Abstract
To develop a quantitative understanding of unsteady and interacting turbomachine flow fields, it is necessary to quantify the instantaneous efficiency of high speed turbomachines. This requires the measurement of both the unsteady velocity and total temperature variation in the exit flow of a high speed rotor. In this paper, techniques to utilize a single slant-film anemometer to measure unsteady total temperature are developed and evaluated. Then a series of preliminary experiments are performed in a high speed axial fan facility to quantify the instantaneous rotor efficiency. This is accomplished by utilizing these single slant-film methods to measure the total temperature in the rotor wakes. Results show that measurements at multiple overheats and several probe orientations are required. The simplest method proves to be useful for determining parameters used in other methods. An analysis based on King’s law gives good results even when measurements are outside the calibration range. Within the calibration range, a polynomial representation of the wire response to mass flux and total temperature yields good total temperature fluctuation results. A model analysis technique is also assessed.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Author information
Authors and Affiliations
Additional information
Received: 13 November 1997/Accepted: 16 February 1998
Rights and permissions
About this article
Cite this article
Johnston, R., Fleeter, S. High speed rotor wake total temperature measurements using a hot-film anemometer. Experiments in Fluids 25, 337–346 (1998). https://doi.org/10.1007/s003480050238