Abstract
Alloplastic reconstruction has evolved as the most popular technique for post-mastectomy breast reconstruction for the appropriate patient population. Acellular dermal matrices (ADMs) offer many advantages in optimizing aesthetic results and have gained significant popularity in recent years. Their use as an inferolateral sling has expanded the plastic surgeon’s armamentarium to include immediate direct-to-implant reconstructions. However, ADMs have been reported to result in increased complication rates, particularly with regard to infection and seroma formation. In addition, they are costly to manufacture and produce. Therefore, alternatives to ADMs are discussed that may serve to lower complication rates and cost without sacrificing aesthetic results.
Access provided by Autonomous University of Puebla. Download chapter PDF
Similar content being viewed by others
Keywords
- Breast Reconstruction
- Acellular Dermal Matrix
- Absorbable Mesh
- Complication Profile
- Trimethylene Carbonate
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
1 Introduction
Implant-based reconstruction remains the most commonly employed technique for post-mastectomy breast reconstruction in appropriate patients. In an effort to improve the aesthetic results of and minimize morbidity from total submuscular coverage, the use of acellular dermal matrices (ADMs) as an inferolateral sling has gained significant popularity in the last decade, arguably becoming the standard of care. Proponents of this technique report increased intraoperative fill volumes, more defined inframammary and lateral mammary folds, and stabilization of the pectoralis major without window-shading during expansion.
As indications for nipple-sparing and skin-sparing mastectomies broaden, so has their commonality. For these patients, ADMs have played a fundamental role in the development of immediate single-stage direct-to-implant reconstruction, expanding our implant-based reconstructive options.
Although many consider the usage of ADMs as progress in the authors’ technique, they are not without their flaws. Biologic materials are limited in availability and expensive to harvest and produce, resulting in significantly higher costs to an already burdened healthcare system. Within the literature, controversy exists as to whether the incidence of seroma and/or infection is increased with the use of ADMs. As a result, many have sought alternatives to ADMs in an effort to find a more cost-effective and safer material, without compromising aesthetic results. An expanding number of synthetic, absorbable meshes have been reportedly used with success. In a recently published experience, polyglactin 910 (Vicryl; Ethicon, Inc., Somerville, N.J.) has served as an ideal ADM substitute.
2 Technique
The inferolateral sling pectoralis extension technique for absorbable mesh is very similar to that for ADMs. Likewise, absorbable meshes are appropriate to use in either single or two-stage implant based reconstruction. Typically, the determination of direct-to-implant versus staged reconstruction will be based on mastectomy flap viability, degree of mastectomy skin sparing, and relative desired postoperative breast volume. Careful examination of the skin flaps and laser angiography, when available, guide the assessment. In either technique, a subpectoral pocket is dissected. The pectoralis major is released from its inferior costal insertions to their junction at the sternum where the direction of muscle fibers becomes more transversely oriented.
3 Direct-to-Implant Reconstruction
As described by Tessler et al. [1], for single-stage reconstructions, a saline sizer is selected based on the mastectomy specimen weight and breast base width. The sizer is inserted in the partial subpectoral pocket and inflated to the desired volume. The outline of the implant is marked to assist appropriate tacking of the absorbable mesh. The mesh is secured to the inferior and lateral mammary folds using absorbable sutures (Fig. 35.1). The sizer is reinserted and the skin flaps temporarily stapled closed. The patient is brought into the seated position to ensure symmetry, good contour, and proper fold placement. The patient is returned to the supine position, the sizer removed, and the final implant inserted with a minimal touch technique. The superior edge of the absorbable mesh is secured to the inferior edge of the pectoralis with absorbable sutures (Fig. 35.2). Two drains are tunnel subcutaneously and placed in the subcutaneous and subpectoral spaces. Hemostasis is ensured and the skin is closed. A loose surgical bra is applied.
4 Two-Staged Implant-Based Reconstruction
In two-staged, tissue expander to implant reconstruction, the technique is essentially identical to that of ADM. An inferolateral mesh sling is sutured to the inferior edge of the released pectoralis major muscle, serving as a pectoral extension. The mesh is then sutured inferior-laterally to define the neo-inframammary fold and lateral breast border. The tissue expander is placed in the subpectoral/mesh plane. Drains are only placed in the subcutaneous plane, as the mesh does not serve as a water-tight barrier dividing the space into separate pre and subpectoral planes. In-office expansion is initiated as early as 3 weeks.
