Abstract
High-performance membrane chromatography (HPMC) is a very effective Chromatographic method that combines the advantages of both membrane technology and column chromatography. In this work, proteins (myoglobin, conalbumin and soybean trypsin inhibitor) were separated by HPMC. The separation mechanism involved anionexchange, and the stationary phases were used anion CIM DEAE and QA disks (12x3 mm). Two types of mobile phase, buffer A (20 mM Tris-HCl, pH 7.4) and buffer B (buffer A+1 M NaCl) were used. As the amount of sodium chloride dissolved in buffer linearly increased, the retention time shortened and the resolution of the components was greatly improved. The optimum mobile phases and operating conditions were experimentally determined. From the experimental results, the proteins were separated within 2 min at a mobile phase flow rate of 4 ml/min.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Ales, P., Milos, B., Janez, J. and Ales, S., “High-Performance Membrane Chromatography of Small Molecules”,Anal. Chem,71, 2986 (1999).
Ales, P., Milos, B., Janez, J. and Ales, S., “Isocratic Separations on Thin Glycidyl Methacrylate-ethylenedimethacrylate Monoliths”,J. Chromatogr.A,848, 51 (1998).
Boris, G., Belenkii, V. G. and Maltsev, “High-Performance Membrane Chromatography”,BioTechniques,18, 288 (1995).
Catherine, C., “Purification of Proteins by Membrane Chromatography”,J. Chem. Technol Biotechnol.,71, 95 (1998).
Dubinina, N. I., Kurenbin, O. I. and Tennikova, T. B., “Peculiarties of Gradient Ion-exchange High-performance Liquid Chromatography of Proteins”,J. Chromatogr. A,753, 217 (1996).
Elisabeth, H., “Prediction of Protein Retention at Gradient Elution Conditions in Ion-exchange Chromatography”,J. Chromatogr. A,852, 351 (1999).
Galina, A., Tishchenko, M. B., Jici, S. and Tomas, B., “Effect of Salt Concentration Gradient on Separation of Different Types of Specific Immunogobulins by Ion-exchange Chromatography on DEAE Cellulose”,J. Chromatogr. B,706,157 (1998).
Joseph, A., Gerstner, R. H. and Steven M. Cramer, “Membrane Chromatographic Systems for High-throughput Protein Separations”,J. Chromatogr.,596,173 (1992).
Keith Roper, D. and Edwin N. Lightfoot, “Separation of Biomolecules using Adsorptive Membranes”,J. Chromatogr. A,702, 3 (1995).
Laure, G., Berreux, R. F. and Tatiana, B. T., “Comparison of Antibody Binding to Immobilized Group Specific Affinity Ligands in High Performance Monolith Affinity Chromatography”,J. Pharm. Biomed Anal.,24, 95 (2000).
Lee, Y W., So, M.S, Lee, J. W., Chung, S. T. and Row, K. H., “Retention Models of Capacity Factor with Different Compositions of Organic Modifier in RE-HPLC”,J. of Chem. Eng.,13,578 (1996).
Lian, S. and David, J. Anderson, “Effect of Buffer Concentration on Gradient Chromatofocusing Performance Separating Proteins on a High-performance DEAE Column”,J. Chromatogr. A,909,191 (2001).
Michael, B., Tennikov, N, Gazdina, V, Tatiana, B. and Tennikova, F S., “Effect of Porous Structure of Macroporous Polymer Supports on Resolution in High-performance Membrane Chromatography of Proteins”,J. Chromatogr. A,798, 55 (1998).
Peter, R., Levison, A. K. and Hopkins, P. H., “Influence of Column Design on Process-scale Ion-exchange ChromatographyJ. Chromatogr. A,865, 3 (1999).
Peter, R, Levison, S. E., Badger, P. H., Martin, I, Davies, I. J. and Bruce, V. G., “New Approaches to the Isolation of DNA by Ion-exchange ChromatographyJ. Chromatogr. A,827, 337 (1998).
Shuichi, Y. and Eiji, M., “Retention Behavior of Very Large Biomolecules in Ion-exchange Chromatography”,J. Chromatogr. A,852,25 (1999).
Shuichi, Y, Peter, K., Watler, D. F. and Oliver, K., “Characterization of Unstable Ion-exchange Chromatographic Separation of Proteins”,J. Chromatogr. A,852, 37 (1999).
Sridhar, P., “Design of Affinity Membrane Bioseparations”,Chem. Eng. Technol.,19,398 (1996).
Vodopivec, M., Berovic, M., Jancar, J., Podgornik, A. and Strancar, A., “Application of Convective Interaction Media disks with Immobilized Glucose Oxidase for On-line Glucose Measurements”,Analytica Chimica Acta,407, 105 (2000).
Wensheng, X. and Fred, E. R., “Protein-protein Interactions on Weakcation-exchange Sorbent Surfaces During Chromatographie Separations”,J. Chromatogr. A,828, 357 (1998).
Xianfang, Z. and Eli, R., “Cross-linked Macroporous Chitosan Anion-exchange Membrane for Protein Separations”,Journal of Membrane Science,148,195 (1998).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hong, S.B., Row, K.H. Protein separation by high-performance membrane chromatography. Korean J. Chem. Eng. 19, 314–317 (2002). https://doi.org/10.1007/BF02698421
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02698421