The goal of this investigation was to determine if the conductance catheter technique for chamber volume measurement could be applied in vivo to determine real-time phasic aortic segmental volume. A four-electrode conductance catheter was used to measure time-varying resistance of the descending thoracic aorta in open-chest, anesthetized dogs. Resistance was converted to segmental volume and the slope correction factor (α) and parallel conductance volume (V P ) were determined. The results showed excellent linear correlation between conductance and sonomicrometric segmental volume. The correction factors α and V P were found to be empirically related to average vessel diameter. The relatively high values for the slope correction factor (α=4.59±0.17 SEM) were found to be primarily related to low-resistivity shunt paths probably originating in the periadventitial aortic wall and to a lesser extent to changes in flow-induced increases in blood resistivity, hematocrit, catheter position, and other adjacent tissue resistivity. The results demonstrate that correction factors empirically derived from measurements of mean aortic diameter could be used to determine absolute real-time phasic segmental volume, cross-sectional area, or diameter. The conductance technique may possess the same potential for determining aortic mechanical properties which has already been demonstrated for determining ventricular mechanical properties.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
REFERENCES
Amirhamzeh, M. M. R., C.-X. Jia, and H. M. Spotnitz. Extrinsic factors influencing left ventricular conductance in situ. Circulation90:II-347-II-352, 1994.
Baan, J., T. T. Aouw, P. L. M. Kerkhof, R. J. Moene, A. D. Van Dijk, E. T. Van Der Velde, and J. Koops. Continuous stroke volume and cardiac output from intraventricular dimensions obtained with impedance catheter. Cardiovasc. Res.15:328-334, 1981.
Baan, J., E. T. Van Der Velde, H. G. De Bruin, G. J. Smeenk, J. Koops, A. D. Van Duk, D. Temmerman, J. Senden, and B. Buis. Continuous measurement of left ventricular volume in animals and humans by conductance catheter. Circulation70:812-823, 1984.
Ferguson III, J. J., M. J. Miller, P. Sahagian, J. M. Aroesty, and R. G. McKay. Assessment of aortic pressure-volume relationships with an impedance catheter. Cath. Cardiovasc. Diagn.15:27-36, 1988.
Frobert, O., J. H. Strorkholm, H. Gregersen, and J. P. Bagger. In vivoassessment of luminal cross-sectional areas and circumferential tension-strain relations of the porcine aorta. Scand. J. Thorac.30:12-19, 1996.
Gawne, T. J., K. S. Gray, and R. E. Goldstein. Estimating left ventricular offset volume using dual-frequency conductance catheters. J. Appl. Physiol.63(2):872-876, 1987.
Hettrick, D. A., J. H. Battocletti, J. A. Ackmann, J. H. Linehan, and D. C. Warltier. In vitroand finite-element model investigation of the conductance technique for measurement of aortic segmental volume. Adv. Biomed. Eng.24:675-684, 1996.
Hettrick, D. A., J. H. Battocletti, J. J. Ackmann, J. H. Linehan, and D. C. Warltier. Effects of physical parameters on the cylindrical model for volume measurement by conductance. Adv. Biomed. Eng.25:126-134, 1997.
Kanai, H., N. Nakayama, and N. Ono. Impedance of blood: The effects of the orientation of red blood cells. Digest of the 10th International Conference on Medical and Biological Engineering 2:34, 1973.
Peura, R. A., B. C. Penney, J. Arcuri, and F. A. Anderson, Jr. Influence of erythrocyte velocity on impedance plethysmographic measurements. Med. Biol. Eng. Comp.16:147-154, 1978.
Spinelli, J. C., and M. E. Valentinuzzi. Conductivity and geometrical factors affecting volume measurements with an impedancimetric catheter. Med. Biol. Eng. Comp.24:460- 464, 1986.
Stone, D. N., and J.-P. L. Dujardin. Changes in smooth muscle tone influence characteristic impedance of the aorta. Am. J. Physiol.246:H1-H7, 1984.
Szwarc, R. S., L. L. Mickleborough, S.-I. Mizuno, G. J. Wilson, P. Liu, and S. Mohamed. Conductance catheter measurements of left ventricular volume in the intact dog: Parallel conductance is independent of left ventricular size. Cardiovasc. Res.28:252-258, 1994.
Visser, K. R. Electric properties of flowing blood and impedance cardiography. Adv. Biomed. Eng.17:463-473, 1989.
Woodard, J. C., C. D. Bertram, and B. S. Gow. Effect of radial position on volume measurements using the conductance catheter. Med. Biol. Eng. Comput.27:25-32, 1989.
Young, Jr., D. G., R. H. Cox, E. K. Stoner, and W. J. Erdman. Evaluation of quantitative impedance plethysmography for continuous blood flow measurement. Am. J. Phys. Med.46:1373-1383, 1967.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hettrick, D.A., Battocletti, J., Ackmann, J. et al. In Vivo Measurement of Real-Time Aortic Segmental Volume Using the Conductance Catheter. Annals of Biomedical Engineering 26, 431–440 (1998). https://doi.org/10.1114/1.36
Issue Date:
DOI: https://doi.org/10.1114/1.36