Abstract
This chapter, appearing in the section on MRI Findings, Interpretation, and Management, reviews the issues relevant to benign MRI-guided biopsy results. The discussion includes challenges in assessing radiologic-pathologic concordance specific to MRI, approaches for discordant biopsy results, and a review of the literature on appropriate imaging follow-up recommendations for benign concordant MRI-guided breast biopsy results. High risk lesions from MRI-guided biopsy are addressed in a separate chapter.
Access provided by CONRICYT-eBooks. Download chapter PDF
Similar content being viewed by others
Keywords
- Benign
- MRI-guided biopsy
- Radiologic-pathologic concordance
- Discordance
- Management
- Recommendations
- Follow-up imaging
- ACR:
-
American College of Radiology
- BI-RADS®:
-
Breast Imaging-Reporting and Data System
- ER+:
-
Estrogen receptor-positive
- HER2:
-
Human epidermal growth factor receptor 2
- MRI:
-
Magnetic resonance imaging
- PACS:
-
Picture archiving and communication systems
- PPV:
-
Positive predictive value
- PR+:
-
Progesterone receptor-positive
1 Introduction
Breast MRI utilization is increasing in clinical practice in the United States. Nearly 11.5 breast MRI examinations per 1000 women undergoing breast imaging were reported to have occurred in 2009 [1]. Clinical indications for contrast-enhanced breast MRI include supplemental screening for women with greater than 20 % lifetime risk of breast cancer, preoperative planning for women with newly diagnosed breast cancer, evaluation of response to neoadjuvant chemotherapy, and occult primary tumor localization in women presenting with biopsy-proven metastatic axillary lymphadenopathy [2].
Breast MRI is the most sensitive modality for breast cancer detection [3]. When used as a supplement to mammography for high risk screening, the cancer detection rate increases from approximately 8.2 to 26.1 per 1000 women [4]. However, breast MRI is not a perfect test and its specificity is lower than its sensitivity due to overlapping imaging features of benign and malignant lesions [3]. For example, the current American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS®) practice benchmark for positive predictive value of biopsies performed (PPV3) is 20–50 % for breast MRI screening programs [5]. Thus, many biopsies will yield benign results. It is imperative that radiologists have a solid understanding of the management of benign results, including the assessment of adequate tissue sampling, the process for determining whether the histopathologic result appropriately explains the imaging finding, and recommendations for follow-up imaging. This chapter focuses on these important issues surrounding benign MRI-guided breast biopsy results. The management of high risk lesions identified at MRI-guided biopsy is not addressed in this chapter.
2 Radiologic-Pathologic Concordance for MRI-Guided Breast Biopsies
Percutaneous biopsy is preferred over needle localization and surgical excision for findings visualized only on MRI [6, 7]. If percutaneous biopsy results are benign and concordant, unnecessary surgical excisional biopsy and its associated greater cost, time, morbidity, and cosmetic changes can be avoided. For patients with malignant results, surgical planning can be optimized reducing the total number of surgeries required for complete breast cancer treatment. MRI-guided breast biopsy has been shown to be a safe alternative to MRI-guided wire localization and excisional biopsy with comparable diagnostic accuracy [8–11].
A critical component that is essential for robust diagnostic accuracy of MRI-guided breast biopsy procedures is determination of radiologic-pathologic concordance. A biopsy result is defined as concordant when the histopathology sufficiently explains the imaging findings that prompted the recommendation for biopsy (see Fig. 13.1) [12]. A discordant result is one in which the histopathology does not explain the imaging findings and most often occurs when a benign pathology is reported for a highly suspicious imaging finding.
The purpose of determining concordance is to minimize the potential for false-negative biopsies resulting from inadequate sampling or inaccurate targeting and to avoid a delayed diagnosis of cancer. The frequency of inadequate tissue sampling of MRI lesions has been reported as 6–14 % [13–15]. Use of vacuum-assisted devices, typically with 9 gauge needles, are encouraged which yield generous amounts of tissue for thorough histopathologic examination [7]. As for other breast imaging modalities, when a malignancy is detected within one year at the site of a benign MRI-guided biopsy it is considered a false-negative [5]. False-negative rates for MRI-guided breast biopsies range from 0.9 to 11.7 % [10, 13–17]. Accurate determination of a program’s false-negative biopsy rate is inherently challenging due to the potential lack of patient follow-up at the same institution. Audit data linkage with state or regional cancer registries can be helpful to improve the accuracy of false-negative biopsy rate.
