Abstract
A fluorescence intensity ratio technique has been applied to Pr3+: ZBLAN glass, realising a point temperature sensor. We present data for a blue light emitting diode-pumped prototype which provides accurate and self-referenced measurements.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
H. Berthou and C.K. Jorgensen: Opt. Lett.15 (1990) 1100.
E. Maurice, G. Monnom, B. Dussardier, A. Saïssy, D.B. Ostrowsky and G.W. Baxter: Opt. Lett.19 (1994) 990.
E. Maurice, G. Monnom, D.B. Ostrowsky and G.W. Baxter: Proc. SPIE2360 (1994) 219.
E. Maurice, G. Monnom, D.B. Ostrowsky and G.W. Baxter: J. Lightwave Technol.7 (1995) 1349.
E. Maurice, G. Monnom, D.B. Ostrowsky and G.W. Baxter: Appl. Opt.34 (1995) 4196.
E. Maurice, G. Monnom, B. Dussardier, A. Saïssy, D.B. Ostrowsky and G.W. Baxter: Appl. Opt.34 (1995) 8019.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Maurice, E., Monnom, G., Baxter, G.W. et al. Blue light-emitting-diode-pumped point temperature sensor based on a fluorescence intensity ratio in Pr3+: ZBLAN glass. Optical Review 4, A89–A91 (1997). https://doi.org/10.1007/BF02936000
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02936000