We have employed a CO2-laser/microwave-sideband spectrometer to carry out saturation-dip sub-Doppler measurements of a number of 2ν2 overtone transitions of OCS in the 10-μm region. The OCS frequencies have been obtained with an absolute accuracy of order ±37 kHz, as determined from a careful analysis of the combined uncertainties in the frequency of our Lamb-dip-locked laser and the centers of the observed OCS saturation signals. Our ±37 kHz measurement accuracy is consistent with literature OCS sub-Doppler data obtained on a similar instrument. The results serve to extend the comb of precise reference frequencies in the 10-μm region and to determine the magnitudes of systematic and random uncertainties of our CO2 laser.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Z.-D. Sun, Q. Liu, R.M. Lees, L.-H. Xu, M.Yu. Tretyakov, V.V. Dorovskikh: “Dual-ModeCO2-Laser/Microwave-Sideband Spectrometer with Broadband and Saturation Dip Detection for CH3OH”, submitted to Rev. Sci. Instrum., in print
Z.-D. Sun, R.M. Lees, L.-H. Xu, M.Yu. Tretyakov, I. Yakovlev: Int. J. Infrared Millimeter Waves 23, 1557 (2002)
K.M. Evenson, C.-C. Chou, B.W. Bach, K.G. Bach: IEEE J. Quantum Electron. 30, 1187 (1994)
P.K. Cheo: IEEE J. Quantum Electron. QE-20, 700 (1984)
H. Fichoux, E. Rusinek, M. Khelkhal, J. Legrand, F. Herlemont, A. Fayt: J. Mol. Spectrosc. 189, 249 (1998)
A.G. Maki, J.S. Wells: Wavenumber Calibration Tables from Heterodyne Frequency Measurements (National Institute of Standards and Technology Special Publication 821, U.S. Department of Commerce, Washington, DC 1991) and references therein
C. Freed, A. Javan: Appl. Phys. Lett. 17, 53 (1970)
G. Duxbury: private communication
A.G. Maki, C.-C. Chou, K.M. Evenson, L.R. Zink, J.-T. Shy: J. Mol. Spectrosc. 167, 211 (1994)
H. Odashima, M. Tachikawa, L.R. Zink, K.M. Evenson: J. Mol. Spectrosc. 188, 245 (1998)
G. Moruzzi, B.P. Winnewisser, M. Winnewisser, I. Mukhopadhyay, F. Strumia: Microwave, Infrared and Laser Transitions of Methanol (CRC Press, Boca Raton, FL 1995)
T.D. Varberg, K.M. Evenson: IEEE Trans. Instrum. Meas. 42, 412 (1993)
H. Odashima, F. Matsushima, K. Nagai, S. Tsunekawa, K. Takagi: J. Mol. Spectrosc. 173, 404 (1995)
L.-H. Xu, J.T. Hougen: J. Mol. Spectrosc. 173, 540 (1995)
Author information
Authors and Affiliations
Corresponding author
Additional information
PACS
07.57.Ty; 33.20.Ea; 42.62.Fi
Rights and permissions
About this article
Cite this article
Sun, ZD., Liu, Q., Lees, R. et al. Saturation-dip measurements in the 2ν2 overtone band of OCS with a CO2-laser/microwave-sideband spectrometer. Appl. Phys. B 78, 791–795 (2004). https://doi.org/10.1007/s00340-004-1472-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00340-004-1472-z