Summary
The contents of all individual chlorobiphenyls in two technical PCB mixtures (Clophen A 30 and Clophen A 60) were investigated by capillary gas chromatography. These two commercial products contain virtually all polychlorinated biphenyls (PCB) occurring in environmental samples.
The introduction of the samples was carried out by a direct injection without discrimination. In spite of the use of capillaries of high separation efficiency overlaps of some components could not be avoided. These fractions were passed over with the aid of a column switching to a second capillary column of a different polarity, on which they were separated.
For detection an FID was used, which shows practically the same response for chlorinated biphenyls with the same number of chlorine atoms, however, not for different chlorination degrees. For correction of the different FID response calibration factors were determined by means of a solution of individual PCB's with 1 to 10 chlorine atoms.
Zusammenfassung
Mit Hilfe der Capillar-GC wurden die Anteile aller einzelnen Chlorbiphenyle in zwei technischen PCB-Gemischen (Clophen A 30 und Clophen A 60) ermittelt. In diesen beiden Handelsprodukten sind praktisch alle in Umweltproben vorkommenden polychlorierten Biphenyle (PCB) enthalten.
Die Probenaufgabe erfolgte durch eine diskriminierungsfreie Direktinjektion. Trotz der Verwendung von Capillaren hoher Trennleistung lie\en sich überlagerungen einiger Komponenten nicht vermeiden. Diese Fraktionen wurden mit Hilfe einer SÄulenschaltung in eine zweite CapillarsÄule anderer PolaritÄt geleitet, auf der sie sich trennen lie\en.
Zur Detektion diente ein FID, der für chlorierte Biphenyle mit gleicher Zahl an Cl-Atomen praktisch die gleiche Anzeigeempfindlichkeit hat, nicht jedoch für unterschiedliche Chlorierungsgrade. Zur Korrektur dieses unterschiedlichen FID-Responses wurden mit Hilfe einer Lösung von einzelnen PCB mit 1 bis 10 Cl-Atomen pro Molekül Eichfaktoren ermittelt.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Literatur
Sissons D, Welti D (1971) J Chromatog 60:15
Webb RG, McCall AC (1972) J Assoc Off Anal Chem 55:746
Tas AC, Kleipool RJC (1972) Bull Environ Contam Toxicol 8:32
Jensen S, Sundström G (1974) Ambio 3:70
Schulte E, Acker L (1974) Fresenius Z Anal Chem 268:260
Schulte E, Acker L (1974) Naturwissenschaften 61:79
Acker L, Schulte E (1975) Bericht an die Deutsche Forschungsgemeinschaft über das Forschungsvorhaben „Untersuchung zum Vorkommen von Chlorkohlenwasserstoffen in der Nahrung und im Körper des Menschen und zur Herkunft der polychlorierten Biphenyle“
Becker G, Schulte E (1976) Lebensmittelchem Gerichtl Chem 30:101
Ballschmiter K, Zell M (1980) Fresenius Z Anal Chem 302:20
Mullin M, Sawka G, Safe L, McCrindle S, Safe S (1981) J Anal Toxicol 5:138
Malisch R (1981) Diss Univ Münster
Bush B, Connor S, Snow J (1982) J Assoc Off Anal Chem 65:555
Schulte E (1983) Praxis der Kapillar-Gas-Chromatographie. Springer, Berlin Heidelberg New York
Grob K, Grob, K Jr (1978) J Chromatog 151:311
Schulte E, Acker E (1980) Nahrung 24:577
Müller F, Oreans M Analytical Application Note No. 282 (Siemens)
Strubert W, Müller F, Hövermann W (1979) Int Lab 9:149
Hutzinger O, Safe S, Zitko V (1974) The Chemistry of PCB's. CRC Press, Cleveland, p 3
Author information
Authors and Affiliations
Additional information
Danksagung. Herrn Prof. Dr. L. Acker danken wir für die Anregungen beim Verfassen des Manuskripts.
Rights and permissions
About this article
Cite this article
Schulte, E., Malisch, R. Berechnung der wahren PCB-Gehalte in Umweltproben. Z. Anal. Chem. 314, 545–551 (1983). https://doi.org/10.1007/BF00474844
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00474844