Abstract
By analyzing the national normative and technical requirements of the lightning protection systems it seeing that there is a demand for an extra layer of protection measures from a direct lightning strike or voltage induction by a remote one. Protective devices and charts of their settings need to be determined in order to achieve that. Information and communication systems as well as their components have protection centered around counteracting thunderstorms in the environment. Ukraine’s standardization implements the recommended methods of calculation and protecting schemes from impulsive overvoltage. Authors has led a thorough analysis is made for the case of existing protectively-switching devices. A comparison of low-voltage electric networks surge protection devices in combination with park protection devices at defective contact connections was performed. The sensitivity limits for the proper operation of protective devices are determined as furthermore performed an analysis on signals indicating the reception of information on an occurrence of a defective contact connection. This, overall, displays the necessity of applying measurements means against impulse overvoltage in information and communication circuits. Those means control detection and are capable of fixing impulse irregularities from the usual form of network voltage. Constructing of measuring instruments with high metrological characteristics for impulse disturbances in information and communication lines it is expedient to use the principle of optimal distribution of measurement and control functions between elements of the measuring complex. Based on this it was complemented the application of control devices schemes. In turn, the risk of fires and device damage from lightning discharge will be greatly reduced. The measures are recommended to be implemented in the operation and electronic devices maintenance fields.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Ageyev D, Al-Ansari A (2015) LTE RAN and services multi-period planning. In: 2015 second international scientific-practical conference problems of infocommunications science and technology (PIC S&T). IEEE, Kharkov, Ukraine, pp 272–274. https://doi.org/10.1109/infocommst.2015.7357334
Kisielewicz T, Battista Lo Piparo G, Mazzetti C (2016) Probability of surge protective device systems to reduce the risk of failure of apparatus due direct flashes to overhead low voltage lines. In: Proceedings of the 33th international conference on lightning protection (ICLP), Estoril, Portugal
Rudyk Y, Solonyi S (2010) The analyse of protecting schemes of electrical devices from impulsive overvoltage caused by thunderstorms and commutations. Fire Saf 17:20–25. https://journal.ldubgd.edu.ua/index.php/PB/article/view/959
Loshakov V, Moskalets M, Ageyev D, Drif A, Sielivanov K (2021) Adaptive space-time and polarisation-time signal processing in mobile communication systems of next generations. In: Radivilova T, Ageyev D, Kryvinska N (eds) Data-centric business and applications. lecture notes on data engineering and communications technologies, vol 48. Springer, Cham. https://doi.org/10.1007/978-3-030-43070-2_21
DSTU EN 62305-1:2012 Blyskavkozakhyst—Part 1: general principles [Effective from 2012-07-01]. K. Derzhstandart of Ukraine, 2012 (National Standard of Ukraine)
DSTU IEC 62305-2:2012 Blyskavkozakhyst—Part 2: Risk management [Effective from 2012-07-01]. K. Derzhstandart of Ukraine, 2012 (National Standard of Ukraine)
DSTU EN 62305-4:2012 Blyskavkozakhyst—Part 4: Electrical and electronic systems within structures [Effective from 2012-07-01]. K. Derzhstandart of Ukraine, 2012 (National Standard of Ukraine)
Maier V, Pavel SG, Beleiu HG, Fărcaş V (2016) Additional indicators for short time overvoltages and voltage impulses. In: 2016 international conference and exposition on electrical and power engineering (EPE), Iasi, pp 827–831. https://doi.org/10.1109/ICEPE.2016.7781452
Kryvinska N, Zinterhof P, van Thanh D (2007) New-emerging service-support model for converged multi-service network and its practical validation. In: First internationalconference on complex, intelligent and software intensive systems (CISIS’07). IEEE, pp 100–110. https://doi.org/10.1109/cisis.2007.40
Ageyev D et al (2018) Method of self-similar load balancing in network intrusion detection system. In: 2018 28th international conference radioelektronika (RADIOELEKTRONIKA). IEEE, pp 1–4. https://doi.org/10.1109/radioelek.2018.8376406
Shishlakov V, Vataeva E, Reshetnikova N, Shishlakov D, Solenaya O (2020) Synthesis of nonlinear impulse systems at “Proceedings of 14th international conference on electromechanics and robotics “Zavalishin’s Readings”“. Springer Science and Business Media LLC, pp 469–476
