Abstract
This paper introduces an analysis about the Steady State Visual Evoked Potential (SSVEP) present in electroencefalogram (EEG) signals. This analysis was performed under some features. Firstly, the flickering stimuli varied along the 5.5–86.0 Hz range, and two types of settings were used, a monopolar and a bipolar. The analysis outputs were SSVEP amplitude response and its signal-to-noise ratio (SNR). These features were discriminated according to the three frequency ranges: low, medium and high frequency. Moreover, a subjective discomfort evaluation was performed through a questionnaire, which was answered by the 20 participating volunteers. Finally, it is shown that this study is in accordance with the literature statements about the SSVEP’s power and SNR behavior regarding the oscillating stimuli frequencies.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
When an individual stares at a flickering light, which flickers at a constant frequency, or visualizes a sudden light change, electrical potentials are generated on his scalp via visual pathways neurons [1, 2]. These so-called Visually Evoked Potentials (VEPs) can be understood as a reorganization of spontaneous brain oscillations due to exterior stimuli [3] and some authors call this a resonance phenomena [4, 5]. VEPs can be subdivided into two types: Transient VEPs and Steady-State VEPs, which will be used in this study. For more information on how these potentials are understood and classified, please check [6].
In 1966, Regan [7] published a pioneer study on stimulating the human retina with long sinusoidal modulated monochromatic light. By averaging the achieved signal response he was able to obtain the then-called average steady state response. The study demonstrated that after a 12–20 s period of repetitive light stimulation, the average response was remaining rather constant in amplitude and phase. This behavior was then later attributed to Steady State Visually Evoked Potentials (SSVEPs). However, what really gives SSVEPs its name is under the frequency domain. Vialatte et al. [3] highlights that an organized response with stationary periodic oscillations is the main difference between steady state and transient VEPs.
The way that SSVEP response varies its amplitude along the stimulation frequency axis has been demonstrated by many authors. Regan [8] divided the SSVEP response frequency spectrum into three regions: low-, medium- and high-frequency ones, presenting peaks at 10 Hz, 16 Hz 50 Hz, respectively. Wang et al. [9] also divided it into three regions named just like Regan’s, but with peaks at 15 Hz, 31 Hz 41 Hz. Other studies used stimulus frequency beyond the conscious perception threshold, also called critical flickering frequency (CFF), such as [5, 10] and [11]. These works showed evidences for SSVEP response appearance at stimuli frequencies higher than 50 Hz. Note that CFF is understood as the limit at which humans start to perceive flickering light as continuous.
Among possible applications, SSVEPs are used in Brain-computer interfaces (BCIs) development. A SSVEP-based BCI uses EEG signals as input to command output devices. Nevertheless, there are some issues related to the SSVEP-based BCI development, which are the number, location and selection of EEG channels to be used, and noise reduction of EEG recordings. Former studies such as [12, 13] affirm that a bipolar electrode setting has the most suitable response for SSVEP-based BCIs. Moreover, [9] also suggests that a bipolar electrode setting diminishes the noise present at SSVEPs responses.
Thus, the current study analyzes the SSVEP response produced by a blinking green-light emitter LED [14] stimuli in the range from 5.5 to 86.0 Hz. This way, the experiment includes the low-, medium- and high-frequency stimuli ranges and also proposes a new nomenclature to high-frequency stimuli beyond the critical flickering frequency, such as [15] but with a higher resolution inside this range. Another subject studied in this work is the phenomena related to SSVEP’s Signal-to-Noise Ratio (SNR). Here, the spontaneous EEG signal is taken as noise because it is not an event-related VEP. According to [9], this noise decreases with increasing stimuli frequency, as well as the signal itself, allowing to maintain the SNR approximately constant throughout the studied frequency range.
Considering the importance of analyzing the subjective influence that tiredness and other subjective feelings has upon SSVEP amplitude as presented in [16], a subjective analysis was performed from volunteers’ responses to an applied questionnaire. Finally, besides analyzing SSVEP amplitude and SNR behaviours, they are analyzed under monopolar and bipolar settings. With this, the paper aims to study and describe the behavior of the human SSVEP response in a large range of frequencies and to have data on how people feel when using a SSVEP-based BCI system.
2 Methods
This section describes the experimental procedures, the EEG signal acquisition equipment and the volunteers characteristics.
