Abstract
A new spectrofluorometric method for the determination of glutathione based on the reaction catalyzed by hemoglobin was reported. The reaction product gave a highly fluorescent intensity with the excitation and emission wavelengths of 320.0 nm and 413.0 nm, respectively. The optimum experimental conditions were investigated. Results showed that low concentration glutathione enhanced the fluorescence intensity significantly. The line ranges were 1.0 × 10–6–1.0 × 10–5 mol L–1 of glutathione and 6.0 × 10-10 mol L-1–1.0 × 10-8 mol L-1, respectively. The detection limit was calculated to be 1.1 × 10-11 mol L-1. The recovery test by the standard addition method gave values in the range of 90.78%-102.20%. This method was used for the determination of glutathione in synthetic and real samples with satisfactory results.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
A. Meiser and M. Anderson, Ann. Rev. Biochem. 52, 711 (1983).
R. Masella, R. D. Benedetto, R. Vari, C. Filesi, and C. Giovannini, J. Nutr. Biochem. 16, 577 (2005).
M. Penninckx, Enzyme Microb. Technol. 26, 737 (2000).
G. L. Ellman, Arch. Biochem. Biophys. 82, 70 (1959).
A. Tunek, K. L. Platt, and M. Przybylski, Chem. Biol. Interact. 33, 1 (1980).
C. H. Feng, H. Y. Huang, and C. Y. Lu, Anal. Chim. Acta 690, 209 (2011).
A. Bohmer, J. Jordan, and D. Tsikas, Anal. Biochem. 410, 296 (2011).
W. Buchberger and K. Winsauer, Anal. Chim. Acta 196, 251 (1987).
G. Y. Shi, J. X. Lu, and F. Xu, Anal. Chim. Acta 391, 307 (1999).
C. K. Zacharis, P. D. Tzanavaras, and A. Zotou, Anal. Chim. Acta 690, 122 (2011).
R. L. Norris, G. K. Eaglesham, and G. R. Shaw, J. Chromatogr. B 762, 17 (2001).
M. Fujita, M. Sano, K. Takeda, and I. Tomita, Analyst 118, 1289 (1993).
A. E. Katrusiak, P. G. Paterson, H. Kamencic, A. Shoker, and A. W. Lyon, J. Chromatogr. B 758, 207 (2001).
R. A. Winters, J. Zukowski, N. Ercal, R. H. Matthews, and D. R. Spitz, Anal. Biochem. 227, 14 (1995).
J. Chen, Z. Y. He, H. Liu, and C. S. Cha, J. Electr. Chem. 588, 324 (2006).
F. Ricci, F. Arduini, and C. S. Tuta, Anal. Chim. Acta 588, 164 (2006).
A. Salimi and S. Pourbeyram, Talanta 60, 205 (2003).
A. K. Sakhi, K. M. Russnes, S. Smeland, R. Blomhoff, and T. Gundersen, J. Chromatogr. A 1104, 179 (2006).
C. M. Percy, Y. C. T. Karin, F. H. Nelci, and T. K. Lauro, Clin. Chim. Acta 371, 152 (2006).
F. Tietze, Anal. Biochem. 27, 502 (1969).
A. R. T. S. Araujo, M. L. M. F. S. Saraiva, and J. L. F. C. Lima, Talanta 74, 1511 (2008).
O. W. Griffith, Anal. Biochem. 106, 207 (1980).
T. Toyo-oka, J. Tanabe, and Y. Kashihara, Anal. Chim. Acta 433, 1 (2001).
W. Wang, H. Xin, and H. G. Shao, J. Chromatogr. B 789, 425 (2003).
K. Mahesh and P. Rosaria, Anal. Biochem. 269, 410 (1999).
S. C. Liang, H. Wang, and Z. M. Zhang, Anal. Chim. Acta 451, 211 (2002).
K. J. Huang, Q. S. Jing, C. Y. Wei, and Y. Y. Wu, Spectrochim. Acta Part A 79, 1860 (2011).
S. Wang, H. Ma, J. Li, X. Chen, Z. Bao, and S. Sun, Talanta 70, 518 (2006).
S. Y. Lim, S. Lee, S. B. Park, and H. Kim, Tetrahedron Lett. 52, 3902 (2011).
P. W. Washko, R. W. Welch, and K. R. Dhariwa, Anal. Biochem. 204, 1 (1992).
D. J. Li and G. L. Zou, Wuhan Daxue Xuebao (Lixueban) 49, 765 (2003).
N. L. Tang, X. L. Meng, and Y. F. Ling, Huaxue Shijie 52, 216 (2011).
R. Wang, Z. Liu, R. Cai, and X. Li, Anal. Sci. 18, 977 (2002).
C. K. Zacharis and P. D. Tzanavaras, Comb. Chem. High Throughput Screening 13, 461 (2010).
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Wang, R., Tang, L., Li, H. et al. Hemoglobin-catalyzed fluorometric method for the determination of glutathione. Opt. Spectrosc. 120, 164–170 (2016). https://doi.org/10.1134/S0030400X15120218
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0030400X15120218