Abstract
A new method is introduce for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The method is based on the application of motion compensated techniques to the acquired angiograms resulting in a temporal snapshot of the stent within the cardiac cycle. For the first time results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current x-ray and intravascular ultrasound techniques.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Nieman, K., Cademartiri, F., Raaijmakers, R., Pattynama, P., de Feyter, P.: Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography. Herz 28(2), 136–142 (2003)
Nieman, K., Ligthart, J.M.R., Serruys, P.W., de Feyter, P.J.: Left main rapamycin-coated stent: Invasive versus noninvasive angiographic follow-up. Circulation 105, 130–131 (2002)
Funabashi, N., Komiyama, N., Komuro, I.: Patency of coronary artery lumen surrounded by metallic stent evaluated by three dimensional volume rendering images using ecg gated multislice computed tomography. Heart 89, 388 (2003)
Maintz, D., Juergens, K., Wichter, T., Grude, M., Heindel, W., Fischbach, R.: Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur. Radiol. 13(4), 830–835 (2003)
Maintz, D., Seifarth, H., Flohr, T., Kramer, S., Wichter, T., Heindel, W., Fischbach, R.: Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol. 38(12), 790–795 (2003)
Degertekin, M., Ligthart, J.M., Oortman, R.M., Serruys, P.W., Slager, C.J., Tanabe, K., Gijsen, F.J.: Images in cardiovascular medicine. true three-dimensional reconstructed images showing lumen enlargement after sirolimus-eluting stent implantation. Circulation 106(22), e179–180 (2002)
Delachartre, P., Brusseau, E., Guerault, F., Finet, G., Cachard, C., Vray, D.: Correction of geometric artifacts in intravascular ultrasound imaging during stent implantation. In: IEEE International Ultrasonics Symposium, Caesars Tahoe, Nevada (1999)
Movassaghi, B., Rasche, V., Viergever, M.A., Niessen, W.J.: 3D coronary reconstruction from calibrated motion-compensated 2D projections based on semi-automated feature point detection. In: Proc. SPIE Medical Imaging: Image Processing, San Diego, CA, vol. 5370, pp. 1943–1950 (2004)
Blondel, C., Vaillant, R., Malandain, G., Ayache, N.: 3-d tomographic reconstruction of coronary arteries using a precomputed 4-d motion field. Physics in Medicine and Biology 49(11), 2197–2208 (2004)
Shechter, G., Devernay, F., Coste-Maniere, E., Quyyumi, A., McVeigh, E.R.: Three-dimensional motion tracking of coronary arteries in biplane cineangiograms. IEEE Trans. Med. Imag., 493–503 (2003)
Moriyama, M., Sato, Y., Naito, H., Hanayama, M., Ueguchi, T., Harada, T., Yoshimoto, F., Tamura, S.: Reconstruction of time-varying 3-d left-ventricular shape from multiview X-ray cineangiocardiograms. IEEE Trans. Med. Imag. 21(7), 773–785 (2002)
Blondel, C., Vaillant, R., Devernay, F., Malandain, G., Ayache, N.: Automatic trinocular 3d reconstruction of coronary artery centerlines from rotational x-ray angiography. In: Computer Assisted Radiology and Surgery 2002 Proceedings (CAR 2002), pp. 832–837. Springer, Heidelberg (2002)
Movassaghi, B., Rasche, V., Florent, R., Viergever, M.A., Niessen, W.J.: 3D coronary reconstruction from calibrated motion-compensated 2D projections. In: Computer Assisted Radiology and Surgery (CARS 2003), pp. 1079–1084. Elsevier, Amsterdam (2003)
Netsch, T., Peitgen, H.O.: Scale-space signatures for the detection of clustered microcalcifications in digital mammograms. IEEE Trans. Med. Imag. 18(9), 774–786 (1999)
Netsch, T.: A scale-space approach for the detection of clustered microcalcifications in digital mammograms. In: Digital Mammography 1996, pp. 301–306 (1996)
Keating, T.J., Wolf, P.R., Scarpace, F.L.: An improved method of digital image correlation. Photogrammetric Eng. Remote Sensing 41, 993–1002 (1975)
Grass, M., Koppe, R., Klotz, E., Proksa, R., Kuhn, M.H., Aerts, H., Op de Beek, J., Kemkers, R.: 3D reconstruction of high contrast objects using C-arm image intensifer projection data. Computer. Med. Imaging Graphics 23(6), 311–321 (1999)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Movassaghi, B. et al. (2006). 3D Reconstruction of Coronary Stents in Vivo Based on Motion Compensated X-Ray Angiograms. In: Larsen, R., Nielsen, M., Sporring, J. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2006. MICCAI 2006. Lecture Notes in Computer Science, vol 4191. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11866763_22
Download citation
DOI: https://doi.org/10.1007/11866763_22
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-44727-6
Online ISBN: 978-3-540-44728-3
eBook Packages: Computer ScienceComputer Science (R0)