5 Discussion
5.1 Benefits of ADM
ADMs offer significant improvements to implant-based reconstruction in both single and two-stage procedures. Reported advantages over traditional total submuscular coverage include improved expansion of the lower pole allowing for increased intraoperative fill, better pocket control, enhanced definition of the inframammary and lateral mammary folds, and faster time to implant exchange [2, 3]. In addition, postoperative pain and hematoma rates may be reduced due to a lessened musculofascial dissection, particularly of the serratus which has a broad insertion and is transected by multiple perforating intercostals nerves. Several histologic and clinical studies have reported less significant capsule formation with the use of ADMs [4].
5.2 Potential Disadvantages of ADM
Several large-scale studies reveal a complication profile similar to non-ADM based reconstruction [5]. However, the data regarding their complication profile, particularly with respect to infection and seroma, remain conflicting. This is likely secondary to significant discrepancies in technique, materials, and definitions of complications. Antony et al. [6] reported a twofold increase in total complication rates with ADM in immediate two-stage breast reconstructions. The ADM group was found to have a statistically significant higher seroma rate (7.2 % vs. 1.6 %) and reconstructive failure (5.9 % vs. 1.9 %) when compared to non-ADM reconstructions. Although the reconstructive failures were most commonly due to infection, the difference in infection rate itself was not found to be statistically significant (3.3 % vs. 1.3 %) potentially highlighting an insufficient sample size. In a large, consecutive series of tissue-expander/implant-based immediate breast reconstructions, Chun et al. [7] used a multiple regression model to find an approximately fourfold increase in seroma and infection in the ADM group. Weichman et al. [8] reported consistent findings with another large, single-institution population undergoing two-stage tissue expander breast reconstruction. Major complications were increased in the ADM group (15.3 % vs. 5.4 %). These complications included infection requiring intravenous antibiotics (8.6 % vs. 2.7 %), flap necrosis requiring excision (6.7 % vs. 2.7 %), and explantation of the tissue expander (7.7 % vs. 2.7 %). Using an animal model for bacterial adherence, Liao et al. [9] found significantly higher rates of biofilm formation in two commonly used ADM products as compared to polypropylene and polyglactin 910, potentially explaining higher infection rates and need for explantation given antibiotic resistance [9].
Beyond concerns about complication rates, ADMs have been found to have significantly variable elastic properties among distinct donors [10]. The implications with regard to the effect on symmetry or long-term support have yet to be determined.
5.3 Financial Implications of Use of ADM
Regardless of these potential disadvantages, ADMs, by their nature, are costly to produce and may not be readily available. In fact, the most commonly used material and size combination carries a hefty retail price of $4890 per piece, or approximately $26 per square centimeter. With rapidly rising hospital costs, profound efforts are being made to implement cost-effective methods. Consequently, financial concerns have been a major driving force in the quest to find more cost-effective materials with equal or better results and complication profiles. Ideal material characteristics are listed in Table 35.1.
6 Absorbable Vicryl Mesh
Although use of absorbable mesh represents a novel technique for implant-based breast reconstruction, preliminary results have been promising. As per Tessler et al.’s [1] experience, Vicryl mesh has yielded a cost-effective material (approximately $200 per bilateral case) that produces excellent aesthetic outcomes with a low complication profile. In 50 patients undergoing 76 breast reconstructions, a less than 7 % total complication rate was found, with average follow-up of 1.2 years. No implant bottoming-out or malposition was noted postoperatively, despite using an extensive range of implant sizes. During revisional or secondary surgery, capsule formation was found to be similar to that of a primary breast augmentation capsule.
