Abstract
The effects of the horizontal connection length (0.1≤Lc≤0.5 m), the downcomer-to-riser cross-sectional area ratio (0.11≤Ad/Ar≤0.53) and the superficial gas velocity (0.02≤UG≤0.18 ms-1) on gas holdups in the riser and downcomer, the circulation liquid velocity, the mixing time, and the overall volumetric mass transfer coefficient were determined in external-loop airlift reactors without an extension tube above the downcomer [configuration (a)]. For otherwise fixed conditions, the absence of the extension tube strongly affected the hydrodynamic and mass transfer characteristics of external-loop airlift reactors. In contrast with the external-loop airlift reactor with the extension tube [configuration (b)], a large air pocket formed in the top horizontal connection and the surface aeration took place in the external-loop airlift reactor without the extension tube [configuration (a)]. As a result, the riser circulation liquid velocity in configuration (a) was slower than that in configuration (b). The riser and downcomer gas holdups, the mixing time and the overall volumetric mass transfer coefficient in configuration (a) were larger than those in configuration (b), respectively.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Akita, K., Nakanishi, O. and Tsuchiya, K.,“Turn-Around Energy Losses in an External-Loop Airlift Reactor,”Chem. Eng. Sci.,49, 2521 (1994).
Bello, R. A., Robinson, C. W. and Moo-Young, M.,“Liquid Circulation and Mixing Characteristics of Airlift Contactors,”Can. J. Chem. Eng.,62, 573 (1984).
Bello, R. A., Robinson, C. W. and Moo-Young, M.,“Gas Holdup and Overall Volumetric Oxygen Transfer Coefficient in Airlift Contactors,”Biotech. Bioeng.,27, 369 (1985a).
Bello, R. A., Robinson, C. W. and Moo-Young, M.,“Prediction of the Volumetric Mass Transfer Coefficient in Pneumatic Contactors,”Chem. Eng. Sci.,40, 53 (1985b).
Bentifraouine, C., Xuereb, C. and Riba, J. P.,“An Experimental Study of the Hydrodynamic Characteristics of External Loop Airlift Contactor,”J. Chem. Tech. Biotechnol.,69, 345 (1997a).
Bentifraouine, C., Xuereb, C. and Riba, J. P.,“Effect of Gas Liquid Separator and Liquid Height on the Global Hydrodynamic Parameters of External Loop Airlift Contactor,”Chem. Eng. J.,66, 91 (1997b).
Benyahia, F., Jones, L., Petit, S. and Plantaz, D.,“Mass Transfer Studies in Pneumatic Reactors,”Chem. Eng. Technol.,19, 425 (1996).
Chisti, M. Y. and Moo-Young, M.,“Airlift Reactors: Characteristics, Applications and Design Considerations,”Chem. Eng. Commun.,60, 195 (1987).
Chisti, M. Y. and Moo-Young, M.,“Hydrodynamics and Mass Transfer in Pneumatic Bioreactor Devices,”Biotechnol. Bioeng.,31, 487 (1988).
Choi, K. H.,“A Mathematical Model for Unsteady-State Oxygen Transfer in an External-Loop Airlift Reactors,”Korean J. Chem. Eng.,16, 441 (1999).
Choi, K. H. and Lee, W. K.,“Circulation Liquid Velocity, Gas Holdup and Volumetric Oxygen Transfer Coefficient in External Loop Airlift Reactors,”J. Chem. Tech. Biotechnol.,56, 51 (1993).
Choi, K. H., Chisti, M. Y. and Moo-Young, M.,“Influence of the Gas-Liquid Separator Design on Hydrodynamic and Mass Transfer Performance of Split-Channel Airlift Reactors,”J. Chem. Tech. Biotechnol.,62, 327 (1995a).
Choi, K. H., Chisti, M. Y. and Moo-Young, M.,“Split-Channel Rectangular Airlift Reactors: Enhancement of Performance by Geometric Modifications,”Chem. Eng. Commun.,138,171 (1995b).