Information used in determination of radiologic-pathologic concordance starts at the time of the diagnostic examination. A BI-RADS® assessment of 5 (highly suggestive of malignancy) indicates that a benign biopsy result should, in most instances, be deemed discordant. Furthermore, subcategorization of BI-RADS® 4 assessments into 4A, 4B, and 4C (low, moderate, and high suspicion for malignancy, respectively) is also informative. In contrast to mammography and ultrasound, subcategories for BI-RADS® 4 assessments are not included for MRI in the most current edition of the BI-RADS® Atlas [5]. However, subcategorization of BI-RADS® 4 assessments can be particularly useful for breast MRI radiologic-pathologic correlation because the level of concern for malignancy is more stratified. For example, a lesion with a 4C assessment that yields benign biopsy results should be reviewed with particular scrutiny. Particular benign pathologies that are well-known to present as suspicious imaging findings, such as fat necrosis, could be considered concordant in these instances.
Assessing the adequacy of tissue sampling at the time of biopsy also contributes to concordance determination. Immediate post-biopsy images are obtained and reviewed during the procedure to allow for adjustment and additional sampling if needed. Some practices perform a second injection of contrast to revisualize the lesion [11]. However, the presence of blood and air in the biopsy cavity frequently limits the utility of this approach.
Adequate communication with the interpreting pathologist is another key factor in optimizing radiologic-pathologic concordance. Inclusion of key clinical information, indication for biopsy, imaging features of the biopsied lesion, potential differential diagnoses based on imaging, and the BI-RADS® assessment on the pathology requisition form provides a quick and focused method for conveying this important information. For complicated cases or those with unusual or unexpected histopathologic results, the pathologist may contact the radiologist who performed the procedure with specific questions before issuing their final report. Being available and engaged in these conversations further improves radiologic-pathologic concordance and strengthens the multi-disciplinary approach to patient care.
Once biopsy results are issued by pathology, the methods used for assessing radiologic-pathologic concordance vary by institution and practice type. One approach involves a dedicated multidisciplinary clinical conference. The radiologist presents the clinical history and imaging studies performed before, during, and after the biopsy to demonstrate initial findings and level of suspicion for malignancy, adequate targeting and sampling, and appropriate marker clip placement. This is followed by presentation of the histopathologic results by the pathologist. Group consensus is reached regarding concordance, and management recommendations are determined. This method can foster interdepartmental professional relationships and can be achieved in this modern electronic era through remote Picture archiving and communication systems (PACS) and scanned histology slides through programs available on the internet and/or video-conferencing. An approach such as this may be more amenable to implementation at teaching institutions. For settings in which it might not be practical for a physical radiology-pathology correlation conference such as high-volume clinical services, the radiologist may perform dedicated review of imaging findings independently or together with other radiologists in the group using the written pathology report.
Determining radiologic-pathologic concordance relies upon knowledge of the acceptable histopathology for particular imaging findings. For breast MRI, most of the research has focused on the imaging features that are predictive of malignancy. For example, foci have been shown to have lower probabilities of malignancy compared to masses or non-mass enhancement [18]. For masses on MRI, margins have been found to be an important imaging predictor [19, 20]. However, there are relatively few data regarding the MRI features that are associated with particular benign histopathology outcomes. Biopsies of breast MRI findings have been shown to result in a spectrum of benign, concordant histopathology results. These include nonspecific findings such as fibrocystic change, sclerosing adenosis, fibrosis, pseudoangiomatous stromal hyperplasia, and normal breast parenchyma [20, 21]. More specific benign and concordant results include fibroadenoma, papilloma, and lymph node. In general, nonspecific results have been more frequently associated with non-mass enhancement [20, 21], but further studies are warranted to clarify acceptable MRI lesion and histopathology outcomes.
