This paper presents the results of the experimental investigations on the influence of concrete strength, and confinement effect of different arrangements of hoops on the bond-slip relationship between reinforcing steel bars and concrete. The Pull-out tests according to the recommendations of RILEM CEB RC6 were conducted to determine the bond strength-slips relationship. A set of 27 specimens were prepared for the testing with two main parameters, including concrete strength and stirrup spacing. Based on the current test results, the effects of such variable of interest on the behavior of RC structural elements are discussed.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
Reinforced concrete structures are widely used in housing construction, bridges, roads, irrigation. Bond slip relationship between reinforcing bar and surrounding concrete is the basic factor that ensures the general working of concrete and reinforcement in reinforced concrete structures. Among the factors affecting the adhesion force between the concrete and the reinforcement, the influence of the strength of the concrete and the reinforcement is very important. The research purpose of the topic is to clarify the effect of compressive strength of concrete and columnar stirrup on adhesion between concrete and longitudinal reinforcement.
This paper presents an Experimental study on the bond strength between reinforcement bars and concrete as a function of concrete strength and confinement effect. The experimental research is carried out at Laboratory of Testing and Construction Inspection, National University of Civil Engineering, Vietnam.
2 Experimental Research
2.1 Test Specimens and Materials
The pull-out tests were conducted on the recommendations of RILEM-CEB RC 6 (Fig. 1). The bond length between rebar and concrete of 60 mm (5Φ) were located in the mid of specimens and two PVC tubes with 45 mm length were used to isolate the non-bonding length. The free-end were elongated to measure the slip deformation. The planning of the tests is shown in Table 1, including two groups. The 18 cube specimens with dimensions of 150 × 150 × 150 mm3 were fabricated and test for determining the influence of concrete compressive strength, called Group 1. The 9 rectangular prism specimens with dimensions of 150 × 100 × 300 mm3 and the different arrangements of stirrup space were performed for determining the influence of stirrups on the bond strength between the steel bars and concrete, called Group 2.
The ribbed steel bars with 12 mm diameters and AII grade were used in the total specimens. The stirrups with 6 mm diameters spaced at 40 mm and 80 mm were arranged perpendicular to the steel bars, as shown in Fig. 2.
A range of 17.52 to 75.58 MPa strength concrete was used to produce the specimens of the test (refer to Table 1).
The mix ratios of concrete are shown in Table 2. The types of cement are Portland cement with strength grade of PCB30 for concrete with compressive strengths from 17.2 MPa to 33.4 MPa and strength grade of PCB40 for concretes with compressive strengths from 59.82 MPa to 75.58 MPa.
Three 150 × 150 × 150 mm3 concrete cube per each sample were tested in order to obtain its compressive strength. The average concrete strengths after 28 days are shown in Table 1.
2.2 Test Setup and Instrumentation
During the test, the applied forces were recorded through a computerized data-logger system. The test procedure is described as follows:
-
a.
Arranging instrumentation for the test specimen (Fig. 3)
-
b.
Carrying out loading increment (100kg/step)
-
c.
At each increment, reading and recording the value of the indicator.
-
d.
Repeat the b and c step until failure phenomena occurs
At every loading step, all test data including the applied load and vertical deformations are recorded with Data Logger TDS-530.
3 Test Results and Discussions
3.1 Influence of the Concrete Strength
Figure 3 shows the comparison of bond strength—slip curves of specimens Group 1 that has six values of concrete strength, ranging from 17,5 MPa to 75,58 MPa. Each curve in Fig. 3 is set of average values from results of three same test specimens. From the graph, it is clear that the bond strength between steel bar and concrete increases with increasing concrete strength. The change of compressive strength from 17.5 MPa to 33.14 MPa, the behavior of the bond-slip divided into four states, while the others is unclear.
The process of developing adhesion force is divided into 04 stages as follows:
Stage 1: Choosing adhesion at this time is mainly the adhesive force of cement mortar. This phase does not appear cracks in the concrete. Shift δ increases slowly.
Stage 2: Starting to appear cracks between the concrete and the reinforcement, the pressure of the reinforcement on the concrete increases, the displacement δ increases gradually.
Stage 3: Cracks develop, adhesion force reaches maximum value. Teleport δ increases rapidly. Adhesion force is mainly due to the edge of the reinforcement acting on the concrete.
Stage 4: The force value remains constant for a short time and then decreases rapidly, the displacement δ continues to increase rapidly until the concrete-reinforced linkage is damaged (Fig. 4).
When the concrete strength increases from 17.5 MPa and 75.58Mpa, the τmax value increases 2 times while the τmin value increases 4.4 times. Relative displacement of concrete and reinforcement (δ max) decreases gradually as the concrete strength increases. The detail shows in Fig. 5.
3.2 The Effect of Stirrup Spacing
The value of the adhesion force at the onset of the relative displacement between the reinforcement and the concrete τmin of the sample with the smaller belt spacing (a = 40) is larger than that of the sample with a large belt spacing (a = 80) (Fig. 6).
Experimental results show that the sample with a smaller distance (a = 40mm) has the largest value of adhesion force (τmax) than the sample with a large belt distance (a = 80mm).
For the test sample with a belt arrangement, when the concrete is expanded, the belt acts to prevent the lateral expansion of the concrete, the more expands the concrete, the tighter the belt will squeeze the concrete. Concrete holds the reinforcement tighter or increases the adhesion force between the reinforcement and the concrete in the concrete-reinforced structure.
4 Conclusions
Stirrups and the compressive strength of concrete have significant effects on bond force between concrete and reinforcing bars in reinforced concrete structures. Bond force is directly proportional with the compressive strength of concrete. An increase in the compressive strength of concrete may slows down the process of breaking the bond between concrete and reinforcements.
Failure mechanism of the bond has its root from the failure of concrete zones contacting with steel interfaces. Stirrups in reinforced concrete members play a role in confining horizontal expansion, which increases the bond force between concrete and reinforcements. In addition, the bond stress increases when increasing the percentage of stirrup.
References
ACI 318—99, Building code requirements for Structural Concrete,
AS 3600—2009, Australian Standard for concrete structures, Standard Australia, Sydney
Eurocode 2, Design of Concrete Structures.
RILEM TC, “RILEM Recommendations for the Testing and Use of Construction Materials,
RC 6 Bond Test for Reinforcement Steel. Pull-Out Test, 1983”. E&FN SPON, 1994.
TCVN 5754–2018: Design of Concrete and Reinforced Concrete Structures, Vienamese Standard (2018)
SNIP 2.03.01–84, “Guidelines for Design of Concrete and reinforced concrete structures made of heavy—weight and light—weight concrete without reinforcement prestress
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Xuan, V.T., Manh, H.N., Trung, H.N., Xuan, D.P. (2022). Experimental Study on the Bond Strength Between Reinforcement Bars and Concrete as a Function of Concrete Strength and Confinement Effect. In: Ha-Minh, C., Tang, A.M., Bui, T.Q., Vu, X.H., Huynh, D.V.K. (eds) CIGOS 2021, Emerging Technologies and Applications for Green Infrastructure. Lecture Notes in Civil Engineering, vol 203. Springer, Singapore. https://doi.org/10.1007/978-981-16-7160-9_25
Download citation
DOI: https://doi.org/10.1007/978-981-16-7160-9_25
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-7159-3
Online ISBN: 978-981-16-7160-9
eBook Packages: EngineeringEngineering (R0)