Abstract
Neutron activation analysis with a SLOWPOKE reactor relies on the stability of the neutron flux in the irradiation sites. Flux monitors were irradiated to measure the flux variation with the reactor temperature and with the amount of moderator in the irradiation vial. The thermal flux decreased by 2.7% for a 10‡C increase in reactor temperature. The thermal flux increased by up to 8% and the fast flux decreased by up to 13% depending on sample size and hydrogen content.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
D. E. Ryan, D. C. Stuart, and A. Chattopadhyay, Rapid multielement neutron activation analysis with a SLOWPOKE reactor,Anal. Chim. Acta 100, 87–93 (1978).
C. Bergerioux, G. Kennedy, and L. Zikovsky, Use of the semi-absolute method in neutron activation analysis,J. Radioanal. Chem. 50, 229–234 (1979).
G. Kennedy and J. St-Pierre, NAA with the improved relative method and the interactive computer program EPAA,J. Radioanal. Nucl. Chem. 169, 471–481 (1993).
F. De Corte, Thek0 standardization method: a move to the optimization of reactor neutron activation analysis, Habil. Thesis, University of Gent (1987).
O. Diaz Rizo, M. V. Manso Guevara, E. Herrera Peraza, I. Alvarez Pellon, and M. C. Lopez Reyes, Epithermal neutron flux characterization of the Triga Mark III reactor, Salazar, Mexico, for use in INAA,J. Radioanal. Nucl. Chem. 221, 95–97 (1997).
D. Thompson, S. Parry, and R. Benzing, Evaluation of nuclear effects in the analysis of plastics by neutron activation analysis,J. Radioanal. Nucl. Chem. 187, 255–263 (1994).
M. B. Alamin and N. M. Spyrou, Effects of hydration on elemental sensitivities in neutron activation analysis using prompt and delayed gamma rays,J. Radioanal. Nucl. Chem. 192, 39–14 (1995).
R. Matsushita, M. Koyama, S. Yamada, M. Kobayashi, and H. Moriyama, Neutron flux gradients and spectrum changes in the irradiation capsule for reactor neutron activation analysis,J. Radioanal. Nucl. Chem. 216, 95–99 (1997).