2.1 Volunteers and EEG Signal Acquisition
Twenty volunteers (nine female) took part on the experiment. The average age and its standard deviation are 24.75 and 7.37 years. Seven volunteers wear glasses and 2 are left handed.
The EEG signals were recorded with a Grass 15LT bioamplifier system, composed of 15A54 Quad-amplifier (Astro-med, Inc.) with opto-coupled inputs, and digitized with a NI-DAQPad6015. The sample frequency 512 Hz and 12 EEG channels in occipital region were placed as shown in Fig. 1a. The volunteers sat on a comfortable chair at 60–70 cm away from a computer monitor with a box (2.5 cm \(\times \) 2.5 cm) on top of the screen, illuminated by high-efficiency green-light-emitting diodes (LEDs) controlled with precision by a FPGA Xilinx Spartan2E.
2.2 Experimental Procedure
The experiment was composed by three sessions, which were classified regarding the LED flickering frequency (low-, medium- and high-frequency), as shown in Table 1. The high-frequency range, at the data analysis, was subdivided into two ranges since there are different frequency steps for each range. Moreover, this subdivision is justified due to some volunteers report that they perceived the flickering stimulus as continuous for frequencies higher than 45 Hz, as it is of interest dividing the high-frequency range below and above the CFF.
Each session has a number of trials according to its frequency range as shown in Table 1. The timeline for each trial is illustrated in Fig. 1b. Before each trial there is a resting (or inter-trial) interval, without stimulation. Then, an audible warning allowed the volunteers to be attentive to the coming stimulus. Two seconds later, the stimulus begins and at the end of the trial a sound indicated whether the frequency was correctly identified.
2.3 Applied Questionnaire
The volunteers were asked to fill out a questionnaire. This was done with the purpose of having information on how people subjectively feel while undergoing the experiment. Initially and after each session, the volunteers had to give graduated answers to the following questions:
- Q1:
-
How much discomfort did the cap cause to you? (0—None, 10—Great discomfort);
- Q2:
-
What is your current state of mind? (1—Very sad, 10—Very happy);
- Q3:
-
What is your current calmness level? (1—Very calm, 10—Very altered);
- Q4:
-
What is your current self-esteem level? (1—Little confident, 10—Very confident);
- Q5:
-
What is your current tiredness level? (0—Well rested, 10—Very tired);
- Q6:
-
How much discomfort did the stimuli from the last session cause to you? (0—None, 10—Great discomfort);
- Q7:
-
What was your concentration level during the last session? (0—None, 10—Very concentrated).
2.4 Signal Processing
After data collecting, the raw EEG signals were processed in some steps. First, the signal DC component has been removed; after, it was spatially filtered using a Common Average Reference (CAR) filter, which used the signal from all of 12 EEG channels. Then, an elliptic Infinite Impulse Response (IIR) band-pass filter was used, with a pass-band of 3–90 Hz plus a notch filter 50 Hz due to the country line frequency.
In this work, two variables were used to study the SSVEP behavior: the response amplitude and the signal-to-noise ratio (SNR). The SSVEP amplitude response over the frequency was determined by the data normalization at the amplitude spectrum, as shown in Eq. (1).
where x is the processed EEG signal containing the SSVEP information, FFT(x) is the fast Fourier transform of x and \( \sum |FFT(\textit{x})| \) represents the summation of the amplitudes over all the frequency spectrum, thereby normalizing the sum of the amplitude spectrum to one. Moreover, the signal-to-noise ratio (SNR) was defined by Wang et al. [9] as the ratio of FFT(f) to the mean value of the n adjacent points to the stimulus frequency f, as shown in Eq. (2).
where f is the stimulus frequency, F is the Fourier power of the signal, and \( \Delta f \) is the Fourier transform precision or frequency step. The number of adjacent points to the frequency of stimulation f was of 20 in this data processing. Since the frequency resolution is of 0.1 Hz, 10 neighbor points to the stimulus frequency analyzed can give results when compared to numbers up to 1 Hz difference, to each side of it. Previous studies such as [17,18,19] have used a frequency resolution of 0.2 Hz and 8 adjacent points, reaching a range of \(\pm {0.8}\) Hz with the stimulus frequency as reference.
After using Eqs. (1) and (2) for all stimulus frequency of all volunteers, an average value of amplitude response and SNR were determined for each stimulation frequency.
