Abstract
Recently it has been shown both theoretically and experimentally that, for certain operating conditions of a caesium fountain primary frequency standard, the cold-collision frequency shift, which can be a limit to the accuracy of the standard, strongly varies with the clock state composition and can be cancelled. This offers the intriguing prospect of operating a fountain standard at the zero-shift point, where no correction for collisions needs to be applied. We estimate expected improvements in the standard’s accuracy and a potential shortening of the averaging time. Lastly, we derive relevant requirements for the key experimental parameters.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
R. Wynands, S. Weyers, Metrologia 42, S64 (2005)
P. Leo, P.S. Julienne, F.H. Mies, C.J. Williams, Phys. Rev. Lett. 86, 3743 (2001)
F. Levi, D. Calonico, L. Lorini, A. Godone, Metrologia 43, 545 (2006)
T.P. Heavner, S.R. Jefferts, E.A. Donley, J.H. Shirley, T.E. Parker, Metrologia 42, 411 (2005)
K. Gibble, S. Chu, Phys. Rev. Lett. 70, 1771 (1993)
S. Weyers, A. Bauch, R. Schroeder, C. Tamm, Proc. 6th Symp. on Frequency Standards and Metrology, ed. by P. Gill (World Scientific, Singapore, 2002), p. 64
F. Pereira Dos Santos, H. Marion, S. Bize, Y. Sortais, A. Clairon, C. Salomon, Phys. Rev. Lett. 89, 233004 (2002)
K. Gibble, B.J. Verhaar, Phys. Rev. A 52, 3370 (1995)
K. Szymaniec, W. Chalupczak, E. Tiesinga, C.J. Williams, S. Weyers, R. Wynands, Phys. Rev. Lett. 98, 153002 (2007)
C. Chin, V. Vuletic, A.J. Kerman, S. Chu, E. Tiesinga, P.J. Leo, C.J. Williams, Phys. Rev. A 70, 032701 (2004)
W. Chalupczak, K. Szymaniec, J. Phys. B 40, 343 (2007)
K. Gibble, S. Chang, R. Legere, Phys. Rev. Lett. 75, 2666 (1995)
V. Venturi, E. Tiesinga, C.J. Williams, (unpublished)
G. Santarelli, P. Laurent, P. Lemonde, A. Clairon, A.G. Mann, S. Chang, A.N. Luiten, C. Salomon, Phys. Rev. Lett. 82, 4619 (1999)
K. Gibble, private communication
C.G. Townsend, N.H. Edwards, C.J. Cooper, K.P. Zetie, C.J. Foot, A.M. Steane, P. Szriftgiser, H. Perrin, J. Dalibard, Phys. Rev. A 52, 1423 (1995)
G. Santarelli, C. Audoin, A. Makdissi, P. Laurent, G.J. Dick, A. Clairon, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 45, 887 (1998)
P. Laurent, M. Abgrall, C. Jentsch, P. Lemonde, G. Santarelli, A. Clairon, I. Maksimovic, S. Bize, C. Salomon, D. Blonde, J.F. Vega, O. Grosjean, F. Picard, M. Saccoccio, M. Chaubet, N. Ladiette, L. Guillet, I. Zenone, C. Delaroche, C. Sirmain, Appl. Phys. B 84, 683 (2004)
K. Szymaniec, W. Chalupczak, P.B. Whibberley, S.N. Lea, D. Henderson, Metrologia 42, 49 (2005)
C. Fertig, K. Gibble, Phys. Rev. Lett. 85, 1622 (2000)
S. Bize, Y. Sortais, C. Mandache, A. Clairon, C. Salomon, IEEE Trans. Instrum. Meas. 50, 503 (2001)
J. Vanier, C. Audoin, The Quantum Physics of Atomic Frequency Standards (Adam Hilger, Bristol, Philadelphia, 1989), p. 830
H. Marion, S. Bize, L. Cacciapuoti, D. Chambon, F. Pereira dos Santos, G. Santarelli, P. Wolf, A. Clairon, Proc. 18th European Frequency and Time Forum (2004)
F. Levi, A. Godone, L. Lorini, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 48, 847 (2001)
K. Szymaniec, W. Chalupczak, S. Weyers, R. Wynands, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 54, 1721 (2007)
R. Li, K. Gibble, Metrologia 41, 376 (2004)
S.R. Jefferts, J.H. Shirley, N. Ashby, E.A. Burt, G.J. Dick, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 2314 (2005)
S. Weyers, R. Schroeder, R. Wynands, Proc. 20th European Frequency and Time Forum (2006), p. 173
Author information
Authors and Affiliations
Corresponding author
Additional information
PACS
32.80.Pj; 06.20.-f
Rights and permissions
About this article
Cite this article
Szymaniec, K., Chalupczak, W., Weyers, S. et al. Prospects of operating a caesium fountain clock at zero collisional frequency shift. Appl. Phys. B 89, 187–193 (2007). https://doi.org/10.1007/s00340-007-2813-5
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00340-007-2813-5