Abstract
Effective utilization of renewable energy sources and efficient management of electric energy are essential for any developing countries like India. This can be envisioned through the implementation of concepts of smart grid (SG). One of the key requisites for SG implementation is that the grid should be completely observable. Renovation of conventional Indian power grid to a SG necessitates incorporation of the phasor measurement units (PMUs) in the present power grid measurement and monitoring system. Since the cost of PMU is high and any bus containing a PMU makes the neighboring connected buses observable, optimal placement of PMUs is very important for complete observability of the grid. This paper proposes optimal redundant geographical locations in the northern, eastern and north-eastern regions of Indian power grid for PMU placement. The PMUs installed in these geographical locations will make the grid completely observable and maintain the observability under the conditions of failure of some PMUs or branch outages. Integer linear programming has been used for finding the optimal PMU locations. The results proposed in this paper can be a stepping stone for revamping the Indian power grid to a SG ensuring complete observability during different contingency conditions.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Power Finance Corporation Ltd. Restructured Accelerated Power Development and Reforms Programme (R-APDRP) of Govt. of India. 2012-12-29, http://www.cseb.gov.in/cspdcl/rapdrp/SCADADMS/RFP%20for%20SIA_05-12-2012.pdf
Taylor T, Ohrn M. Network Management for smart grids. 2013-03, http://www05.abb.com/global/scot/scot271.nsf/veritydisplay/461c2ae39130ceafc125762d0047f01f/$file/45-49%203M901_ENG72dpi.pdf
PSGuard. Improved Power System Performance through Wide Area Monitoring, Protection and Control. 2013-03, http://www05.abb.com/global/scot/scot221.nsf/veritydisplay/d271149a1ebc45f9c1256db900564198/$file/741_psg_e_04_v.5.pdf
Sinha A, Neogi S, Lahiri R N, Chowdhury S, Chowdhury S P, Chakraborty N. Smart grid initiative for power distribution utility in India. In: IEEE Power and Energy Society General Meeting. San Diego, USA, 2011, 1–8
Anderson P M, LeReverend B K. Industry experience with special protection schemes. IEEE Transactions on Power Systems, 1996, 11(3): 1166–1179
Phadke A G, Thorp J S, Adamiak M G. A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of frequency. IEEE Transactions on Power Apparatus and Systems, 1983, PAS-102(5): 1025–1038
Nuqui R F, Phadke A G. Phasor measurement unit placement techniques for complete and incomplete observability. IEEE Transactions on Power Delivery, 2005, 20(4): 2381–2388
Gou B. Generalized integer linear programming formulation for optimal PMU placement. IEEE Transactions on Power Systems, 2008, 23(3): 1099–1104
Abur A, Magnago F H. Optimal meter placement for maintaining observability during single branch outages. IEEE Transactions on Power Systems, 1999, 14(4): 1273–1278
Phadke A G, Thorp J S, Karimi K J. Real time voltage phasor measurements for static state estimation. IEEE Transactions on Power Apparatus and Systems, 1985, 104(11): 3098–3106
Garrity T F. Getting smart: innovations and trends for the future electric power systems. Power Systems Conference 2009 (PSC’09). Clemson, USA, 2008, 1–8
Flynn B. What is the real potential of the smart grid? The AMRA International Symposium. Reno, USA, 2007
Abbasy N H, Ismail H M. A unified approach for the optimal PMU location for power system state estimation. IEEE Transactions on Power Systems, 2009, 24(2): 806–813
Phadke A G, Thorp J S, Nuqui R F, Zhou M. Recent developments in state estimation with phasor measurements. Power Systems Conference and Exposition 2009 (PSCE’09). Seattle, USA, 2009, 1–7
Xu B, Abur A. Optimal placement of phasor measurement units for state estimation. Final Project Report, PSERC Publication 05-58, 2005
Mohammadi-Ivatloo B. Optimal placement of PMUs for power system observability using topology based formulated algorithms. Journal of Applied Sciences, 2009, 9(13): 2463–2468
Ghosh D, Ghose T, Mohanta D K. Communication feasibility analysis for smart grid with phasor measurement units. IEEE Transactions on Industrial Informatics, 2013, 99: 1–10
Gopakumar P, Chandra G S, Reddy M J B. Optimal placement of phasor measurement units for Tamil Nadu state of Indian power grid. In: Proceedings of 11th IEEE International Conference on Environment and Electrical Engineering (EEEIC). Venice, Italy, 2012, 80–83
Gopakumar P, Chandra G S, Reddy M J B, Mohanta D K. Optimal placement of PMUs for the smart grid implementation in Indian power grid — A case study. Frontiers in Energy, 2013, 7(3): 358–372
Schulze M A. Linear Programming for Optimization. 1998, http://www.markschulze.net/LinearProgramming.pdf
Power Grid Corporation Ltd. Govt. of India. Company Overview. 2013-03, www.powergridindia.com
Pradeep Y, Khaparde S A. Complex event processing of high level events in multi-area power grid: An Indian perspective. In: IEEE Power and Energy Society Energy Meeting 2010. Minneapolis, MN, 2010, 1–6
Roy A, Khaparde S A, Pentayya P, Usha S, Abhayankar A R. Operating experience of regional interconnections in India. In: IEEE Power Engineering Society General Meeting, 2005, 2528–2535
Zhu F, Zheng Y, Guo X, Wang S. Environmental impacts and benefits of regional power grid inter connections for China. Energy Policy, 2005, 33(14): 1797–1805