Abstract
The overall mass transfer coefficient kLa,F in the flow characteristics was determined by the measurement of the diffusivity of ozone, density of aqueous solution, and viscosity. However, the measured values kLa,F in the range of 0.0096–0.0622 min-1 show large changes in hydraulic retention time, and the dissolved ozone concentration CL,F presented under 0.1 mg/l is lower than the dissolved ozone observed. The overall mass transfer coefficient kLa,M in the ozone decomposition was determined by measurement of the equilibrium dissolved ozone, overall decomposition rate constant, and overall Henry’s law constant. The measured values kLa,M are in the range of 0.0441–0.0749 min-1, and they present small changes depending on the hydraulic retention time. Furthermore, the measured dissolved ozone concentration CL,M presents a larger value than the CL,F. Then, the kLa,M is selected as an input overall mass transfer coefficient to predict the dissolved ozone requirement in the ozone contactor.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bingham,Fluidity and Plasticity, McGraw-Hill, New York, 340 (1922).
Carphentier, J. C.,Advances in Chemical Engineering, Academic Press,11, New York (1981).
Choi, K.H. and Lee, W.K., “Behavior of Gas Bubbles in a Concentric Cylindrical Airlift Column,”Korean J. Chem. Eng.,9, 66 (1992).
Choi, K.H., “Hydrodynamic and Mass Transfer Characteristics of External-Loop Airlift Reactors without an Extension Tube above the Downcomer,”Korean J. Chem. Eng.,18, 240 (2001).
Clesceri, L. S., Greenburg, A. E., Trussel, R. R. and Franson, M.A.H.,Standard Methods for the Examination of Water and Wastewater, 16th Ed., APHA, AWWA, and WPCF, 399 (1985).
Danckwerts, P.V.,Gas-liquid Reaction, McGraw-Hill, New York, 17 (1970).
Kang, Y., Min, B. T., Nah, J. B. and Kim, S.D., “Effect of Floating Bubble Breakers on Gas Phase Holdup, Axial Dispersion and Mass Transfer in Continuous Bubble Columns,”HWAHAK KONGHAK,28, 560 (1990).
Kang, Y. S., Kim, J.W. and Lee, W.K., “Gas Holdup and Volumetric Mass Transfer Coefficient in a Bubble Column with Draft Tube,”HWAHAK KONGHAK,24, 371 (1986).
Koh, J. C., Kim, B. S., Lee, J. M. and Rhee, B. S., “Gas Holdup and Volumetric Mass Transfer Coefficient in Slurry Bubble Column of Acicular Goethite Suspension [I],”HWAHAK KONGHAK,27, 23 (1989).
Lee, J. E., Choi, W. S. and Lee, J.K., “A Study of the Bubble Properties in the Column Flotation System,”Korean J. Chem. Eng.,20, 943 (2003).
Lee, J. E. and Lee, J.K., “Effect of Microbubbles and Particle Size on the Particle Collection in the Column Flotation,”Korean J. Chem. Eng.,19, 703 (2002).
Park, H. S., Hwang, T. M., Oh, H. J. and Kang, J.W., “Characterization of Water for the Ozone Application Measuring Ozone Consumption Rate,”Korean Society of Env. Eng. J.,23, 1125 (2001).
Rhim, J.A., “Decomposition Characteristics and Overall Decomposition Rate Constant of Dissolved Ozone,”Korean Society of Env. Eng. J.,25, 1394 (2003).
Sotelo, J. L., Beltran, F. J., Benitez, F. J. and Beltran-Heredia, J., “Henry’s Law Constant for the Ozone-Water System,”Wat. Res.,23, 1239 (1989).
Yoon, J.H.,Decomposition of Microcystin-LR by Ozonation in Cylindrical Reactor, Ph. D. Dissertation, Pusan National University (1999).
Yoon, J.H., Rhim, J. A., Kim, Y. T., Park, T. J. and Kim, D.Y., “Decomposition Characteristics of Microcystin-LR by Ozonation,”Korean Society of Env. Eng. J.,21, 711 (1999).
Zhou, H. and Smith, D., “Ozone Mass Transfer in Water and Wastewater Treatment: Experimental Observation using a 2D Laser Particle Dynamics Analyzer,”Wat. Res.,34, 909 (2000).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Rhim, J.A., Yoon, J.H. Mass transfer characteristics and overall mass transfer coefficient in the ozone contactor. Korean J. Chem. Eng. 22, 201–207 (2005). https://doi.org/10.1007/BF02701485
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02701485