Abstract
The CAS neonatal NIRS system determines absolute regional brain tissue oxygen saturation (SnO2) and brain true venous oxygen saturation (SnvO2) non-invasively. Since NIRS-interrogated tissue contains both arterial and venous blood from arterioles, venules, and capillaries, SnO2 is a mixed oxygen saturation parameter, having values between arterial oxygen saturation (SaO2) and cerebral venous oxygen saturation (SVO2). To determine a reference for SnO2, the relative contribution of SvO2 to SaO2 drawn from a brain venous site vs. systemic SaO2 is approximately 70:30 (SvO2:SaO2). If the relationship of the relative average contribution of SvO2 and SaO2 is known and does not change to a large degree, then NIRS true venous oxygen saturation, SnvO2, can be determined non-invasively using SnO2 along with SaO2 from a pulse oximeter.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
P. B. Benni, Method for non-invasive spectrophotometric blood oxygenation monitoring, U.S. Patent No. 6,456,862, USPTO, (2002).
R. Pettignano, M. Labuz, T. Gauthier, J. Huckaby, and R. Clark, The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation, Crit. Care 1(3), 95–99 (1997).
N. C. Brun, A. Moen, K. Borch, O. D. Saugstad, and G. Greisen, Near-infrared monitoring of cerebral tissue oxygen saturation and blood volume in newborn piglets, Am. J. Physiol. 273(2 Pt. 2), H682–H686 (1997).
H. M. Watzman, C. D. Kurth, L. M. Montenegro, J. Rome, J. M. Steven, and S. C. Nicolson, Arterial and venous contributions to near-infrared cerebral oximetry, Anesthesiol. 93(4), 947–953 (2000).
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Science+Business Media, Inc.
About this paper
Cite this paper
Benni, P.B. et al. (2005). Validation of the Cas Neonatal NIRS System by Monitoring VV-ECMO Patients. In: Okunieff, P., Williams, J., Chen, Y. (eds) Oxygen Transport to Tissue XXVI. Advances in Experimental Medicine and Biology, vol 566. Springer, Boston, MA. https://doi.org/10.1007/0-387-26206-7_27
Download citation
DOI: https://doi.org/10.1007/0-387-26206-7_27
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-387-25062-5
Online ISBN: 978-0-387-26206-2
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)