Once radiologic-pathologic correlation has been performed and concordance has been determined, management recommendations are made and communicated to the referring physician and the patient. Patients with malignant results are referred to a breast surgeon and/or medical oncologist for treatment. Management of patients with benign results that are discordant and those with benign results that are concordant are discussed in the subsequent sections of this chapter. Importantly, an addendum is made to the original biopsy report with the histopathologic results, radiologic-pathologic concordance, and management recommendations.
Practice guidelines regarding MRI-guided breast biopsy procedures have been published by the American College of Radiology (ACR) and as a report from a European interdisciplinary consensus meeting [6, 7]. The ACR states that the physician who performed the procedure “is responsible for obtaining results of the histopathologic sampling to determine if the lesion has been adequately biopsied and is concordant or discordant with the imaging findings” [7]. The European interdisciplinary consensus report recommends “all available clinical and imaging information and VAB results be compared and discussed in an interdisciplinary conference to achieve a consensus recommendation in each case” [6]. These reports reinforce the importance of assessing concordance.
For several reasons, radiologic-pathologic concordance is more challenging for MRI-guided biopsies compared to stereotactic- and ultrasound-guided biopsies. First, there is no specimen radiograph to confirm adequate sampling due to the lack of tissue enhancement ex vivo. Second, there is no “real-time” visualization of the needle at the time of tissue sampling since the biopsy is performed when the patient is outside of the magnet. Determining whether the targeted finding has been appropriately sampled on post-biopsy MRI sequences has limitations as lesions with wash-out contrast kinetics become less conspicuous over time while enhancement of normal breast parenchyma increases. Also, lesions can be obscured by hematoma and air on post-biopsy sequences. These factors together with the higher pre-test probability of malignancy in women undergoing breast MRI support adopting a careful approach to radiologic-pathologic concordance to avoid a delayed cancer diagnosis.
3 Discordant MRI-Guided Breast Biopsy Results
A discordant biopsy result is one in which the histopathology does not sufficiently explain the imaging findings [12]. The discordance rates for MRI-guided breast biopsies using vacuum-assisted devices range from 0 to 9 % [9, 10, 22–26]. The rates of discordant biopsies are higher for MRI-guided biopsies compared with stereotactic- or ultrasound-guided biopsies (approximately 3 %) [12, 24]. Interestingly, discordance has not been shown to occur more often with BI-RADS® category 5 compared with category 4 lesions or to occur more often for radiologists with less experience with MRI-guided biopsies, factors that are known to affect discordance rates for stereotactic- and ultrasound-guided biopsies [24].
Further tissue sampling is warranted in cases of discordant MRI-guided biopsy results (see Fig. 13.2) [6, 7]. Options include repeat MRI-guided biopsy or surgical excision. The method used for preoperative wire localization prior to surgical excision includes mammographic-guidance if the marker clip placement is deemed appropriate. If there is significant clip displacement and mammographic landmarks are lacking, MRI-guided wire localization can be performed. The malignancy rate for discordant lesions that subsequently undergo surgical excision is 30–50 % [22, 24]. Thus, appropriate recognition and management of discordant lesions is clinically significant.
For discordant lesions undergoing repeat MRI-guided biopsy, radiologic-pathologic concordance should again be determined. Similarly, review of final histopathologic results for cases recommended for surgical excision are informative and recommended [6]. Important factors to note include the presence or absence of prior biopsy site changes in the excised specimen and whether any residual lesion exists in the specimen as well as final histopathologic size since small lesions may be completely removed during the biopsy procedure.
4 Management Recommendations for Patients with Benign Concordant Biopsy Results
Due to the challenges involved in confirming adequate sampling at the time of the MRI-guided biopsy procedure, a follow-up MRI examination is recommended for patients with benign concordant biopsy results to identify any delayed false-negative cases. The overall cancer yield at follow up-MRI has been reported as 0.9–2.3 % [13, 16, 17, 20]. The recommendation for follow-up MRI also includes when biopsies of suspicious MRI findings are performed using ultrasound guidance of presumed correlates identified on MRI-targeted ultrasound. The rationale for this recommendation is based on the results of Meissnitzer et al. which demonstrated that the presumed correlate on ultrasound did not correspond to the MRI finding of concern in 12.5 % of cases (10/80) with 5 cancers diagnosed in 9 lesions that underwent subsequent MRI-guided biopsy [27].
