Abstract
The ability of a flow cytometer to rapidly assess microbial viability was investigated using three vital stains: rhodamine 123 (Rh123); 3,3'-dihexyloxacarbocyanine iodide [DiOC6(3)] and fluorescein diacetate (FDA). Rh123 was found to clearly differentiate viable from non-viable bacteria. The methodology for staining bacteria with this dye was optimised. Rh123 was shown to stain and discriminate several different species of viable bacteria although this was not universal. Viable cells of Bacillus subtilis were found to stain better with FDAthan with Rh123. The results demonstrate the ability of flow cytometry to rapidly detect and estimate the viability of bacterial populations.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Adams A, Bundy A, Thompson K, Horne MT (1988) The association between virulence and cell surface characteristics of Aeromonas salmonicida. Aquaculture 69:1–14
Bercovier H, Resnick M, Kornitzer D, Levy L (1987) Rapid method for testing drug-susceptibility of Mycobacteria sp. and Gram-positive bacteria using rhodamine 123 and fluorescein diacetate. J Microbiol Methods 7:139–142
Chrzanowski TH, Crotty RD, Hubbard JG, Welch RP (1984) Applicability of the fluorescein diacetate method of detecting active bacteria in freshwater. Microb Ecol 10:179–185
Darzynkiewicz Z, Traganos F, Staiano-Coico L, Kapuscinski J, Melamed MR (1982) Interactions of rhodamine 123 with living cells studied by flow cytometry. Cancer Res 42:799–806
Fry JC (1990) Direct methods and biomass estimation. Methods Microbiol 22:41–85
Johnson LV, Walsh ML, Chen LB (1980) Localisation of mitochondria in living cells with rhodamine 123. Proc Natl Acad Sci USA 77:990–994
Lundgren B (1981) Fluorescein diacetate as a stain of metabolically active bacteria in soil. Oikos 36:17–22
Mason CA, Hamer G, Bryers JD (1986) The death and lysis of microorganisms in environmental processes. FEMS Microbiol Rev 39:373–401
Matsuyama T (1984) Staining of bacteria with rhodamine 123. FEMS Microbiol Lett 21:153–157
Patchett RA, Back JP, Kroll RG (1990) Enumeration of bacteria by use of a commercial flow cytometer. J Appl Bacteriol 69:xxiii
Pinder AC, Purdy PW, Poulter SAG, Clark DC (1990) Validation of flow cytometry for rapid enumeration of bacterial concentrations in pure cultures. J Appl Bacteriol 69:92–100
Resnick M, Schuldiner S, Bercovier H (1985) Bacterial membrane potential analyzed by spectroflourocytometry. Curr Microbiol 12:183–186
Roszak DB, Colwell RR (1987) Survival strategies of bacteria in the natural environment. Microbiol Rev 51:365–379
Ryan TA, Jointer BL, Ryan BI (1976) Minitab student handbook. Duxbury Press, North Scituate
Shapiro HM (1988) Practical flow cytometry. Liss, New York
Shapiro HM (1990a) Cell membrane potential analysis. Methods Cell Biol 33:25–35
Shapiro HM (1990b) Flow cytometry in laboratory microbiology: new directions. ASM News 56:584–588
Skowronek P, Krummeck G, Haferkamp O, Rodel G (1990) Flow cytometry as a tool to discriminate respiratory-competent and respiratory-deficient yeast cells. Curr Genet 18:265–266
Sokal RR, Rohlf FJ (1982) Biometry 2edn. Freeman and Co, New York
Author information
Authors and Affiliations
Additional information
Correspondence to: J. P. Diaper
Rights and permissions
About this article
Cite this article
Diaper, J.P., Tither, K. & Edwards, C. Rapid assessment of bacterial viability by flow cytometry. Appl Microbiol Biotechnol 38, 268–272 (1992). https://doi.org/10.1007/BF00174481
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00174481