Abstract
In the past three years we have developed a diffraction tomography system for research in medical imaging.1,2 The system was designed to address some of the aspects of current medical ultrasound that limit its use in many applications. For example, high-resolution ultrasound is restricted to a small field of view which can make it difficult to locate the area of interest and which does not allow ready comparison of normal and suspected abnormal tissues. As a result, the quality of medical sonography greatly depends on the skill of the operator who must recognize the important images and capture them on film for review by physicians. The findings of sonography are therefore not easily reproduced.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
M.P. André, P.J Martin, G.P. Otto, L.K. Olson, T.K. Barrett, B.A. Spivey, D. A. Palmer, “A new consideration of diffraction computed tomography for breast imaging: Studies in phantoms and patients,” Acoustical Imaging 21, (1995), in press.
P.J. Martin, M.P. André, B.A. Spivey, D.A. Palmer, “Sonic computed tomography for breast imaging.” In: Breast Ultrasound, B.J. Hackeloer, H. Madjar, J. Taubner, Eds. (S. Karger, Freiburg, 1994), pp 52–58.
D. Kopans, J. Meyer, K. Lindfors, “Whole breast US imaging; four-year follow-up,” Radiology 157, 505–507 (1985).
E. Sickles, R. Filly, P. Callen, “Breast cancer detection with sonography and mammography,” Amer J Roentgenol 140, 843–845 (1983).
M. Kaveh, R. Mueller, R. Rylander, T. Coulter, M. Soumekh, “Experimental results in ultrasonic diffraction tomography,” Acoustical Imaging 9, 433–450 (1979).
A. Devaney, “A filtered backpropagation algorithm for diffraction tomography,” Ultrasonic Imaging 4, 336–350 (1982).
J.F. Greenleaf, S.A. Johnson, W.F. Samayoa, F.A. Duck, Algebraic reconstruction of spatial distributions of acoustic velocities in tissue from their time-of-flight profiles, in: “Acoustic Holography,” N. Booth, ed., Plenum, New York, (1975).
P.L. Carson, C.R. Meyer, A.L. Scherzinger, T.V. Oughton, “Breast imaging in coronal planes with simultaneous pulse-echo and transmission ultrasound,” Science 214:1141–1143 (1981).
M.P. André, H.S. Janée, G.P. Otto, P.J. Martin, “Diffraction tomography with large-scale toroidal arrays,”Intl J Imaging Systems & Technol 8, (1996), in press.
E.L. Madsen, J.A. Zagzebski, G.R. Frank, “Oil-in-gelatin dispersions for use as ultrasonically tissuemimicking materials,” Ultrasound in Med & Biol 8(3):277–287 (1982).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1996 Springer Science+Business Media New York
About this chapter
Cite this chapter
André, M.P., Janée, H.S., Otto, G.P., Martin, P.J., Jones, J.P. (1996). Reduction of Phase Aberration in a Diffraction Tomography System for Breast Imaging. In: Tortoli, P., Masotti, L. (eds) Acoustical Imaging. Acoustical Imaging, vol 22. Springer, Boston, MA. https://doi.org/10.1007/978-1-4419-8772-3_24
Download citation
DOI: https://doi.org/10.1007/978-1-4419-8772-3_24
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-4687-6
Online ISBN: 978-1-4419-8772-3
eBook Packages: Springer Book Archive