Abstract
In this paper we present a new series of unirradiated and pre-irradiated uranium doped glass discs that were manufactured and characterized for use in fission-track analysis. They are issued as Nuclear Reference Material IRMM-540. The certified quantities are the uranium mass fraction [=13.9 mgxkg−1], the n(235U)/n(238U) amount ratio [=0.007277] and the thermal Maxwellian neutron fluence [=1.070x1019 m−2]. Additional information is given related to the nominal composition of the glass and its content of thorium and neutron absorbing elements, the uranium homogeneity between and within discs, the neutron fluence monitors, the parameters of the neutron spectrum in the irradiation facility, the thermal stability of the fission tracks in the glass and the properties of the mica that has been used as external detector in contact with the irradiated discs.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Aarnio P.A., Routti J.T. and Sandberg J.V. (1988): Microsampo-Personal computer based advanced gamma spectrum analysis system. J. Radioanal. Chem. 124, 457–466.
Bellemans F., De Corte F. and Van den haute P. (1995): Composition of SRM and CN U-doped glasses: significance for their use as thermal neutron fluence monitors in fission track dating. Radiation Measurements 24/2, 153–160.
Bellemans F. (1996): Een nucleair-analytische bijdrage tot de absolute kalibratie van de fissiesporendateringsmethode. Ph D Thesis, University of Gent, 177 pp.
Bigazzi G. (1993): oral communication.
Carpenter S.B. (1984): Standard reference materials: calibrated glass standards for fission track use. Natn. Bur. Stand. Spec. Publ. 260–292.
Crowley K.D. (1986): Neutron dosimetry in fission-track analysis. Nucl. Tracks Radiat. Meas. 11, 237–243.
De Corte F., Simonits A., De Wispelaere A. and Hoste J. (1987): Accuracy and applicability of the (-standardization method. J. Radioanal. Nucl. Chem. 113, 145–161.
De Corte F., Van den haute P., De Wispelaere A. and Jonckheere R. (1991): Calibration of the fission-track dating method: is Cu useful as an absolute thermal neutron fluence monitor? Chem. Geol. (Isot. Geosci. Sect.), 86, 187–194.
De Corte F., Bellemans F., De Neve P. and Simonits A. (1994): The use of a modified Westcott-formalism in the ko-standardization of NAA: the state of affairs. J. Radioanal. Nucl. Chem., Articles 179, 93–103.
De Corte F., Van den haute P. and Bellemans F. (1995). The use of uranium doped glasses in fission-track dating. Radiation Measurements 25/1–4, 511–516.
De Wispelaere A., Bellemans F. and De Corte F. (1992): Tuning the geometric parameters of a Ge detector for accurate efficiency calculation via program SOLANG: demonstration with detector AMANDA. Proceed. Intern. k o Users Workshop–Gent, 1992 ( F. De Corte, editor ), INW/RUG, 45–48.
Hurford A.J. and Green P.F. (1982). A user’s guide to fission track dating calibration. Earth Planet. Sci. Lett. 59, 343–354.
ENDF/B-VI (1991): ENDF/B Summary Documentation, fourth edition (ENDF/B-VI). BNL-NCS-17541, ENDF-201, National Neutron Cross-Section Center, Brookhaven National Laboratory, USA.
Holden N.E. (1991): Temperature dependence of the Westcott g-factor for neutron capture reactions. In: ENDF/B-VI. BNL-46465 Report, 36`h IUPAC general assembly, Hamburg, Germany.
Ingelbrecht C., Peetermans F., De Corte F., De Wispelaere A., Vandecasteele C., Courtijn E. and D’Hondt P. (1991): Aluminium-gold reference material for the ko-standardization of neutron activation analysis. Nucl. Instr. Meth. Phys. Res. A303, 119–122.
Moens L., De Donder J., Lin Xilei, De Corte F., De Wispelaere A., Simonits A. and Hoste J. (1981): Calculation of e for different counting geometries. Nucl. Instr. Meth. 187, 451–472.
Reimer G.M., Wagner G.A. and Carpenter B.S. (1972): The thermal stability of fission tracks in the standard reference material glass standard (National Bureau of Standards). Radiation Effects, 15, 273–274.
Tagami T. and Nishimura S. (1989): Intercalibration of thermal neutron dosimeter glasses NBS-SRM612 and Corning 1 in some irradiation facilities: a comparison. Nucl. Tracks Radiat. Meas. 16, 11–14.
Tagami T. and Nishimura S. (1992): Neutron dosimetry and fission-track age calibration insights from intercalibration of uranium and thorium glass dosimeters. Chem. Geol. (Isot. Geosci. Sect.) 102, 277–296.
Van den haute P., Jonckheere R. and De Corte F. (1988): Thermal neutron fluence determination for fission track dating with metal activation monitors: a re-investigation. Chem. Geol. (Isot. Geosci. Sect.) 73, 233–244.
Wagner G.A. and Van den haute P. (1992): Fission-Track Dating. Enke Verlag - Kluwer Academic Publishers, 285 pp.
Westcott C.H. (1962): Effective cross section values for well-moderated thermal reactor spectra. In: Report CRRP-960 of the Atomic Energy of Canada Limited [Nov. 1, 1960 (reprinted 1962)].
Westphal G.P. (1982): Real-time correction of counting losses in nuclear pulse spectroscopy. J. Radioanal. Chem. 70, 387–410.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
de Corte, F., Bellemans, F., van den Haute, P., Ingelbrecht, C., Nicholl, C. (1998). A New U Doped Glass Certified By the European Commission for the Calibration of Fission-Track Dating. In: van den Haute, P., de Corte, F. (eds) Advances in Fission-Track Geochronology. Solid Earth Sciences Library, vol 10. Springer, Dordrecht. https://doi.org/10.1007/978-94-015-9133-1_5
Download citation
DOI: https://doi.org/10.1007/978-94-015-9133-1_5
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-4977-3
Online ISBN: 978-94-015-9133-1
eBook Packages: Springer Book Archive