Abstract
A two-circuit compression scheme for a high-power pulse generator and a method for its calculation taking into account the hysteresis loop of each nonlinear inductance are proposed. It is shown that the use of two thyratrons terminating in a compression scheme with nonlinear chokes makes it possible to increase the energy in a pulse taken off the load by no less than 50%.
Article PDF