Ideally, the follow-up examination should be performed at the same institution using the same imaging acquisition protocol to best evaluate for potential interval change. Two studies have described an increase in the largest lesion dimension by 10 % as evidence of an interval size change, but there is no standardized definition for what constitutes clinically significant change [13, 16]. Lesions demonstrating concerning enlargement or development of more suspicious imaging features should undergo repeat biopsy or surgical excision (see Fig. 13.3) [16]. If the biopsied lesion decreases in size or resolves completely on the follow-up MRI, adequate sampling is confirmed and no further surveillance is required [15, 16]. This approach is supported by data of Dratwa et al. that showed no interval change at a 12 month follow-up MRI for 117 benign concordant lesions that had decreased or resolved at the initial 6 month examination [20].
There is currently no consensus on the optimal interval for the initial follow-up MRI nor the duration of follow-up imaging. In general, initial follow-up MRI is performed at 6–12 months after the index MRI [7, 28]. Several studies have been reported that recommend 6 month follow-up for all benign concordant lesions [9, 14, 15, 23, 25, 26, 28, 29]. Others base the follow-up interval on the specificity of the histopathologic result. For example, follow-up MRI is recommended at 6 months and 12 months after a nonspecific benign concordant biopsy result and at 12 months for a specific result such as a fibroadenoma, fat necrosis, or benign lymph node [11]. One study proposes that specific benign concordant diagnoses may not require further follow-up MRI [10]. Further evidence is necessary to support guidelines for optimal follow-up MRI interval.
For lesions that are stable on the initial follow-up MRI (see Fig. 13.4), recommendations for subsequent imaging are mixed. Some recommend returning to routine screening [9]. Given the potential uncertainty of adequate sampling during the biopsy procedure, others recommend continued follow-up MRI in 6–12 months [15, 16].
Studies investigating the short-term and long-term outcomes of benign concordant biopsy results are increasing in number [13–17]. Li et al. reported results from a retrospective review of 177 lesions with benign concordant MRI-guided biopsy results. Although the follow-up recommendations varied at the discretion of the procedure radiologist, all cases had follow-up MRI within 12 months [13]. Most of the lesions (155/177) had decreased in size or resolved at the initial follow-up MRI with no subsequent cancer diagnosis. Seventeen lesions were felt to warrant a second biopsy and four were found to be cancers, for an overall cancer yield of 2.3 % (4/177). All cancers detected were ≤1.0 cm in pathologic size, lymph node negative, and occurred in women with a personal history of breast cancer. Two cancers presented as enlarging non-mass enhancement at 6 and 12 months after the initial benign concordant biopsies. Given the potential for detection of false negatives, a 6 month follow-up interval was deemed most appropriate by this research group [30, 31].
A recent retrospective study by Dratwa et al. reported that 1.7 % (2/119) of benign concordant lesions displayed interval increase in size at the 6 month follow-up MRI [20]. Both lesions underwent surgical excision and yielded malignancy. These results also support an initial 6 month follow-up MRI recommendation.
While a 6 month follow-up MRI is a conservative method for minimizing delayed false-negative biopsies, some disadvantages exist to this approach. New lesions requiring further workup can occur on the follow-up MRI. While new cancers can be discovered (3/12, 25 %) as in Li et al. [13], additional false-positive findings may also occur. Furthermore, patient compliance is integral for the effectiveness of short-interval follow-up imaging. Rates of compliance for 6 month follow-up MRI are 43–63 % [16, 17, 29, 32]. Women with the indication of high-risk screening for the initial MRI are more likely to return for follow-up imaging compared to women having MRI for problem-solving or for extent of disease [17]. Women referred from outside institutions are less likely to be compliant with recommended follow-up compared to those within the same institution [32]. Potential deterrents to compliance include the relatively high cost and variable insurance coverage for short-interval follow-up breast MRI.
