4. Conclusions
A fiber-optic biosensing system for the simultaneous quantification of four cardiac markers is currently under development, in our research group, for rapid coronary disease diagnosis and prognosis. As an initial effort, four individual BNP, cTnI, MG, and CRP sensors were developed. The sensors showed excellent performance in quantifying these cardiac markers in their clinically significant ranges within 15 minutes, at a S/N ratio of 25–50. The cross-reactivity of the four sensors was also found to be negligible. A mixture of four AF647-2o Mabs has shown only a slight interference to the four sensors, indicating that the mixture can be applied through a multi-sensing unit for simultaneous detection with an easier operation.
Other future work includes simultaneous quantification of these four cardiac markers using a multi-sensing unit. A microfluidic system will be incorporated in the unit for precise fluid control. Micro-electro-mechanical systems (MEMS) technology will be utilized for the development of an automatic, smaller, and more cost-effective biosensing chip.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
- Human Serum Albumin
- Cardiac Marker
- Simultaneous Quantification
- Biosensing System
- Human Serum Albumin Solution
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
6. References
American Heart Association, Heart disease and stroke statistics-2004 update, pp. 9–11 (2004).
A. S. Maisel, P. Krishnaswamy, R. M. Nowak, et al. Rapid measurement of B-type natriuretic peptide in the emergency diagnosis of heart failure, New Engl. J. Med. 347, 161–167 (2002).
M. S. Sabatine, D. A. Morrow, J. A. de Lemos, C. M. Gibson, S. A. Murphy, N. Rifai, C. McCabe, E. M. Antman, C. P. Cannon, E. Braunwald, Multimarker approach to risk stratification in non-ST elevation acute coronary syndromes: Simultaneous assessment of troponin I, c-reactive protein, and b-type natriuretic peptide, Circulation 105, 1760–1763 (2002).
ESC/ACC. Consensus document, myocardial infarction redefined: A consensus document of the joint European society of cardiology/American college of cardiology committee for the redefinition of myocardial infarction, Eur. Heart J. 21, 1502–1513 (2002).
J. McCord, R. M. Nowak, P. A. McCullough, et al. Ninety-minute exclusion of acute myocardial infarction by use of quantitative point-of-care testing of myoglobin and troponin I, Circulation 104, 1483–1488 (2001).
F. S. Ligler, J. P. Golden, L. C. Shriver-Lake, R. A. Ogert, D. Wijesuria, G. P. Anderson, Fiber-optic biosensor for the detection of hazardous materials, Immunomethods 3, 122–127 (1993).
J. O. Spiker and K. A. Kang, Preliminary study of real-time fiber optic based protein C biosensor, Biotech. Bioeng. 66(3), 158–163 (1999).
H. I. Balcer, H. J. Kwon, and K. A. Kang, Assay procedure optimization of rapid, reusable protein immunosensor for physiological samples, Ann. Biomed. Eng. 30(10), 141–147 (2002).
H. J. Kwon, H. I. Balcer, and K. A. Kang, Sensing performance of protein C immuno-biosensor for biological samples and sensor minimization, Comparative Biochem. Phys. A 132, 231–238 (2002).
L. Tang and K. A. Kang, Preliminary study of simultaneous multi-anticoagulant deficiency diagnosis by fiber optic multi-analyte biosensor, proceedings of 2003 Annual ISOTT Meeting, Aug. 16–20, 2003, Rochester, NY, in press.
S. K. Bhatia, L. C. Shriver-Lake, K. J. Prior, J. H. Georger, J. M. Calvert, R. Bredehorst, F. S. Ligler, Use of thio-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces, Anal. Biochem. 178, 408–413 (1989).
L. Tang, H. J. Kwon, and K. A. Kang, Studies on effect of sample circulation on sensing performance of protein C immunosensor, proceedings of the 24th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 3, 1805–1806 (2002).
L. Tang and K. A. Kang, Sensing performance improvement of protein C biosensor by sample circulation, Adv. Exp. Med. Biol. 540, 177–182 (2003).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer Science+Business Media, Inc.
About this paper
Cite this paper
Tang, L., Kang, K.A. (2006). Preliminary Study of Fiber Optic Multi-Cardiac-Marker Biosensing System for Rapid Coronary Heart Disease Diagnosis and Prognosis. In: Cicco, G., Bruley, D.F., Ferrari, M., Harrison, D.K. (eds) Oxygen Transport to Tissue XXVII. Advances in Experimental Medicine and Biology, vol 578. Springer, Boston, MA . https://doi.org/10.1007/0-387-29540-2_16
Download citation
DOI: https://doi.org/10.1007/0-387-29540-2_16
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-387-29543-5
Online ISBN: 978-0-387-29540-4
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)