Abstract
We examined the effect of oil retention on the heat transfer performance of a shell-and-tube-type evaporator which had 26 inner tubes and was filled with the refrigerant R-134a. The refrigerant was boiled on the surface of the inner tubes in the evaporator, while chilled water circulated through these tubes. An experimental apparatus was designed to measure both the pressure and temperature profiles at the inlet and outlet of the flooded evaporator. Four windows were installed for observing the operation of the flooded evaporator. A series of experiments were carried out under the following conditions: the refrigerant saturation temperature, 5 °C; refrigerant inlet quality, 0.1; heat fluxes from water to the refrigerant, 5–7 kW/m2. The concentration of the oil retained in the refrigerant was then varied up to approximately 10% to observe the effect on the heat transfer performance of the flooded evaporator. Increasing the oil content (i.e., increasing the concentration up to a maximum of approximately 10%) in the refrigerant R134a did not lead to any appreciable reduction in the overall heat transfer coefficient of a flooded evaporator with multiple-innertubes. When the oil concentration in the refrigerant was approximately 10%, the heat transfer degradation in the case of the flooded evaporator with multiple-inner-tubes was approximately 11%, which was found to be much smaller than the heat transfer degradation in the case of a flooded evaporator with a single-tube (26–49%). This observation suggested that the oil retained in the refrigerant did not significantly deteriorate the heat transfer performance of the flooded evaporator, presumably because the presence of tube bundles promoted forced convection by agitating bubbles.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
D.K. Mohanty and P.M. Singru, Korean J. Chem. Eng., 29(9), 1144 (2012).
B. H. Chun, H. U. Kang and S. H. Kim, Korean J. Chem. Eng., 25(5), 966 (2008).
R.L. Webb and W. F. McQuade, ASHRAE Trans., 99(1), 225 (1993).
J. C. Chen, ASME Paper 63-HT-34 (1963).
N. H. Kim and D.Y. Kim, Int. J. Heat Mass Transf., 2311 (2010).
R. L. Webb and W. F. McQuade, ASHRAE Trans., 99, 1225 (1993).
J. Zheng, M.-C. Chyu and Z. Ayub, Int. J. Refrig., 31, 564 (2008).
M.-C. Chyu, J. Zheng and Z. Ayub, Int. J. Refrig., 32, 1876 (2009).
S. J. Kline and F. A. McClintock, Mech. Eng., 75, 3 (1953).
J. C. Chen, I & EC Process Design and Development, 5(3), 322 (1966).
M.W. Browne and P. K. Bansal, Appl. Therm. Eng., 19, 595 (1999).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Koo, KM., Lee, S., Kim, SG. et al. Heat transfer property of refrigerant-oil mixture in a flooded evaporator: The role of bubble formation and oil retention. Korean J. Chem. Eng. 30, 1029–1033 (2013). https://doi.org/10.1007/s11814-013-0024-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11814-013-0024-9