This paper analyses the production of the current shunt and the influence factor. Then establish the tower overhead ground wire current shunt model. The current commonly used grounding resistance measurement method for shaking table method and clamp meter, shaking table method need to disconnect the ground lead line, the measuring error of clamp meter, based on the two methods proposed a new method of grounding measurement, continuous grounding the premise the high frequency power supply to achieve the measurement of grounding resistance. According to the model, this paper explained the relationship between the injecting current shunt coefficient and the overhead ground wire and voltage frequency when testing the grounding resistance. As a key to frequency characteristics of overhead ground wire, we offered a new method of measuring tower grounding resistance called high-frequency power method and got the best injection current frequency by tower split calculate. Compared with the shaking table method, the clamp table method is the most error, and the randomness of measured data is very strong. Followed by different frequency power measurement, the measuring result of the high-frequency power supply is close to that of the shake table method, and the error is less than 10%.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Liu, Z., Xu, J.: Comparison of several kinds of the instrument for measuring grounding resistance of tower. High Volt. Eng. 27(5), 76–77 (2001)
Ye, T.F.: Research and development for the measurement system of large grounding impedance based on the shunt function of overhead lightning conductor. North China Electri. Power Univ. Wuhan (2012)
Liu, W., Liu, Y., Liu, H.T.: Grounding resistance measurement error analysis for grounding device and overhead grounding line connection not disconnected. Insul. Surge Arresters 4(2), 62–65 (2012)
Dawalibi, F.: Ground fault current distribution between soil and neutral conductors. IEEE Trans on Power Apparatus and Systems 99(2), 452–461 (1980)
Niles, G.B.: Measurements and computations of fault current distribution on overhead transmission lines. IEEE Trans. Power Apparatus Syst. 103(3), 553–560 (1984)
Zou, J.F.: Computation of fault current distribution and shielding coefficients of ground wires for overhead transmission lines. Power Syst. Technol. 24(10), 27–30 (2000)
Zhao, B., Li, L., Cui, X.: Shunt currents computation of ground lines in power circuits. J. North China Electr. Power Univ. 29(4), 5–7 (2002)
Zhang, Q.: New technology of surveying the pole lapping earth resistance based on the high-frequency parallel method and its equipment. High Volt. Eng. 33(1), 194–195 (2007)
Li, D.J., Wang, W., Zhang, Y.: A new analysis approach on the coefficient of lightning shield line when the earth short circuit taking place in substation. Insul. Surge Arresters 8(1), 48–51 (2014)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Pei, Y. et al. (2020). Implementation of Tower Grounding Resistance Measurement Based on Decreasing Overhead Grounding Line’s Current Shunt Using High-Frequency Power Supply. In: Hassanien, A., Azar, A., Gaber, T., Bhatnagar, R., F. Tolba, M. (eds) The International Conference on Advanced Machine Learning Technologies and Applications (AMLTA2019). AMLTA 2019. Advances in Intelligent Systems and Computing, vol 921. Springer, Cham. https://doi.org/10.1007/978-3-030-14118-9_80
Download citation
DOI: https://doi.org/10.1007/978-3-030-14118-9_80
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-14117-2
Online ISBN: 978-3-030-14118-9
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)