Abstract
The primary physiological task of the cardiovascular system is to deliver enough oxygen (O2) to meet the metabolic demands of the body. Shock and tissue hypoxia occur when the cardiorespiratory system is unable to cover metabolic demand adequately. Sustained tissue hypoxia is one of the most important cofactors in the pathophysiology of organ dysfunction [1]. Therefore determining the adequacy of tissue oxygenation in critically ill patients is central to ascertain the health of the patient. Unfortunately, normal values in blood pressure, central venous pressure, heart rate, and blood gases do not rule out tissue hypoxia or imbalances between whole-body oxygen supply and demand [2]. This discrepancy has led to increased interest in more direct indicators of adequacy of tissue oxygenation such as mixed and central venous oxygen saturations. Pulmonary artery catheterization allows obtaining true mixed venous oxygen saturation (SvO2) while measuring central venous oxygen saturation (ScvO2) via central venous catheter reflects principally the degree of oxygen extraction from the brain and the upper part of the body. This brief review discusses the role and limitations of SvO2 and ScvO2 as indicators of the adequacy of tissue oxygenation.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Marshall JC (2001) Inflammation, coagulopathy, and the pathogenesis of multiple organ dysfunction syndrome. Crit Care Med 29:S99–S106
Reinhart K (1989) Monitoring O2 transport and tissue oxygenation in critically ill patients. In: Reinhart K, Eyrich K (ed) Clinical aspects of O2 transport and tissue oxygenation. Springer, Berlin Heidelberg New York, pp 195–211
Reinhart K, Schäfer M, Rudolph T, Specht M (1989) Mixed venous oxygen saturation. Appl Cardiopulm Pathophysiol 2:315–325
Vincent JL, De Backer D (2004) Oxygen transport-the oxygen delivery controversy. Intensive Care Med 30:1990–1996
Scheinman MM, Brown MA, Rapaport E (1969) Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients. Circulation 40:165–172
Lee J, Wright F, Barber R, Stanley L (1972) Central venous oxygen saturation in shock: a study in man. Anesthesiology 36:472–478
Reinhart K, Kuhn HJ, Hartog C, Bredle DL (2004) Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med 30:1572–1578
Meier-Hellmann A, Specht M, Hannemann L, Hassel H, Bredle DL, Reinhart K (1996) Splanchnic blood flow is greater in septic shock treated with norepinephrine than in severe sepsis. Intensive Care Med 22:1354–1359
Edwards JD, Mayall RM (1998) Importance of the sampling site for measurement of mixed venous oxygen saturation in shock. Crit Care Med 26:1356–1360
Reinhart K, Rudolph T, Bredle DL, Hannemann L, Cain SM (1989) Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand. Chest 95:1216–1221
Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:1368–1377
Rivers EP, Rady MY, Martin GB, Fenn NM, Smithline HA, Alexander ME, Nowak RM (1992) Venous hyperoxia after cardiac arrest. Characterization of a defect in systemic oxygen utilization. Chest 102:1787–1793
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Bloos, F., Reinhart, K. (2009). Venous oximetry. In: Hedenstierna, G., Mancebo, J., Brochard, L., Pinsky, M. (eds) Applied Physiology in Intensive Care Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01769-8_13
Download citation
DOI: https://doi.org/10.1007/978-3-642-01769-8_13
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-01768-1
Online ISBN: 978-3-642-01769-8
eBook Packages: MedicineMedicine (R0)