Abstract
The calibration of an inertial measurement unit (IMU), which could have noisy and inaccurate output, is usually made with expensive mechanical platforms. In this paper, the calibration is performed by fixing the IMU to the extremity of a low-cost pendulum, driven by free-fall motion. The theoretical IMU motion is estimated by the pendulum motion, modeled with kinetic and viscous friction whose values are experimentally determined. The calibration procedure is easy and relatively fast, since possible assembly errors of the IMU on the pendulum are mitigated: the calibration parameters of sensors are not affected by orientation errors up to 10° between the IMU and the pendulum.
The results of the proposed calibration approach are compared with the output of a commercial calibrated IMU, performing slow-rotation movements with a robotic arm. The results validate the proposed calibration method as a reliable and low-cost procedure.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., Stricker, D.: Survey of motion tracking methods based on inertial sensors: a focus on upper limb human motion. Sensors 17(6), 1257 (2017)
Ricci, L., Taffoni, F., Formica, D.: On the orientation error of IMU: investigating static and dynamic accuracy targeting human motion. PLoS ONE 11(9), e0161940 (2016)
Ferraris, F., Gorini, I., Grimaldi, U., Parvis, M.: Calibration of three-axial rate gyros without angular velocity standards. Sens. Actuators 42, 446–449 (1994)
Olivares Vicente, A., Olivares, G., Gorriz, J., Ramírez, J.: High-efficiency low-cost accelerometer-aided gyroscope calibration. In: Proceedings of the International Symposium on Test and Measurement, pp. 354–360 (2010)
Choi, K., Jang, S., Kim, Y.: Calibration of inertial measurement units using pendulum motion. Int. J. Aeronaut. Space Sci. 11, 234–239 (2010)
Skog I., Händel, P.: Calibration of a MEMS inertial measurement unit. In: XVII IMEKO World Congress Metrology for a Sustainable Development (2006)
Qureshi, U., Golnaraghi, F.: An algorithm for the in-field calibration of a MEMS IMU. IEEE Sens. J. 17(22), 7479–7486 (2017)
Piatkowski, T., Wolski, M.: Verification of the friction coefficients determining method for Froude pendulum self-excited vibrations. In: AIP Conference Proceedings, vol. 1822, p. 020012 (2017)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 CISM International Centre for Mechanical Sciences
About this paper
Cite this paper
Avallone, G., Agostini, L., Conconi, M., Parenti-Castelli, V., Vertechy, R., Sancisi, N. (2022). Low-Cost Gyroscope and Accelerometer Calibration with Free Fall Pendulum Motion: Results and Sensitivity. In: Kecskeméthy, A., Parenti-Castelli, V. (eds) ROMANSY 24 - Robot Design, Dynamics and Control. ROMANSY 2022. CISM International Centre for Mechanical Sciences, vol 606. Springer, Cham. https://doi.org/10.1007/978-3-031-06409-8_15
Download citation
DOI: https://doi.org/10.1007/978-3-031-06409-8_15
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-06408-1
Online ISBN: 978-3-031-06409-8
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)