Abstract
The proposal of the role of mechanical forces as a localizing factor of atherosclerosis has led many researchers to investigate their effects on vascular endothelial cells. Most previous efforts have concentrated on either the fluid shear stress, which results from the flow of blood, or the circumferential “hoop” stretch, which results from the expansion of the artery during the cardiac cycle. In fact, arterial endothelial cells are subjected to both fluid shear stress and cyclic hoop stretchin vivo. Therefore, a more complete investigation of mechanical phenomena on endothelial cell behavior should include both kinds of mechanical stimuli. This study was undertaken to design an experimental apparatus that could subject cultured vascular endothelial cells to simultaneous physiologic levels of both shear stress and cyclic hoop stretch. The experimental apparatus consists of four cylindrical elastic tubes so that the following conditions may be studied: (a) static conditions; (b) shear stress only; (c) hoop stretch only; and (d) shear stress and hoop stretch. In order to establish the functional capabilities of the apparatus, bovine pulmonary artery endothelial cells were cultured in the tubes, and their morphology and f-actin structur were observed with confocal microscopy. The cells remained healthy and attached to the walls throughout the 24 hr experiment. Preliminary results indicated that the alignment of endothelial cells subjected to shear stress was significantly enhanced by the addition of hoop strain.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Banes, A.J. Mechanical strain and the mammalian cell. In: Frangos, J.A., ed. Physical forces and the mamalian cell. New York: Academic Press; 1993: pp. 81–123.
Berthiaume, F.; Frangos, J.A. Effects of flow on anchorage-dependent mammalian cells-secreted products. In: Frangos, J.A., ed. Physical forces and the mammalian cell. New York: Academic Press; 1993: pp. 139–192.
Carosi, J.A.; Eskin, S.G.; McIntire, L.V. Cyclical strain effects on production of vasoactive materials in cultured endothelial cells. J. Cell. Physiol. 151:29–36; 1992.
He, X.; Ku, D.N.; Moore, J.E.; Jr. Simple calculation of the velocity profiles for pulsatile flow in a blood vessel using Mathematica. Ann. Biomed. Eng. 21:45–49; 1993.
Ives, C.L.; Eski, S.G.; McIntire, L.V. Mechanical effects on endothelial cell morphology: in vitro assessment. In Vitro Cell. Dev. Biol. 22(9):500–507; 1986.
Levesque, M.J.; Nerem, R.M. The elongation and orientation of cultured endothelial cells in response to shear stress. ASME J. Biomech. Eng. 107:341–347; 1985.
Panton, R.L. Incompressible flow. New York: John Wiley & Sons; 1984.
Tardy, Y.; Meister, J.J.; Perret, F.; Brunner, H.R.; Arditi, M. Noninvasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethy smographic measurements. Clin. Phys. Physiol. Meas. 12(1): 39–54; 1991.
Williams, J.L.; Chen, J.H.; Belloli, D.M. Strain fields on cell stressing devices employing clamped circular elastic diaphragms as substrates. ASME J. Biomech. Eng. 114: 377–384; 1992.
Zand, T.; Underwood, J.M.; Nunnari, J.J.; Majno, G.; Joris, I. Endothelium and “silver lines.” An electron microscopic study. Virchows Arch. Pathol. Anat. 395:133–144; 1982.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Moore, J.E., Bürki, E., Suciu, A. et al. A device for subjecting vascular endothelial cells to both fluid shear stress and circumferential cyclic stretch. Ann Biomed Eng 22, 416–422 (1994). https://doi.org/10.1007/BF02368248
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02368248