7 Other Materials
Undoubtedly, other materials will emerge as feasible non-ADM alternatives. TIGR Matrix (Novus Scientific; Singapore), a long-term absorbable synthetic mesh with dual-stage resorption, has been successfully used in immediate breast reconstruction [11]. Fast-degrading fiber is a copolymer between glycolide and trimethylene carbonate, resulting in total resorption within 4 months. The slow-degrading fiber is essentially a copolymer of lactide and trimethylene carbonate that keeps mechanical strength for up to 9 months. With degradation, the mesh becomes softer and more pliable.
The Seri surgical scaffold (Allergan, Inc.; Irvine, C.A.) is a knitted material composed of silk-derived fibroin, sourced from the silkworm that being explored as yet another alternative. It functions as a long-term resorbable mesh, providing support for up to 24 months as tissue ingrowth occurs. Animal studies are promising with regard to maintaining mechanical strength, although published human data has yet to be concluded.
8 Conclusions
As the field of non-ADM alternatives expands, large, prospective studies need to be performed in order to further delineate their respective advantages and disadvantages. Preliminary data suggests that equivocal results can likely be achieved at a lower cost and with a potentially lower complication profile. The recent use of products like absorbable mesh and silkworm products are a demonstration of this effort.
References
Tessler O, Reish RG, Maman DY, Smith BL, Austen WG Jr (2014) Beyond biologics: absorbable mesh as a low-cost, low-complication sling for implant-based breast reconstruction. Plast Reconstr Surg 133(2):90e–99e
Spear SL, Parikh PM, Reisin E, Menon NG (2008) Acellular dermis-assisted breast reconstruction. Aesthetic Plast Surg 32(3):418–425
Breuing KH, Colwell AS (2007) Inferolateral AlloDerm hammock for implant coverage in breast reconstruction. Ann Plast Surg 59(3):250–255
Cheng A, Lakhiani C, Saint-Cyr M (2013) Treatment of capsular contracture using complete implant coverage by acellular dermal matrix: a novel technique. Plast Reconstr Surg 132(3):519–529
Colwell AS, Damjanovic B, Zahedi B, Medford-Davis L, Herti C, Austen WG Jr (2011) Retrospective review of 331 consecutive immediate single-stage implant reconstructions with acellular dermal matrix: indications, complications, trends, and costs. Plast Reconstr Surg 128(6):1170–1178
Antony AK, McCarthy CM, Cordeiro PG, Mehrara BJ, Pusic AL, Teo EH, Arriaga AF, Disa JJ (2010) Acellular human dermis implantation in 153 immediate two-stage tissue expander breast reconstructions: determining the incidence and significant predictors of complications. Plast Reconstr Surg 125(6):1606–1614
Chun YS, Verma K, Rosen H, Lipsitz S, Morris D, Kenney P, Eriksson E (2010) Implant-based breast reconstruction using acellular dermal matrix and the risk of postoperative complications. Plast Reconstr Surg 125(2):429–436
Weichman KE, Wilson SC, Weinstein AL, Hazen A, Levine JP, Choi M, Karp NS (2012) The use of acellular dermal matrix in immediate two-stage tissue expander breast reconstruction. Plast Reconstr Surg 129(5):1049–1058
Nyame TT, Lemon KP, Kolter R, Liao EC (2011) High-throughput assay for bacterial adhesion on acellular dermal matrices and synthetic surgical materials. Plast Reconstr Surg 128(5):1061–1068
Craft RO, Rebecca AM, Flahive C, Casey WJ 3rd, Dueck A, Harold KL (2011) Does size matter? Technical considerations of a regenerative tissue matrix for use in reconstructive surgery. Can J Plast Surg 19(2):51–52
Becker H, Lind JG 2nd (2013) The use of synthetic mesh in reconstructive, revision, and cosmetic breast surgery. Aesethet Plast Surg 37(5):914–921
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Sailon, A.M., Austen, W.G., Maman, D.Y. (2016). Alternatives to Acellular Dermal Matrix for Implant-Based Breast Reconstruction. In: Shiffman, M. (eds) Breast Reconstruction. Springer, Cham. https://doi.org/10.1007/978-3-319-18726-6_35
Download citation
DOI: https://doi.org/10.1007/978-3-319-18726-6_35
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-18725-9
Online ISBN: 978-3-319-18726-6
eBook Packages: MedicineMedicine (R0)