–M408 (1990)
Kunzelman, K.S., Einstein, D.R., Cochran, R.P.: Fluid-structure interaction models of the mitral valve: function in normal and pathological states. Phil. Trans. Soc. B 362, 1393–1406 (2007)
Sun, W., Abad, A., Sacks, M.S.: Simulated bioprosthetic heart valve deformation under quasi-static loading. J Biomech. Eng. 127, 1–9 (2005)
Prot, V., Haaverstad, R., Skallerud, B.: Finte element analysis of the mitral apparatus: annulus shape effect and chordae force distribution. Biomech. Model Mechanobiol. 8, 43–55 (2009)
Lau, K.D., Diaz, V., Scambler, P., Burriesci, G.: Mitral valve dynamics in structure and fluid-structure interaction models. Med. Eng. Phys. 32, 1057–1064 (2010)
Wang, Q., Sun, W.: Finite element modeling of mitral valve dynamic deformation using patient-specific multi-slices computed tomography scans. Annals Biomed. Eng. (2012), doi:10.1007/s10439-012-0620-6
Aggarwal, A., Aguilar, V.S., Lee, C.H., Gorman, J.H., Gorman, R.C., Sacks, M.S.: Spline based microstructural mapping for soft biological tissues: application to aortic valves. In: 11th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (2013)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Lee, CH. et al. (2013). A High-Fidelity and Micro-anatomically Accurate 3D Finite Element Model for Simulations of Functional Mitral Valve. In: Ourselin, S., Rueckert, D., Smith, N. (eds) Functional Imaging and Modeling of the Heart. FIMH 2013. Lecture Notes in Computer Science, vol 7945. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-38899-6_49
Download citation
DOI: https://doi.org/10.1007/978-3-642-38899-6_49
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-38898-9
Online ISBN: 978-3-642-38899-6
eBook Packages: Computer ScienceComputer Science (R0)