Abstract
Artefacts can be defined as false features in the image that significantly alter the interpretation of the patient anatomy and pathology. For the radiologist, the recognition of artefacts is important to avoid incorrect diagnoses, and therefore precise knowledge of them is mandatory. Artefacts as well as other 3D (three-dimensional) representation methods affect virtual endoscopy. The appearance of artefacts in endoluminal views may add further difficulties to the interpretation of virtual endoscopy images (Bode et al. 2001). Artefacts can be grouped into two types, in relation to the phases of virtual endoscopy generation: image acquisition and image processing.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Batra P, Bigoni B, Manning J (2000) Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography. Radiographics 20:309–320.
Bode A, Dammann F, Pelikan EH (2001) Analysis of artifacts by virtual endoscopy visualization of spiral CT data. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:245–252.
Guazzaroni M, Turchio P, Di Rienzo L (2001) Virtual laryngoscopy of neoplastic pharyngeal and laryngeal pathology. Radiol Med 101:265–269.
Laghi A, Catalano C, Panebianco V (2000) Optimization of the technique of virtual colonoscopy using a multislice spiral computerized tomography. Radiol Med 100:459–464.
Lauenstein T, Holtmann G, Shoenfelder D (2001) MR colonography without colonic cleansing: a new strategy to improve patient acceptance. AJR 177:823–827.
Morrin MM, Farrell RJ, Kruskal JB (2000) Utility of intravenously administered contrast material at CT colonography. Radiology 217:765–771.
Rodenwaldt J, Kopka L, Roedel R (1997) 3D virtual endoscopy of the upper airway: optimization of the scan parameters in a cadaver phantom and clinical assessment. J Comput Assist Tomogr 21:405–411.
Schoenfelder D, Debatin JF (2000) Virtual reality in MR colonography. Radiologe 40:283–289.
Whiting BR, McFarland EG, Brink JA (2000) Influence of image acquisition parameters on CT artifacts and polyp depiction in spiral CT colonography: in vitro evaluation. Radiology 217:165–172.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Neri, E., Vagli, P., Picchietti, S. (2002). Pitfalls and Artefacts in Virtual Endoscopy. In: Caramella, D., Bartolozzi, C. (eds) 3D Image Processing. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59438-0_7
Download citation
DOI: https://doi.org/10.1007/978-3-642-59438-0_7
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-63977-7
Online ISBN: 978-3-642-59438-0
eBook Packages: Springer Book Archive