3 Results and Discussion
The results can be analyzed regarding two aspects: qualitative and quantitative evaluations. The qualitative assessment concerns the values presented in the questionnaire by the volunteers. This allows to assess the discomfort influence in the experiment execution, which is presented and discussed in Sect. 3.1. The quantitative analysis concerns the SSVEP amplitude response as well as its SNR value. These results are presented in a graphical mode in Sect. 3.2.
3.1 Questionnaire Results
The self-assessment questionnaire results are presented at Tables 2 and 3. Each column number represents the answer for one of the questions presented at Sect. 2.3, according the graduation given by the volunteer.
Table 2 presents the volunteers answers before the experiment starting. The average values were Q1:1.2, Q2: 7.2, Q3: 1.85, Q4: 5.5, Q5:2.35. It means that the cap caused little discomfort at the experiment starting for all the volunteers. Moreover, an average current state of mind of 7.2, plus an average calmness level of 1.85, indicate volunteers’ willingness to participate in the experiment. An average current self-esteem level of 5.5 can represent the volunteers’ expectation of what will happen during the experiment. Finally, an average current tiredness level of 2.35 may be related to a good night sleeping the day before. Thus, a scenario of good conditions for the volunteers was set up.
The experiment was conducted using the three ranges presented in Table 1, which were randomly presented to the volunteers. Here, the high-frequency range comprises the High and Ultra-high ranges. Each volunteer had its own randomly generated sessions’ order, as presented at Table 3. Moreover, Table 3 shows how the discomfort increased for most part of the volunteers throughout the experiment. The average values are Q1: 2.0,3.45,4.65; Q5: 2.85,4.05,4.45; Q6: 2.5,3.95,3.6; Q7: 7.45,6.85,7.6.
As expected, the average cap discomfort increased over time, as shown in Q1 answers. Starting with a 1.2 grade (see Table 2), it increased to 2.0 after the first session, then it changed to 3.45 after the second session and kept rising until the last session, which had a grade of 4.65. The same reasoning can be applied to the Q5 answers, which means that the tiredness level also increases over time. Initiating at the grade of 2.35 (see Table 2) and going up to 2.85, 4.05 and 4.45 along the sessions.
However, the graduations for Q6 and Q7 answers do not present an increasing or decreasing characteristic. This was already expected since these questions refer to the stimulus discomfort and concentration level at certain frequency range. Both questions are dependent on the stimuli frequency region, which were presented randomly to the volunteers.
Considering then an average for each frequency range, the low-, medium- and high-frequency ranges present a discomfort (Q6) equal to 3.8, 2.9 and 3.35, respectively. This shows how the volunteers had minimal discomfort at the medium-frequency region frequencies. However, it is important to highlight here that the high-frequency region was composed by frequencies above and below the critical flickering frequency, and this should be studied later. For Q7 question, if the average is taken for each frequency range instead of averaging the values along the experiment, the calculated values were 7.3, 7.55 and 7.0 for low-, medium- and high-frequency ranges, respectively. This probably shows that the subjects felt as they were not able to focus on the stimulus at the high-frequency levels as much as on the low- and medium-frequency ones.
However, a new analysis is necessary and this analysis must consider the separation of the ultra-high-frequency range values from the high-frequency range ones.
3.2 SSVEP Amplitude Response and SNR
As presented in Sect. 1, studies already known in the literature have shown peaks at SSVEPs’ amplitude spectra in three frequency regions. Namely, Regan [8] with peaks at 10, 16 50 Hz, and Wang et al. [9] with peaks at 15, 31 41 Hz. The current work seeks to confirm these statements in addition to complementing them with an increase in the frequency range analyzed. Moreover, the results are presented for monopolar and bipolar settings, with the monopolar setting or EEG channel chosen was Oz and the bipolar setting chosen was the POz-Oz. These choices were made from the conclusions obtained in [12].
Thus, Fig. 2 shows the averaged SSVEPs normalized amplitude spectra, which the response for monopolar setting (Oz) is presented at Fig. 2a and for the POz-Oz bipolar setting is pictured at Fig. 2b. It can be observed that the bipolar setting has a higher amplitude response until the end of High-1 region (45 Hz, see Table 1) comparing to the monopolar setting. Then, this bipolar setting was chosen for discussing the averaged amplitude spectrum analysis.