Lin H, Wang C, Lei W (2016) The design of overvoltage testing system for communication equipment in smart grid. In: 2016 IEEE PES Asia-Pacific power and energy engineering conference (APPEEC), Xi’an, pp 1812–1816. https://doi.org/10.1109/appeec.2016.7779802
Lennerhag O, Lundquist J, Engelbrecht C, Karmokar T, Bollen M (2019) An improved statistical method for calculating lightning overvoltages in HVDC over-head line/cable systems. Energies 12(16):3121
Kryvinska N, Zinterhof P, van Thanh D (2007) An analytical approach to the efficient real-time events/services handling in converged network environment. In: Enokido T, Barolli L, Takizawa M (eds) Network-based information systems. NBiS 2007. Lecture notes in computer science, vol 4658. Springer, Berlin, Heidelberg
Stanković KD, Perazić LS (2019) Determination of gas-filled surge arresters life-time. IEEE Trans Plasma Sci 47(1):935–943. https://doi.org/10.1109/TPS.2018.2874938
Kryvinska N, Zinterhof P, van Thanh D (2007) New-emerging service-support model for converged multi-service network and its practical validation. In: First international conference on complex, intelligent and software intensive systems (CISIS’07). IEEE, pp 100–110. https://doi.org/10.1109/cisis.2007.40
Rudyk Y, Shunkin V (2019) Compliance with lightning location systems indicators for risk assessment, loss prevention, investigation of causes. Fire Saf 35:54–62. https://doi.org/10.32447/20786662.35.2019.09
Barabash O, Shevchenko G, Dakhno N, Neshcheret O, Musienko A (2017) Information technology of targeting: optimization of decision making process in a competitive environment. Int J Intell Syst Appl 9(12):1–9. https://doi.org/10.5815/ijisa.2017.12.01
Vanko VM (2005) Sposib vyyavlennya ta vymiryuvannya parametriv yakosti impul’snoyi napruhy elektrychnoyi merezhi. [A method for detecting and measuring the quality parameters of the pulse voltage of the electric network]. Vidbir ta obrobka informatsiyi, (23), pp 69–74 (In Ukrainian)
Vanko VM (2005) Patent of Ukraine №72638. Tsyfrovyy vol’tmetr zminnoyi napruhy elektromerezhi [Digital active currence network voltmeter] Bulletin of inventions (3) (In Ukrainian)
Hudym V, Yurkiv B, Nazarovets O (2018) Mathematical modeling of heating processes in conductors of internal electrical networks in housing and public buildings. Fire Saf 26:59–64. Retrieved from https://journal.ldubgd.edu.ua/index.php/PB/article/view/273
Soloniy SV, Kovalev OP, Belousenko IV, Ershov MS, Demchenko GV, Vasin OO Pat. of the Useful model 59344 Ukraine, IPC (2011.01) N02H 3/16. Device protection against sparking in electrical networks of objects related to human life. Owner Donetsk National Technical University. № u201012991; declared 01.11.10; publ. 10.05.11, Bull. № 9 (In Ukrainian)
Solyonyj S, Rudyk Y, Demchenko G, Bennis Usef A (2011) The analysis of signals for prevention of a low-voltage electric network isolation ignition. Fire Saf 19:149–155. Retrieved from https://journal.ldubgd.edu.ua/index.php/PB/article/view/951
Wang S et al (2018) Analysis of lightning-induced overvoltage waveform parameters. In: 2018 34th international conference on lightning protection (ICLP), Rzeszow, pp 1–5. https://doi.org/10.1109/iclp.2018.8503345
Lappe R, Fisher F (1986) Izmerenia v energeticheskoy electronice [Measurements in power electronics]. Moskow (In Russian)
Nosov VV (1987) Promyshlennye pomekhi i obespechenie nadezhnosti funktsionirovaniya sistem upravleniya tekhnologicheskim protsessami [Industrial interference and ensuring the reliability of the operation of process control systems]. Izmereniya, kontrol, avtomatizatsiya, (2), pp 61–71 (In Russian)
Barabash O, Lukova-Chuiko N, Sobchuk V, Musienko A (2018). Application of petri networks for support of functional stability of information systems. In: Proceedings of 2018 IEEE 1st international conference on system analysis and intelligent computing, SAIC 2018. IEEE, Kyiv, Ukraine, pp 1–4. https://doi.org/10.1109/SAIC.2018.8516747
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this chapter
Cite this chapter
Rudyk, Y., Kuts, V., Nazarovets, O., Zdeb, V. (2021). Complex Tools for Surge Process Analysis and Hardware Disturbance Protection. In: Ageyev, D., Radivilova, T., Kryvinska, N. (eds) Data-Centric Business and Applications. Lecture Notes on Data Engineering and Communications Technologies, vol 69. Springer, Cham. https://doi.org/10.1007/978-3-030-71892-3_9
Download citation
DOI: https://doi.org/10.1007/978-3-030-71892-3_9
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-71891-6
Online ISBN: 978-3-030-71892-3
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)