The aim of this study is to evaluate the functional and cell biological applicability of a two-ply nerve guide constructed of a PLLA/PCL (i.e. poly-l-lactide and poly-ε-caprolactone) copolymer. To do so, we performed a cytotoxicity test, a subcutaneous biodegradation test and an in situ implantation study in the sciatic nerve of the rat. The nerve guide copolymer was found to be non-toxic, according to ISO/EN standards, and it showed a mild foreign body reaction and complete fibrous encapsulation after implantation. Onset of biodegradation of the inner layer was seen after one month of implantation. After 18 months of implantation complete fragmentation was observed, as well as a secondary inflammatory response characterized by foreign body giant cell activity and phagocytosis of polymer debris. Recovery of both motor and sensory nerve function was observed in all nerve guides.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
N. Suematsu, Mircosurg. 10 (1989) 71.
G. Lundborg et al., Exp. Neurol. 76 (1982) 361.
G. Lundborg et al., Scand. J. Plastic Reconstructive Hand-Surg. 25 (1991) 79.
G. Lundborg et al., J. Neuropathol. Exp. Neurol. 41 (1982) 412.
M. Merle et al., Microsurg. 10 (1989) 130.
B. R. Seckel et al., Plastic Reconstructive Surg. 78 (1986) 793.
B. G. Uzman and G. M. Villegas, J. Neurosci. Res. 9 (1993) 157.
N. H. Chi and D. Dahl, 79 (1983) 245.
P. G. Cordeiro et al., Plastic Reconstructive Surg. 83 (1989) 1013.
R. D. Keeley et al., J. Reconstructive Microsurg. 7 (1991) (2) 93.
W. E. KUHN and J. L. HALL, in “Modern developments in powder metallurgy”, edited by H. H. Hausener and P. W. Taubenblat, American Powder Metallurgy Institute, Princeton, NJ) p. 279.
P. H. Robinson et al., Microsurg. 12 (1991) 412.
A. L. Dellon and S. E. Mackinnon, Plastic Reconstructive Surg. 82 (1988) 849.
E. Nyilas et al., Trans. Amer. Soc. Intern. Artificial Organs 29 (1983) 307.
S. E. Mackinnon, Annls Plastic Surg. 22(3) (1989) 257.
B. R. Seckel et al., Plastic Reconstructive Surg. 78 (1984) 793.
S. E. Mackinnon and A. L. Dellon, J. Reconstructive Microsurg. 6(2) (1990) 117.
H. Molander et al., Muscle Nerve 5 (1982) 54.
H. Molander et al., Biomaterials 4 (1983) 276.
D. W. Grijpma, G. J. Zondervan and A. J. Pennings, Polymer Bull. 25 (1991) 327.
H. J. Hoppen et al., Biomaterials 11(2) (1990) 286.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Den Dunnen, W.F.A., Schakenraad, J.M., Zondervan, G.J. et al. A new PLLA/PCL copolymer for nerve regeneration. J Mater Sci: Mater Med 4, 521–525 (1993). https://doi.org/10.1007/BF00120133
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00120133