Abstract
A computational study on UV disinfection efficiency has been developed based on the Lambert-Beer law. Comparing a UV lamp arranged vertically to the flow of one arranged on an incline led to the conclusion that UV doses could be increased. The study of the inclination effect was divided into four stages in order to evaluate the increase in the UV dose at each stage. The slope of the inclined UV lamp ranged between 1‡ and 89‡ (0‡<θ<90‡) with other parameters such as diameter of the UV lamp, distance from the surface of the UV lamp, and velocity also recorded. The increase of UV dosage was largely affected by the diameter and velocity of the UV lamp, especially on a lesser slope. To obtain a greater UV dose, it was necessary to assemble UV lamps with lesser slopes. By arranging lamps on an incline, UV disinfection could be enhanced.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Alam, M. Z. B., Otaki, M., Furumai, H. and Ohgaki, S., “Direct and indirect inactivation of Microcystis Aeruginosa by UV-radiation,”Water Res.,35(4), 1008 (2001).
Andreadakis, A., Mamais, D., Christoulas, D. and Kabylafka, S., “Ultraviolet disinfection of secondary and tertiary effluent in the mediterranean region,”Water Sci. Technol.,40(4–5), 253 (1999).
Blatchley, E. R. III, Wood, W. L. and Schuerch, P., “UV pilot testing: intensity distribution and hydrodynamics,”J. Environ. Eng.,121(3), 258 (1995).
Campbell, A. T. and Wallis, P., “The effect of UV irradiation on humanderived Giardia Lambia cysts,”Water Res.,36(4), 963 (2002).
Craik, S. A., Weldon, D., Finch, G. R., Bolton, J.R. and Belosevic, M., “Inactivation of Cryptosporidium Parvum Oocysts using mediumand low-pressure ultraviolet radiation,”Water Res.,35(6), 1387 (2001).
Iranpour, R., Garnas, G., Moghaddam, O. and Taebi, A., “Hydraulic effects on ultraviolet disinfection: modification of reactor design,”Water Environ. Res.,71(1), 114 (1999).
Jolis, D. and Hirano, R.,Microfiltration and ultraviolet light disinfection for water reclamation, Bur Eng Dep Public Works., City and County of San Francisco (1993).
Loge, F. J., Emerick, R.W., Thompson, D. E., Nelson, D.C. and Darby, J. L., “Factors influencing ultraviolet disinfection performance part I: Light penetration to wastewater particles,”Water Environ. Res.,71(3), 377 (1999).
Moreno, B., Goni, F., Fernandez, O. and Martinez, J. A., “The disinfection of wastewater by ultraviolet light,”Water Sci. Technol.,35(11–12), 233 (1997).
Qualls, R.G., Flynn, M. P. and Johnson, J. D., “The role of suspended particles in ultraviolet disinfection,”J. Water Pol. Control Fed.,55, 1280 (1983).
Rajala-Mustonen, R. L., Toivola, P. S. and Heinonen-Tanski, H., “Effects of peracetic acid and UV irradiation on the inactivation of coliphages in wastewater,”Water Sci. Technol.,35(11–12), 237 (1997).
Scheible, O.K., “Development of a rationally based design protocol for the UV light disinfection process,”J. Water Pol. Control Fed.,59, 25 (1987).
USEPA,Ultraviolet disinfection technology assessment, EPA 832 R-92-004 (1992).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lim, SJ., Lee, YJ. Enhancement of UV disinfection efficiency by arraying inclined lamps. Korean J. Chem. Eng. 23, 595–600 (2006). https://doi.org/10.1007/BF02706800
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02706800