Abstract.
The purpose of the study was the evaluation of low-dose spiral CT in the detection and assessment of contours of pulmonary nodules. In a prospective investigation 71 consecutive chest CT examinations were acquired both at 30 and 200 mA. Films were interpreted independently by two radiologists. According to the size, nodules were divided into four categories: ≤ 3, 4–5, 6–10, and > 10 mm; nodule shape was registered. With both protocols, 240 nodules were detected. The correlation coefficient for both methods was 0.89. Discrepancies were found most frequently in nodules near to pulmonary vessels. Nodule size estimation did not differ more than one size category. Eight spiculated nodules were identified by both techniques. Low-dose spiral CT of the chest has a high sensitivity in the detection of pulmonary nodules. If clinical circumstances require dose minimization, low-dose spiral CT may be advocated as an alternative screening method to conventional dose spiral CT.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Author information
Authors and Affiliations
Additional information
Received 13 March 1997; Revision received 19 September 1997; Accepted 20 November 1997
Rights and permissions
About this article
Cite this article
Gartenschläger, M., Schweden, F., Gast, K. et al. Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT. Eur Radiol 8, 609–614 (1998). https://doi.org/10.1007/s003300050445