Two studies have been subsequently published suggesting that 6 month follow-up MRI may not be necessary and that initial MRI follow-up at 12 months is acceptable [16, 17]. Shaylor et al. reported results from a retrospective review of 113 benign concordant lesions with follow-up MRI [17]. One malignancy (ductal carcinoma in situ) was detected 2 years after the initial benign biopsy for an overall cancer yield of 0.9 % (1/113). Since no cancers were detected at the 6 month follow-up MRI examination, the authors propose that annual screening MRI is a reasonable approach.
Similarly, results from Lee et al. suggest that the initial follow-up MRI examination can be deferred to 12 months without reducing cancer detection rates [16]. This study was a retrospective review of 85 eligible cases of benign concordant MRI-guided biopsies with a minimal follow-up of 2 years. Most of the lesions (57/70) had decreased in size or resolved at the initial 6 month follow-up MRI and all of these were confirmed as benign with ≥2 years of imaging and clinical follow-up. No cancers were detected at the 6-month or 12-month follow-up MRI. One malignancy (invasive ductal carcinoma with a micrometastatic sentinel lymph node) was detected after the biopsied mass enlarged at 24 months post biopsy despite being stable on the MRI performed at 10 months. The overall cancer yield was 1.2 % (1/85). The authors concluded that deferring the initial follow-up MRI to 12 months after biopsy is acceptable and that follow-MRI examinations should be continued for a minimum of 2 years to confirm benignity.
Some studies have reported no malignancies during their follow-up imaging period, also supporting that short-interval follow-up MRI may not be necessary. Perlet et al. reported results from a multicenter European study of 316 of 362 benign MRI-guided biopsies followed for a median of 32 months [11]. Subsequent repeat biopsy occurred in 3 patients; however, no malignancies were detected. Similarly, no cancers were found at follow-up MRI in 12 of 20 benign lesions followed for a mean of 7.5 months (range 3–14 months) reported by Hauth et al. or during the follow-up period of Bahrs et al. (mean 13 months; range 5–22 months) [14, 15]. It is important to note that these latter two studies performed immediate follow-up MRI 24–48 h after biopsy and resampled any lesions that appeared unchanged and that the study reported by Perlet et al. performed a second contrast injection at the time of biopsy and resampled any lesions remaining visible with minimal to no change. These important technical differences limit the generalizability of the follow-up results. Recently, Rauch et al. reported no malignancies during follow-up of 133 of 218 benign concordant lesions for a mean of 39 months (range 6–69 months) [29]. The biopsy protocol performed by this group more closely reflects the majority of practices in the United States which typically do not perform a second contrast injection or immediate follow-up MRI 24–48 h after biopsy.
Overall, a follow-up MRI in 6–12 months is typically warranted after benign concordant MRI-guided biopsies, particularly for histopathology results that are nonspecific [7]. In the future, imaging follow-up in this scenario may evolve to be less intensive, as has occurred for other image-guided percutaneous biopsies [33–36]. It is important, however, to recognize that patients undergoing MRI-guided biopsies have a higher risk of malignancy than those undergoing stereotactic- or ultrasound-guided biopsies. Accordingly, management recommendations should be based on the scientific evidence available and should be specific to the patient populations undergoing MRI-guided biopsies.
5 Summary
Clinical issues relevant to the care of patients undergoing MRI-guided biopsy have been reviewed. Assessment of radiologic-pathologic concordance is critical in cases of benign results to avoid a delayed diagnosis of cancer and can be more challenging for MRI-guided biopsies compared to other image-guided techniques. Discordant biopsy results are typically managed with repeat biopsy or MRI-guided wire localization and surgical excision. Evidence-based recommendations for optimal follow-up of benign concordant MRI-guided breast biopsy results continue to evolve.
References
Wernli KJ, DeMartini WB, Ichikawa L, Lehman CD, Onega T, Kerlikowske K, et al. Patterns of breast magnetic resonance imaging use in community practice. JAMA Intern Med. 2014;174(1):125–32.
