Abstract
Uniformity is a key feature of state-of-the-art infrared focal planed array (IRFPA) and infrared imaging system. Unlike traditional infrared telescope facility, a ground-based infrared radiant characteristics measurement system with an IRFPA not only provides a series of high signal-to-noise ratio (SNR) infrared image but also ensures the validity of radiant measurement data. Normally, a long integration time tends to produce a high SNR infrared image for infrared radiant characteristics radiometry system. In view of the variability of and uncertainty in the measured target’s energy, the operation of switching the integration time and attenuators usually guarantees the guality of the infrared radiation measurement data obtainted during the infrared radiant characteristics radiometry process. Non-uniformity correction (NUC) coefficients in a given integration time are often applied to a specified integration time. If the integration time is switched, the SNR for the infrared imaging will degenerate rapidly. Considering the effect of the SNR for the infrared image and the infrared radiant characteristics radiometry above, we propose a-wide-dynamic-range NUC algorithm. In addition, this essasy derives and establishes the mathematical modal of the algorithm in detail. Then, we conduct verification experiments by using a ground-based MWIR(Mid-wave Infared) radiant characteristics radiometry system with an Ø400 mm aperture. The experimental results obtained using the proposed algorithm and the traditional algorithm for different integration time are compared. The statistical data shows that the average non-uniformity for the proposed algorithm decreased from 0.77% to 0.21% at 2.5 ms and from 1.33% to 0.26% at 5.5 ms. The testing results demonstrate that the usage of suggested algorithm can improve infrared imaging quality and radiation measurement accuracy.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
S. E. Godoy et al., Applied Optics 47, 5894 (2008).
U. Sakoglu et al., Proc. SPIE 5558, 69 (2004).
Gutschwager et al., Appl. Opt. 54, 10599 (2015).
V. F. Paz et al., Light Science & Applications 1, e36 (2012).
A. F. Milton et al., Optical Engineering 24, 855 (1985).
Y. Cao et al., Applied Optics 52, 6266 (2013).
D. R. Pipa et al., IEEE Transactions on Image Processing A Publication of the IEEE Signal Processing Society 21, 4758 (2012).
E. Vera et al., Optics Letters 36, 352 (2011).
M. J. Booth et al., Light Science & Applications 3, e165 (2014).
C. Zuo et al. Optik - International Journal for Light and Electron Optics 123, 833 (2012).
Jin et al. Infrared Physics & Technology 78, 1 (2016).
M. Yan et al., Light Science & Applications, 6, e17076 (2016).
N. Meitav et al. Light Science & Applications, 5, e16048 (2016).
Sheng-Hui et al., J. Opt. Soc. Am. A Opt. Image Sci. Vis. 33, 938 (2016).
C. Zuo et al., Optical Review 18, 197 (2011).
M. Ochs et al., Infrared Physics & Technology, 53, 112 (2010).
J. Zhang et al., Light Science & Applications 7, 17180 (2018).
W. W. Hauswirth et al., Journal of Vision 9, 27 (2009).
Z. Liu et al., Infrared Physics & Technology 76, 667 (2016).
W. Qian et al., Applied Optics, 50, 1 (2011).
C. C. Hou et al., Light Science & Applications 7, 17170 (2018).
J. Zhao et al., Optics Communications 296, 47 (2013).
H. X Zhou et al., Infrared Physics & Technology 53, 295 (2010).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cai, LH., He, FY., Chang, ST. et al. A Wide Dynamic Range NUC Algorithm for IRCS Systems. J. Korean Phys. Soc. 73, 1821–1826 (2018). https://doi.org/10.3938/jkps.73.1821
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.73.1821