Figure 2b shows peaks 10 Hz 16 Hz, as pointed out by Regan [8]. Unfortunately the electric line had 50 Hz frequency and it did not allow to check the SSVEP amplitude at this stimulation frequency, showed at that study as the high-frequency peak. Using Wang’s study [9] for comparison, it also can be seen a peak at 31 Hz. However, the 41 Hz peak showed by him was not the peak here, and it was assumed that 38 Hz stimulation frequency would be the established peak for the high-frequency region.
At the ultra-high-frequency region (45 Hz), the monopolar setting shows a higher amplitude response, so the Fig. 2a will be used for the SSVEP amplitude response analysis. This region could be subdivided into two regions: one with a local peak 62 Hz and another with a peak 84 Hz. The 62 Hz peak remains visible also at the bipolar setting amplitude spectrum (Fig. 2b), while the 84 Hz peak does not. Herrmann’s study [5] states the existence of a peak around 80 Hz stimulation frequency, which is close to the 84 Hz peak appearance here, but it leads us to a new peak at the now-called ultra-high-frequency region. All these evidences show that the current work is in accordance with the literature on the appearance of three (and now four) different frequency regions.
Regarding the SNR analysis, Wang’s study [9] shows peaks at 16 Hz, 32 Hz 43 Hz. However, in the current work, considering bipolar setting, the SSVEP SNR presents peaks at about 6.5 Hz, 10 Hz, 15.5 Hz, 20 Hz, 21.5 Hz, 31 Hz, 35.5 Hz, 40 Hz 42 Hz, as seen at Fig. 3b. The SNR remains rather constant until the end of the high-frequency region, which can explain the appearance of so many local peaks, in contrast with the amplitude spectrum.
Moreover, just like the averaged amplitude response, the SNR shows the same behavior for stimuli frequencies at the ultra-high-frequency region having a higher value at the monopolar setting and then diminishing significantly when compared to the other regions. Checking the Fig. 3a it can be seen peaks at 56 Hz, 74 Hz and a peak at 84 Hz. Values close to the one pointed by Herrmann’s study [5].
4 Conclusion
Two analysis were performed at this current work, a quantitative and a qualitative one. The quantitative analysis presented new evidences on the SSVEP response amplitude and SNR, supporting the current literature about the division of its spectra into three regions (low, medium and high). It was also proposed the definition of a new region, called here as ultra-high-frequency region. The qualitative analysis presented a complementary study related to the volunteers feelings on each frequency region throughout the experiment.
If a correlation is performed between the quantitative and qualitative analysis some conclusion can be taken. Despite having the highest levels of response amplitude and SNR, the low-frequency region presents the most discomfortable stimuli for the participants, and it shows that this frequency range might not be a good option for SSVEP-based applications. The study also shows that although having the minimal SNR and response amplitude among all the regions, the high-frequency SNR levels still have values that show that this region might be a good option for a SSVEP-based tools. This region analysis presented 80 Hz stimulus frequency local peak, showing slight accordance with Herrmann’s work [5].
The study showed a 3.55 grade of discomfort for high-frequency region, but a separation between the high- and ultra-high-frequency regions was not made, and it must be done in further work to check if the stimuli above the critical flickering frequency could be a good option for an application. The attempt for using the ultra-high-frequency region is important, since humans perceive the flickering light as continuous which might lead to a region of minimal discomfort.
Even more, the current work provided information about the peaks at each frequency region for SSVEP response amplitude and SNR. It was in accordance with two of Regan’s [8] peaks (10 and 16 Hz), and one of Wang’s [9] (31 Hz). However, peaks at different, but close, stimuli frequencies also appeared, such as the one 38 Hz (in contrast with Wang’s [9] 41 Hz and Herrmann’s [5] 40 Hz peaks for the high-frequency region).
Subsequent studies can be performed but now dividing the high-frequency stimuli region during the experiment into two different regions, enabling to accomplish a more detailed analysis of the human SSVEP response behavior to 5.5–86.0 Hz flicker stimulation.