ACR Practice Parameter for the Performance of Contrast-Enhanced Magnetic Resonance Imaging (MRI) of the Breast. 2014. Available from: http://www.acr.org/~/media/2a0eb28eb59041e2825179afb72ef624.pdf. Accessed 22 Dec 2015.
DeMartini W, Lehman C. A review of current evidence-based clinical applications for breast magnetic resonance imaging. Top Magn Reson Imaging. 2008;19(3):143–50.
Berg WA, Zhang Z, Lehrer D, Jong RA, Pisano ED, Barr RG, et al. Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk. JAMA. 2012;307(13):1394–404.
D’Orsi CJ, Sickles EA, Mendelson EB, Morris EA. ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System. 5th ed. Reston: American College of Radiology; 2013.
Heywang-Kobrunner SH, Sinnatamby R, Lebeau A, Lebrecht A, Britton PD, Schreer I. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting. Eur J Radiol. 2009;72(2):289–94.
ACR Practice Parameter for the Performance of Magnetic Resonance Imaging-Guided Breast Interventional Procedures. 2014. Available from: http://www.acr.org/~/media/ACR/Documents/PGTS/guidelines/MRI_Guided_Breast.pdf. Accessed 21 Dec 2015.
Liberman L, Morris EA, Dershaw DD, Thornton CM, Van Zee KJ, Tan LK. Fast MRI-guided vacuum-assisted breast biopsy: initial experience. AJR Am J Roentgenol. 2003;181(5):1283–93.
Lehman CD, Deperi ER, Peacock S, McDonough MD, Demartini WB, Shook J. Clinical experience with MRI-guided vacuum-assisted breast biopsy. AJR Am J Roentgenol. 2005;184(6):1782–7.
Orel SG, Rosen M, Mies C, Schnall MD. MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience. Radiology. 2006;238(1):54–61.
Perlet C, Heywang-Kobrunner SH, Heinig A, Sittek H, Casselman J, Anderson I, et al. Magnetic resonance-guided, vacuum-assisted breast biopsy: results from a European multicenter study of 538 lesions. Cancer. 2006;106(5):982–90.
Liberman L, Drotman M, Morris EA, LaTrenta LR, Abramson AF, Zakowski MF, et al. Imaging-histologic discordance at percutaneous breast biopsy. Cancer. 2000;89(12):2538–46.
Li J, Dershaw DD, Lee CH, Kaplan J, Morris EA. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy. AJR Am J Roentgenol. 2009;193(3):850–5.
Hauth EA, Jaeger HJ, Lubnau J, Maderwald S, Otterbach F, Kimmig R, et al. MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h. Eur Radiol. 2008;18(1):168–76.
Bahrs SD, Hattermann V, Preibsch H, Hahn M, Staebler A, Claussen CD, et al. MR imaging-guided vacuum-assisted breast biopsy: reduction of false-negative biopsies by short-term control MRI 24-48 h after biopsy. Clin Radiol. 2014;69(7):695–702.
Lee SJ, Mahoney MC, Redus Z. The management of benign concordant MRI-guided breast biopsies: lessons learned. Breast J. 2015;21(6):665–8.
Shaylor SD, Heller SL, Melsaether AN, Gupta D, Gupta A, Babb J, et al. Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy–is it worthwhile? Eur Radiol. 2014;24(6):1176–85.
Mahoney MC, Gatsonis C, Hanna L, DeMartini WB, Lehman C. Positive predictive value of BI-RADS MR imaging. Radiology. 2012;264(1):51–8.
Gutierrez RL, DeMartini WB, Eby PR, Kurland BF, Peacock S, Lehman CD. BI-RADS lesion characteristics predict likelihood of malignancy in breast MRI for masses but not for nonmasslike enhancement. AJR Am J Roentgenol. 2009;193(4):994–1000.
Dratwa C, Jalaguier-Coudray A, Thomassin-Piana J, Gonin J, Chopier J, Antoine M, et al. Breast MR biopsy: pathological and radiological correlation. Eur Radiol. 2015;26(8):2510–9 [Epub ahead of print].
