Abstract
The contraceptive efficacy and clinical performance of Nova-T and TCu200Ag were studied in a randomized comparative study with 819 interval acceptors. The 1- and 2-year gross termination rates were evaluated by means of the life-table method. The 12-month pregnancy rates were 1.0 per 100 women with Nova-T and 3.0 per 100 women with TCu200Ag. The preliminary 2-year rates were 1.7 and 5.5 per 100 respectively (p=0.037). Rates of expulsion, medican and personal removals were not significantly different for the two devices. Continuation rates for the first year were 89.4 and 90.5 per 100 respectively.
Résumé
L'efficacité anticonceptionnelle et la performance clinique des stérilets Nova-T et TCu200Ag ont été évaluées dans le cadre d'une étude comparative randomisée portant sur 819 femmes ayant accepté des intervalles d'utilisation. On a évalué les taux de terminaison totaux sur 1 et 2 ans par la méthode des tables de survie. Dans une période de 12 mois, les taux de grossesse ont égalé 1% chez les femmes portant le Nova-T et 3% chez les femmes portant le TCu200Ag. Les taux préliminaires pour 2 ans ont respectivement atteint 1,7 et 5,5% (p=0,037). Les taux d'expulsion, ou d'extraction pour motifs médicaux et personnels n'ont pas différé sensiblement pour les deux types de stérilets. Durant la première année, les taux de continuation d'emploi respectifs on été de 89,4 et 90,5%.
Resumen
La eficacia anticonceptiva y los resultados clínicos del Nova-T y el TCu200Ag fueron estudiados en 810 aceptantes en un estudio comparativo randomizado. Las tasas brutas de terminación a uno y dos años fueron evaluadas por medio de la tabla de vida. La tasa de embarazos a 12 meses fue de 1,0 por cien mujeres con Nova-T y 3,0 con TCu200Ag. Las tasas preliminares a dos años fueron 1,7 y 5,5 respectivamente (p=0,037). Las tasas de expulsión y de remociones por razones médicas y personales no fueron significativamente diferentes para los dos dispositivos. Las tasas de continuación para el primer año fueron 89,4 y 90,5 por ciento respectivamente.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
LuukkainenT., AllonenH., NielsenN. C., NygrenK. G. and PyöräläT. (1983). Five years' experiences of intrauterine contraception with the Nova-T and the Copper T200.Am. J. Obstet. Gynecol.,147, 885–892
Batár, I., Lamp'e, L., Rákoczi, I., Gáti, I. and Allonen, H. (1985). A Hungarian comparison of Nova-T and TCu200Ag IUDs.5th World congress on Human Reproduction, Abstract 285, 22–26 September 1985, Athens, Greece
Timonen, H., Nylander, P., Kivijarvi, A., Hirvonen, E., Kajanoja, P., Kaivola, L., Kotilainen, A., Savia, E., Saure, A., Lonnblad, R., Terava, M., Venhola, M., Mannikko, H., Kaar, K. and Vierola, H. (1982). Comparative performance of three copper IUDs (MLCu375, Fincoid and Nova-T) after one year's follow-up in randomized multicenter trial.Contracept. Deliv. Syst.,3, Abstract No. 226
LuukkainenT., NielsenN. C., NygrenK.-G., PyöräläT. and KosonenA. (1979). Randomized comparison of clinical performance of two copper-releasing IUDs, Nova-T and Copper T200 in Denmark, Finland and Sweden.Contraception,19, 1–9.
TietzeC. and LewitS. (1973). Recommended procedures for the statistical evaluation of intrauterine contraception.Stud. Fam. Plann.,4, 35–42
AzenS. P., RoyS., PikeM. C., CasagrandeJ. and MishellR. D. (1977). A new procedure for the statistical evaluation of intrauterine contraception.Obstet. Gynecol. 128, 329–335
HersonR. (1975). Standardization of cumulative failure rates.Demography,12, 467–470
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kožuh, M., Andolsěk, L. & Allonen, H. A randomized comparative trial of Nova-T and TCu200Ag in Yugoslavia. Adv Contracept 2, 31–36 (1986). https://doi.org/10.1007/BF01849295
Issue Date:
DOI: https://doi.org/10.1007/BF01849295