References
Başar E, Gönder A, Ungan P (1976) Important relation between EEG and brain evoked potentials. Biolog Cybernet 25:27–40
Regan D, Spekreijse H (1986) Evoked potentials in vision research 1961–1986. Vis Res 26:1461–1480
Vialatte F-B, Maurice M, Dauwels J, Cichocki A (2010) Steady-state visually evoked potentials focus on essential paradigms and future perspectives. Progr Neurobiol 90:418–438
Petar H, Christa N, Gernot M-P, Horki P (2011) Identifying “resonance” frequencies for SSVEP-BCI. Int J Bioelectromagnet 13:76–77
Herrmann CS (2001) Human EEG responses to 1–100 Hz flicker, resonance phenomena in visual cortex and their potential correlation to cognitive phenomena. Exp Brain Res 137:346–353
Regan D (1982) Comparison of transient and steady-state methods. Ann NY Acad Sci 388(1):45–71
Regan D (1966) Some characteristics of average steady-state and transient responses evoked by modulated light. Electroencephalogr Clin Neurophys 20:238–248
Regan D (2009) Some early uses of evoked brain responses in investigations of human visual function. Vis Res 49:882–897
Wang Y, Wang R, Gao X, Hong B, Gao S (2006) A practical VEP based brain computer interface. IEEE Trans Neural Syst Rehabil Eng 14:234–239
Ramos-Júnior Sérgio G, Celino DR, Rodor FF et al (2011) Experimental evidences for visual evoked potentials with stimuli beyond the conscious perception threshold. In: Proceedings of ISSNIP biosignals and biorobotics conference, 5pp
Sakurada T, Kawase T, Komatsu T, Kansaku K (2015) Use of high-frequency visual stimuli above the critical flicker frequency in a SSVEP-based. BMI Clin Neurophys 126:1972–1978
Müller SMT, Bastos-filho TF, Sarcinelli-filho M (2015) Monopolar and bipolar electrode settings for SSVEP-based brain-computer. Interface J. Med. Biolog. Eng. 35:482–491
Diez PF, Vicente M, Eric L, Enrique A (2010) A comparison of monopolar and bipolar EEG recordings for SSVEP detection. In: 2010 annual international conference of the IEEE engineering in medicine and biology society, EMBC’10, pp 5803–5806
Tello RJMG, Müller SMT, Ferreira A, Bastos TF (2015) Comparison of the influence of stimuli color on steady-state visual evoked potentials. Rev Bras Eng Biomed 31:218–231
Bakardjian H, Tanaka T, Cichocki A (2010) Optimization of SSVEP brain responses with application to eight-command brain-computer interface. Neurosci Lett 469:34–38
Müller SMT, Diez PF, Bastos-Filho TF et al (2014) Commanding a robotic wheelchair using high- or low-frequency SSVEP-BCI: a comparative study. In: Proceedings of the 6th international brain-computer interface conference, vol 1, pp 1–4
Chen X, Chen Z, Gao S, Gao X (2014) A high-ITR SSVEP-based BCI speller. Brain-Comput Interfaces 1:181–191
Floriano A, Diez PF, Bastos-Filho TF (2018) Evaluating the influence of chromatic and luminance stimuli on SSVEPs from behind-the-ears and occipital areas. Sensors (Switzerland) 18
Floriano A, Carmona VL, Diez PF, Bastos-Filho TF (2019) A study of SSVEP from below-the-hairline areas in low-, medium-, and high-frequency ranges. Res Biomed Eng 35:71–76
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Statement of Human Rights
The experiments were performed according to the rules of the Consejo de Bioetica from the Facultad de Ciencias Exactas Fisicas y Naturales, at the Universidad Nacional de San Juan (Ata N7).
Rights and permissions
Copyright information
© 2022 Springer Nature Switzerland AG
About this paper
Cite this paper
Ferreira, G.S., Diez, P.F., Müller, S.M.T. (2022). Analysis About SSVEP Response to 5.5–86.0 Hz Flicker Stimulation. In: Bastos-Filho, T.F., de Oliveira Caldeira, E.M., Frizera-Neto, A. (eds) XXVII Brazilian Congress on Biomedical Engineering. CBEB 2020. IFMBE Proceedings, vol 83. Springer, Cham. https://doi.org/10.1007/978-3-030-70601-2_232
Download citation
DOI: https://doi.org/10.1007/978-3-030-70601-2_232
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-70600-5
Online ISBN: 978-3-030-70601-2
eBook Packages: EngineeringEngineering (R0)