Johnson KS, Baker JA, Lee SS, Soo MS. Suspicious breast lesions detected at 3.0 T magnetic resonance imaging: clinical and histological outcomes. Acad Radiol. 2012;19(6):667–74.
Liberman L, Bracero N, Morris E, Thornton C, Dershaw DD. MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience. AJR Am J Roentgenol. 2005;185(1):183–93.
Mahoney MC. Initial clinical experience with a new MRI vacuum-assisted breast biopsy device. J Magn Reson Imaging. 2008;28(4):900–5.
Lee JM, Kaplan JB, Murray MP, Bartella L, Morris EA, Joo S, et al. Imaging histologic discordance at MRI-guided 9-gauge vacuum-assisted breast biopsy. AJR Am J Roentgenol. 2007;189(4):852–9.
Ghate SV, Rosen EL, Soo MS, Baker JA. MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system. AJR Am J Roentgenol. 2006;186(6):1733–6.
Gebauer B, Bostanjoglo M, Moesta KT, Schneider W, Schlag PM, Felix R. Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device. Acta Radiol. 2006;47(9):907–13.
Meissnitzer M, Dershaw DD, Lee CH, Morris EA. Targeted ultrasound of the breast in women with abnormal MRI findings for whom biopsy has been recommended. AJR Am J Roentgenol. 2009;193(4):1025–9.
Heywang-Kobrunner SH, Heinig A, Schaumloffel U, Viehweg P, Buchmann J, Lampe D, et al. MR-guided percutaneous excisional and incisional biopsy of breast lesions. Eur Radiol. 1999;9(8):1656–65.
Rauch GM, Dogan BE, Smith TB, Liu P, Yang WT. Outcome analysis of 9-gauge MRI-guided vacuum-assisted core needle breast biopsies. AJR Am J Roentgenol. 2012;198(2):292–9.
Brennan SB, Sung J, Lee C, Dershaw DD, Morris E. Lessons learned from MR-guided breast-biopsy. Eur J Radiol. 2012;81(Suppl 1):S10.
Sung JS, Lee CH, Morris EA, Comstock CE, Dershaw DD. Patient follow-up after concordant histologically benign imaging-guided biopsy of MRI-detected lesions. AJR Am J Roentgenol. 2012;198(6):1464–9.
Thompson MO, Lipson J, Daniel B, Harrigal C, Mullarkey P, Pal S, et al. Why are patients noncompliant with follow-up recommendations after MRI-guided core needle biopsy of suspicious breast lesions? AJR Am J Roentgenol. 2013;201(6):1391–400.
Salkowski LR, Fowler AM, Burnside ES, Sisney GA. Utility of 6-month follow-up imaging after a concordant benign breast biopsy result. Radiology. 2011;258(2):380–7.
Johnson JM, Johnson AK, O’Meara ES, Miglioretti DL, Geller BM, Hotaling EN, et al. Breast cancer detection with short-interval follow-up compared with return to annual screening in patients with benign stereotactic or US-guided breast biopsy results. Radiology. 2015;275(1):54–60.
Manjoros DT, Collett AE, Alberty-Oller JJ, Frazier TG, Barrio AV. The value of 6-month interval imaging after benign radiologic-pathologic concordant minimally invasive breast biopsy. Ann Surg Oncol. 2013;20(10):3163–8.
Youk JH, Jung I, Kim EK, Kim MJ, Son EJ, Moon HJ, et al. US follow-up protocol in concordant benign result after US-guided 14-gauge core needle breast biopsy. Breast Cancer Res Treat. 2012;132(3):1089–97.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Fowler, A.M., DeMartini, W.B. (2017). Breast MRI and the Benign Breast Biopsy. In: Heller, S., Moy, L. (eds) Breast Oncology: Techniques, Indications, and Interpretation. Springer, Cham. https://doi.org/10.1007/978-3-319-42563-4_13
Download citation
DOI: https://doi.org/10.1007/978-3-319-42563-4_13
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-42561-0
Online ISBN: 978-3-319-42563-4
eBook Packages: MedicineMedicine (R0)