Choi, K. H.,“Circulation Liquid Velocity in External-Loop Airlift Reactors,”Korean J. Chem. Eng.,13, 379 (1996).
Choi, K. H.,“Circulation of Gas and Liquid Phases in External-Loop Airlift Reactors,”Chem. Eng. Commun.,160, 103 (1997).
Choi, K. H., Han, B. H. and Lee, W. K.,“Effect of Horizontal Connection Pipe Length on Gas Holdup and Volumetric Oxygen Transfer Coefficient in External Loop Airlift Reactor,”HWAHAK KONG-HAK,28, 220 (1990).
Gavrilescu, M. and Tudose R. Z.,“Mixing Studies in External-Loop Airlift Reactors,”Chem. Eng. J.,66, 97 (1997).
Kemblowski, Z., Przywarski, J. and Diab, A.,“An Average Gas Holdup and Liquid Circulation in Airlift Reactors with External Loop,”Chem. Eng. Sci., 48,4023 (1993).
McMamamey, W. J., Wase, D. A. J., Raymahasay, S. and Thaynithy, K.,“The Influence of Gas Inlet Design on Hold-up Values for Water and Various Solutions in a Loop-type Airlift Fermenter,”J. Chem. Tech. Biotechnol.,34B, 151 (1984).
Mercer, D. G.,“Flow Characteristics of a Pilot-Scale Airlift Fermentai,”Biotech. Bioeng.,23, 2421 (1981).
Merchuk, J. C. and Siegel, H.,“Air-Lift Reactors in Chemical and Biological Technology,”J. Chem. Tech. Biotechnol.,41, 105 (1988).
Merchuk, J. C. and Stein, Y.,“Local Holdup and Liquid Velocity in Air-Lift Reactors,”AIChEJ.,27, 377 (1981).
Merchuk, J. C.,“Gas Hold-Up and Liquid Velocity in a Two-Dimensional Air Lift Reactor,”Chem. Eng. Sci.,41,11 (1986).
Park, C. J.,“Hydrodynamic Characteristics of Air-Lift Activated Carbon Slurry Column with External Looping,”Korean J. Chem. Eng.,16, 694 (1999).
Petrovic, D. L. J., Posarac, D. and Dudukovic, A.,“Prediction of Mixing Time in Airlift Reactors,”Chem. Eng. Comm.,133,1 (1995).
Popovi’c, M. and Robinson, C. W.,“External-Circulation-Loop Airlift Bioreactors: Study of the Liquid Circulation Velocity in Highly Viscous Non-Newtonian Liquids,”Biotech. Bioeng.,32, 301 (1988).
Popovíc, M. and Robinson, C. W.,“The Specific Interfacial Area in External-Circulation-Loop Airlifts and a Bubble Column-I. Aqueous Sodium Sulphite Solution,”Chem. Eng. Sci.,42, 2811 (1987).
Rand, M. G., Greenberg, A. E. and Taras, M. J., (eds.),“Standard Methods for the Examination of Water and Wastewater,” 14th Ed., American Public Health Association, Washington, p. 87 (1975).
Siegel, M. H., Merchuk, J. C. and Schugerl, K.,“Air-Lift Reactor Analysis: Interrelationships between Riser, Downcomer, and Gas-Liquid Separator Behavior, Including Gas Recirculation Effects,”AIChE J.,32,1585 (1986).
Snape, J. B., Zahradnik, J., Fialova, M. and Thomas, N. H.,“Liquid-Phase Properties and Sparger Design Effects in an External-Loop Airlift Reactor,”Chem. Eng. Sci.,50, 3175 (1995).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Choi, K.H. Hydrodynamic and mass transfer characteristics of external-loop airlift reactors without an extension tube above the downcomer. Korean J. Chem. Eng. 18, 240–246 (2001). https://doi.org/10.1007/BF02698466
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02698466