Abstract
An MPLC (Medium Pressure Liquid Chromatography) column was inhouse packed with an anion exchange silica gel (PAE 1000, Amicon) in order to carry out pulse response experiments to investigate MPLC column efficiency. Bovine serum albumin was isocratically eluted from the column with varying ionic strength of NaCl, and the chromatograms obtained were analyzed by the moment method. Broadening of the elution band was caused mostly by a longitudinal dispersion in our system, and no significant numerical differences in HETP with the velocity change were observed at the high ionic strength.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Ahn, S. H. and Chung, I. J., “pH Effect on the Separation of Chymotrypsin by Affinity Chromatography”Korean J. Chem. Eng.,2, 11 (1985).
Bungay, H. R. and Belfort, G., “Advanced Biochemical Engineering;” John Wiley & Sons, New York (1987).
Ghim, Y. S., “On the Performance of Liquid Chiomatography for the Separation of Glucose and Fructose” MS Thesis, KAIST (1980).
Kim, I. H., Kim, J. T. and Chung, B. H., “A Study of Protein Ion Exchange Chromatography Based on Plate Theory”Kor. J. Appl. Microbial. Biotechnol,23(4), 485 (1995).
Kim, I.H., Yune, S.W., Lee, S.M. and Song, J.Y, “Purification and Characterization of Recombinant Human Granulocyte-Macrophage Colony Stimulating Factor”Kor. J. Biological Response Modifiers,1(1), 105 (1991).
Ladish, M. R. and Kohlmann, K. L., “Recombinant Human Insulin”Biotechnol. Prog.,8,469(1992).
Liu, H.-C, “Membranebased Affinity Chromatography” Ph. D. Thesis, Univ. Cincinnati, p.20 (1993).
Park, I. S. and Suh, G. D., “Estimation of Mass Transfer Parameters in a Fixed Bed of Bidispersed Polymer Resin by Moment Method”,HWAHAK KONGHAK,22, 279 (1984).
Sakamoto, K., “Medium Pressure Liquid Chromatography”,Bioindustry,4(9), 751 (1987).
Sisson, W.G., Begovich, J.M., Byers, C.H. and Scott, C. D., “Continuous Chromatography”Chem Tech., Aug., 498 (1988).
Subramanian, G. (ed), “Preparative and Process-Scale Liquid Chromatography”, Ellis Horwood, New York (1991).
Wheelwright, S. M. (ed), “Protein Purification: Design and Scale-Up of Downstream Processing” Hanser, Munich (1991).
Yamamoto, S., Nakanish, K. and Matsno, R., “Ion-Exchange Chromatography of Proteins” Dekker, New York (1988).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, I.H., Kim, J.T. Pulse response test in medium pressure protein chromatography. Korean J. Chem. Eng. 15, 575–579 (1998). https://doi.org/10.1007/BF02698980
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02698980