The 200 MWe Tonghae thermal power plant CFB boiler (2-units) is the largest boiler to fire a Korean anthracite coal for generation of electric power. The #1 unit CFB has been operated commercially since October 1998, and the #2 unit CFB, which will begin commercial operation in October 1999, is currently under construction. However, there is little operational data of the large CFB combustor firing anthracite coal, so it is necessary to predict the performance of the CFB combustor with variation of the operation conditions. Therefore, in this study, the simulation of the Tonghae CFB has been carried out to predict the performance with various nominal rates, coal particle size distribution and operating conditions. The simulation results with various loads could be fitted well to the design values at the given operation conditions. At the various operation conditions, the simulation results could explain the performance of the Tonghae CFBC well.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
ABB-CE, “General Design Conditions,” A Contract of Tonghae CFB Boiler,2,171 (1994).
Grace, J. R., Avidan, A. A. and Knowlton, T. M., “Circulating Fluidized Beds,” Blackie Academic & Professional London (1997).
Choi, J. H, Park, J. H, Choung, W. M, Kang, Y. and Kim, S. D., “Hydrodynamic Characteristics of Fine Particles in the Riser and Standpipe of a Circulating Fluidized Bed,”Korean J. Chem. Eng.,12,141 (1995).
Hannes, J. P., “Mathematical Modeling of CFBC: An Overview Modular Programming Frame Using a 1.5-Dimensional Riser Model,” Proc. of the 12th Int. Conf. on Fluidized Bed Combustion, 455 (1993).
Hannes, J. P., “Mathematical Modeling of Circulating Fluidized Bed Combustion,” PhD. Thesis, RWTH Aachen, Germany (1996).
Hannes, J. P., Renz, U. and Bleek, C. M., “The IEA Model for Circulating Fluidized Bed Combustion,” Proc. of the 13th Int. Conf. on Fluidized Bed Combustion, 287 (1995).
Korbee, R., “Regenerative Desulfurization in an Interconnected Fluidized Bed System,” Ph. D. Thesis, Delft, The Netherlands (1995).
Maitland, J. and Schaker, Y, “Design of the 200 MWe Tonghae Power Plant Circulating Fluidized Bed Steam Generator,” Proc. of the 14th Int. Conf. on Fluidized Bed Combustion, 191 (1997).
Shun, D, Bae, D. H, Hee, K, Son, J. E, Kang, Y, Wee, Y. H, Lee, J. S. and Ji, P. S., “Circulating Fluidized Bed Combustion of Korean Anthracite,”HWAHAK KONGHAK,34, 321 (1996).
Wen, Y. C. and Chen, L. H., “Fluidized Bed Phenomena: Elutriation and Entrainment,”AIChE Journal,6,117 (1982).
Wirth, K. E., “Axial Pressure Profile in Circulating Fluidized Beds,”Chem. Eng. Technol.,11,11 (1988).
Wirth, K. E., “Heat Transfer in Circulating Fluidized Beds,”Chem. Eng. Sci.,50, 2137 (1995).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lee, JM., Kim, JS. Simulation of the 200 MWe tonghae thermal power plant circulating fluidized bed combustor by using IEA-CFBC model. Korean J. Chem. Eng. 16, 640–645 (1999). https://doi.org/10.1007/BF02708145
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02708145