Abstract
The aim of this study was to investigate the suitability of picosecond lasers for hard-tissue preparation. Using scanning electron microscopy (SEM) and histological studies, the quality of ablation was examined. There was no thermal or mechanical damage observed. The ablation rates of enamel, dentine and carious enamel and the temperature rise during tissue removal were measured. Using a fast silicon photodiode, the lifetime of the plasma was determined to be 11±3 ns (Nd-YLF, 1.25 mJ pulse−1, pulse duration 30 ps). In order to achieve a better understanding of the ablation process, plasma parameters such as electron density [(5±3)×1017 cm−3] and excitation temperature (4500±2000 ℐg, Nd-YLF, 0.3 mJ pulse−1) were obtained from emission spectra. By examining the line width of singly ionized calcium lines, a difference was found in the ablation of healthy or artificially demineralized enamel, thus allowing the selective removal of caries.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Boulnois JL. Photophysical processes in recent medical laser developments: a review.Lasers Med Sci 1986,1:47–66
Stern RH, Sognnaes RF. Laser beam effect on dental hard tissues.J Dent Res 1964,43:873
Goldman L, Hornby P, Mayer R, Goldman B. Impact of the laser on dental caries.Nature 1964,203:417
Stern RH, Vahl J, Soggnaes RF. Lased enamel: ultrastructural observations of pulsed carbon dioxide laser effects.J Dent Res 1972,51:455
Frame JW. Carbon dioxide laser surgery for benign oral lesions.Br Dent J 1985,158:125
Zach K, Cohen G. Pulp response to externally applied heat.Oral Surg 1965,19:515–30
Frentzen M, Koort HJ, Kramer B. Thermische effekte bei der präparation von zahnhartgeweben mit verschiedenen lasersystemen.Dtsch Zahnärztl Z 1990,45:240–2
Keller U, Hibst R. Zur ablativen Wirkung des Er:YAG Lasers auf schmelz und dentin.Dtsch Zahnärztl Z 1989,44:600–2
Hibst R, Keller U. Experimental studies of the application of the Er:YAG laser on dental hard substances I.Lasers Surg Med 1989,9:338–44
Keller U, Hibst R. Experimental studies of the application of the Er:YAG laser on dental hard substances II light microscopic and SEM investigations.Lasers Surg Med 1989,9:345–51
Liesenhoff T, Bende T, Lenz H, Seiler T. Grundlagen zur anwendung des excimer-lasers in der zahnheilkunde.Dtsch Zahnärztl Z 1990,45:14–6
Frentzen M, Koort HJ. Lasertechnik in der zahnheilkunde.Dtsch Zahnärztl Z 1991,46:443–54
Niemz MH, Eisenmann L, Pioch T. Vergleich von drei lasersystemen zur abtragung von Zahnschmelz.Schweiz Monatsschr Zahnmed 1993,103:1252–6
Rechmann P, Hennig T, Kaufmann R. Laser in der Zahnhartsubstanzabtragung.Zahnärztl Welt 1992,101:150–60
Niemz MH. Investigation and spectral analysis of the plasma-induced ablation mechanism of dental hydroxyapatite.Appl Phys B 1994,58:273–81
Pioch T, Niemz M, Mindermann A, Staehle HJ. Schmelzablation durch laserimpulse im pikosekundenbereich.Dtsch Zahnärztl Z 1994,49:163–5
Haltenhoff U.Mikrotomie in Biologie und Medizin. Nussloch, Germany: Fr. Jung, 1979
Weast RC, Astle MJ.CRC Handbook of Chemistry and Physics. Boca Raton, Florida: CRC Press Inc., 1983
Huddlestone RH, Stanley LL (eds).Plasma Diagnostic Techniques. New York: Academic Press, 1965
Griem HR.Spectral Line Broadening by Plasmas. New York: Academic Press, 1974
Woltz LA, Hooper CF Jr. Calculation of spectral line profiles of multielectron emitters in plasmas.Phys Rev A 1988,38:4766–71