Abstract
To achieve efficient control of supersonic compressor cascade flow, a type of spanwise distributed pulsed arc discharge plasma actuation (PADPA) was designed. To simulate the influences of PADPA on the flow field, a phenomenological model was established. Then, the flow control effects of PADPA on supersonic compressor cascade flow were researched numerically. The results show that under low static pressure ratio condition, the compressive wave induced by PADPA reduced the intensity of the passage shock wave, which eventually reduced shock wave loss. It was also found that PADPA produced an adverse pressure gradient (pre-compression effect) around the actuation location, which reduced the strength of the high adverse pressure gradient induced by the passage shock wave. The airflow on both sides of the actuation location was accelerated by PADPA owing to the spanwise distributed layout. Thus, it improved the ability of the boundary layer to resist the effect of the adverse pressure gradient and reduced the separation zone. Consequently, the total pressure loss was reduced by 6.8%. Under high pressure ratio condition, the effect of PADPA on the suction side controlling the large separation of the boundary layer was insignificant. The total pressure loss also increased slightly.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Holger B., Shock wave boundary layer interactions. Cambridge University Press, New York, USA, 2011.
Dolling D.S., Fifty years of shock-wave/boundary-layer interaction research: what next? AIAA Journal, 2001, 39(8): 1517–1531.
Panaras A.G., Lu F.K., Micro-vortex generators for shock wave/boundary layer interactions. Progress in Aerospace Sciences, 2015, 74: 16–47.
John A., Qin N., Shahpar S., Using shock control bumps to improve transonic fan/compressor blade performance. Journal of Turbomachinery, 2019, 141(8): 081003.
Yu S., Schnerr G.H., Dohrmann U., Passive control of shock-boundary layer interaction in transonic axial compressor cascade flow. Fluid- and Gasdynamics, 1994, 4: 207–217.
Szwaba R., Comparison of the influence of different air-jet vortex generators on the separation region. Aerospace Science & Technology, 2011, 15(1): 45–52.
Hergt A.S., Klinner J., Grund S., On the importance of transition control at transonic compressor blades. ASME Turbo Expo 2019, Phoenix, USA, GT2019-90440.
Mao X., Liu B., Zhang G., Control of separations in a highly-loaded axial compressor cascade by tailored boundary layer suction. ASME Turbo Expo 2015, Montreal, Canada, GT2016-56795.
Wu Y., Li Y.H., Progress and outlook of plasma flow control. Acta Aeronautica et Astronautica Sinica, 2015, 36(02): 381–405.
Li Y.H., Wu Y., Zhou M., Control of the corner separation in a compressor cascade by steady and unsteady plasma aerodynamic actuation. Experiments in Fluids, 2010, 48(6): 1015–1023.
Akcayoz E., Duc V.H., Mahallati A., Controlling corner stall separation with plasma actuators in a compressor cascade. Journal of Turbomachinery, 2016, 138(8): 081008.
Zhang H.D., Wu Y., Yu X.J., Experimental investigation on the plasma flow control of axial compressor rotating stall. ASME Turbo Expo 2019, Phoenix, USA, GT2019-90609.
Li G., Xu Y.J., Yang L.Y., Low speed axial compressor stall margin improvement by unsteady plasma actuation. Journal of Thermal Science, 2014, 23(2): 114–119.
Zhang H.D., Wu Y., Li Y.H., Control of compressor tip leakage flow using plasma actuation. Aerospace Science and Technology, 2019, 86: 244–255.
Zhang H.D., Wu Y., Li Y.H., Mechanism of compressor airfoil boundary layer flow control using nanosecond plasma actuation. International Journal of Heat and Fluid Flow, 2019, 80: 108502.
Neumann P., De Almeida V.B., Motta V., Dynamic mode decomposition analysis of plasma aeroelastic control of airfoils in cascade. Journal of Fluids and Structures, 2020, 94: 102901.
Gan T., Wu Y., Sun Z.Z., Shock wave boundary layer interaction controlled by surface arc plasma actuators. Physics of Fluids, 2018, 30(5): 055107.
Schulein E., Zheltovodov A.A., Effects of steady flow heating by arc discharge upstream of non-slender bodies. Shock Waves, 2011, 21(4): 383–396.
Firsov A.A., Savelkin K., Yarantsev D., Plasma-enhanced mixing and flameholding in supersonic flow. Philosophical Transactions of the Royal Society A, 2015, 373(2048): 20140337.
Jin D., Cui W., Li Y., Li F., Jia M., Sun Q., Characteristics of pulsed plasma synthetic jet and its control effect on supersonic flow. Chinese Journal of Aeronautics, 2015, 28(1): 66–76.
Sun Q., Li Y., Cheng B., The characteristics of surface arc plasma and its control effect on supersonic flow. Physics Letters A, 2014, 378(36): 2672–2682.
Zhao G.Y., Li Y.H., Liang H., Phenomenological modeling of nanosecond pulsed surface dielectric barrier discharge plasma actuation for flow control. Acta Physica Sinica, 2015, 64(1): 166–176.
Gan T., Jin D., Guo S., Influence of ambient pressure on the performance of an arc discharge plasma actuator. Contributions to Plasma Physics, 2018, 58(4): 260–268.
Tweedt D.L., Schreiber H.A., Starken H., Experimental investigation of the performance of a supersonic compressor cascade. Journal of Turbomachinery, 1988, 110(4): 456–466.
Acknowledgments
This research is supported by National Natural Science Foundation of China (Grant No. 51790511, 51906254).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sheng, J., Wu, Y., Zhang, H. et al. Flow Control Effect of Spanwise Distributed Pulsed Arc Discharge Plasma Actuation on Supersonic Compressor Cascade Flow. J. Therm. Sci. 31, 1723–1733 (2022). https://doi.org/10.1007/s11630-020-1382-3
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11630-020-1382-3