The aim of this investigation is to study the applicability of the Passivhaus standard to typical housing projects in the Colombian market. Dynamic simulations run in IESVE for a detached house and an apartment block revealed that under the business-as-usual construction scenario slightly cold indoor conditions are perceived in the cold climate of Bogotá (−0.8 ≤ PMV ≤ 0.15), while pronounced overheating (1.45 ≤ PMV ≤ 1.95) is predicted in the hot climate of Barranquilla. The implementation of typical passive design measures significantly improves indoor conditions in the cold climate of Bogotá, making these housing designs fulfil the Passivhaus energy requirements. On the other hand, in the hot climate of Barranquilla, these measures are not sufficient to meet the standard prescriptions, and thus further passive strategies should be sought along with the use of highly efficient cooling systems.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Passive House Institute: http://passivehouse.com/02_informations/01_whatisapassivehouse/01_whatisapassivehouse.htm. Accessed 5 March 2019

  2. Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings

    Google Scholar 

  3. Consoli, A., Costanzo, V., Evola, G., Marletta, L.: Refurbishing an existing apartment block in Mediterranean climate: towards the Passivhaus standard. Energy Procedia 111, 397–406 (2017)

    Article  Google Scholar 

  4. Costanzo, V., Fabbri, K., Piraccini, S.: Stressing the passive behavior of a Passivhaus: an evidence-based scenario analysis for a Mediterranean case study. Build. Environ. 142, 265–277 (2018)

    Article  Google Scholar 

  5. Piderit, M.B., Vivanco, F., Van Moeseke, G., Attia, S.: Net Zero Buildings—a framework for an integrated policy in Chile. Sustainability 11, 1494 (2019)

    Article  Google Scholar 

  6. Ford, B., Schiano-Phan, R., Zhong, D.: The Passivhaus standard in European warm climates: design guidelines for comfortable low energy homes. School of the built environment, University of Nottingham (2007)

    Google Scholar 

  7. Badescu, V., Rotar, N., Udrea, I.: Considerations concerning the feasibility of the German Passivhaus concept in Southern Hemisphere. Energy Effic. 8, 919–949 (2015)

    Article  Google Scholar 

  8. Schnieders, J., Feist, W., Rongen, L.: Passive Houses for different climate zones. Energy Build. 105, 71–87 (2015)

    Article  Google Scholar 

  9. Attia, S., Zawaydeh, S.: Strategic decision making for zero energy buildings in Jordan. In: Proceedings of the ASHRAE International Conference on Energy and Indoor Environment for Hot Climates, February 24–26, Doha (2014)

    Google Scholar 

  10. Kottek, M., Grieser, J., Beck, C., Rudolf, B., Rubel, F.: World map of the Köppen-Geiger climate classification updated. Meteorol. Z. 15(3), 259–263 (2006)

    Article  Google Scholar 

  11. IES, Integrated Environmental Solutions: https://www.iesve.com/. Accessed 5 March 2019

  12. Wilcox, S., Marion, W.: User’s manual for TMY3 Data Sets. Technical Report NREL/TP-581-43156 (2008)

    Google Scholar 

  13. Meteonorm: https://meteonorm.com/en/. Accessed 5 march 2019

  14. Fanger, P.O.: Thermal Comfort. Danish technical Press, Copenhagen (1970)

    Google Scholar 

  15. Natarajan, S., Rodriguez, J., Vellei, M.: A field study of indoor thermal comfort in the subtropical highland climate of Bogota, Colombia. J. Build. Eng. 4, 237–246 (2015)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vincenzo Costanzo .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Costanzo, V., Carrillo Gómez, J.E., Evola, G., Marletta, L. (2020). Suitability of Passivhaus Design for Housing Projects in Colombia. In: Littlewood, J., Howlett, R., Capozzoli, A., Jain, L. (eds) Sustainability in Energy and Buildings. Smart Innovation, Systems and Technologies, vol 163. Springer, Singapore. https://doi.org/10.1007/978-981-32-9868-2_9

Download citation

Publish with us

Policies and ethics