Abstract
A sensitive non-derivatization method for the determination of the highly polar compound 3-aminopiperidine was developed using a mixed-mode column combined with a charged aerosol detector (CAD). Chromatographic conditions, including the type of detector, separation mode, and mobile phase composition, were optimized to achieve high sensitivity towards and sufficient retention of 3-aminopiperidine. Compared to the precolumn derivatization UV method, the current method showed higher recovery and greater simplicify. High sensitivity (LOQ <2.73 μg mL−1) and good precision (RSD of peak area <2%) were also observed in the current method. Furthermore, the parameters such as buffer solution and column bleed that affected the sensitivity of the CAD were investigated. Finally, the current method was applied for the determination of 3-aminopiperidine in linagliptin samples. This is a new non-derivative for the determination of 3-aminopiperidine, and constitutes a novel application of the CAD for the quantitative analysis of highly polar basic compounds.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
A. Chattopadhyay, R. Rukmini, S. Mukherjee, Biophys. J., 1996, 71, 1952.
Z.-W. Lai, C. Li, J. Liu, L. Kong, X. Wen, H. Sun, Eur. J. Med. Chem., 2014, 83, 547.
Z. Long, Z. Guo, X. Xue, X. Zhang, X. Liang, J. Sep. Sci., 2013, 36, 3845.
Z. Long, Z. Guo, X. Xue, X. Zhang, L. Nordahl, X. Liang, Anal. Chim. Acta, 2013, 804, 304.
D.C. Johnson, D. Dobberpuhl, R. Richard, P. Vandeberg, J. Chromatogr. A, 1993, 640, 79.
Chinese Pharmacopoeia Commission, "Pharmacopoeia of the People's Republic of China", 2015, Vol. 1, Medical Science Press, Beijing, China, 397.
Y. Liu, X. Xue, Z. Guo, Q. Xu, F. Zhang, X. Liang, J. Chromatogr. A, 2008, 1208, 133.
Z. Guo, C. Wang, T. Liang, X. Liang, J. Chromatogr. A, 2010, 1217, 4555.
J. Wei, A. Shen, H. Wan, J. Yan, B. Yang, Z. Guo, F. Zhang, X. Liang, J. Sep. Sci., 2014, 37, 1781.
K. Li, W. Zhu, Q. Fu, Y. Ke, Y. Jin, X. Liang, Analyst, 2013, 138, 3313.
C.V.R. Babu, N.R. Vuyyuru, K.P. Reddy, M.V. Suryanarayana, K. Mukkanti, Chirality, 2014, 26, 775.
Z. Long, C. Wang, Z. Guo, X. Zhang, L. Nordahl, X. Liang, J. Chromatogr. A, 2012, 1256, 67.
Z. Long, C. Wang, Z. Guo, X. Zhang, L. Nordahl, J. Zeng, J. Zeng, X. Liang, Analyst, 2012, 137, 1451.
Z. Long, Y. Zhang, Z. Guo, L. Wang, X. Xue, X. Zhang, S. Wang, Z. Wang, O. Civelli, X. Liang, Planta Med., 2014, 80, 1124.
Z. Long, D. Yu, Y. Liu, N. Du, Y. Tao, L. Mei, Z. Guo, X. Liang, Anal. Chim. Acta, 2015, 872, 77.
A.J. Alpert, J. Chromatogr. A, 1990, 499, 177.
V.V. Tolstikov and O. Fiehn, Anal. Biochem., 2002, 301, 298.
Y. Guo and S. Gaiki, J. Chromatogr. A, 2005, 1074, 71.
P. Hemstrom and K. Irgum, J. Sep. Sci., 2006, 29, 1784.
M. Godejohann, J. Chromatogr. A, 2007, 1156, 87.
D.V. McCalley, J. Chromatogr. A, 2007, 1171, 46.
C. Apostolou, C. Kousoulos, Y. Dotsikas, Y.L. Loukas, Biomed. Chromatogr., 2008, 22, 1393.
X. Liu and C.A. Pohl, J. Chromatogr. A, 2012, 1232, 190.
F. Al-Rimawi and U. Pyell, J. Chromatogr. A, 2007, 1160, 326.
E. Apfelthaler, W. Bicker, M. Laemmerhofer, M. Sulyok, R. Krska, W. Lindner, R. Schuhmacher, J. Chromatogr. A, 2008, 1191, 171.
X. Dong, A. Shen, Z. Gou, D. Chen, X. Liang, Carbohyd. Res., 2012, 361, 195.
M. Eckhardt, E. Langkopf, M. Mark, M. Tadayyon, L. Thomas, H. Nar, W. Pfrengle, B. Guth, R. Lotz, P. Sieger, H. Fuchs, F. Himmelsbach, J. Med. Chem., 2007, 50, 6450.
G.A. Meek, S.K.I.P. Kunhimon, R. Shankar, V.H. Dahanukar, T.K. Moha, M.B. Wagh, A.K. Pal, V.M.B. Meesala, S. Shrivastava, U.S. Patent, 2013, 20130172562 A1.
C. Wang, Z. Guo, Z. Long, X. Zhang, X. Liang, J. Chromatogr. A, 2013, 1281, 60.
C. Brunelli, T. Gorecki, Y. Zhao, P. Sandra, Anal. Chem., 2007, 79, 2472.
Z. Long, Z. Guo, I. Acworth, X. Liu, Y. Jin, X. Liu, L. Liu, L. Liang, Talanta, 2016, 151, 239.
Z. Long, Z. Guo, X. Liu, Q. Zhang, X. Liu, Y. Jin, L. Liang, H. Li, J. Wei, N. Wu, Talanta, 2016, 146, 423.
H. Luo, L. Ma, C. Paek, P.W. Carr, J. Chromatogr. A, 2008, 1202, 8.
A. Shen, Z. Guo, X. Cai, X. Xue, X. Liang, J. Chromatogr. A, 2012, 1228, 175.
C. Crafts, B. Bailey, M. Plante, I. Acworth, J. Chromatogr. Sci., 2009, 47, 534.
M. Ligor, S. Studzinska, A. Horna, B. Buszewski, Crit. Rev. Anal. Chem., 2013, 43, 64.
T. Teutenberg, J. Tuerk, M. Holzhauser, T.K. Kiffmeyer, J. Chromatogr. A, 2006, 1119, 197.
R. Agrawal, P. Jain, S.N. Dikshit, Curr. Drug Targets., 2012, 13, 970.
T. Vehovec and A. Obreza, J. Chromatogr. A, 2010, 1217, 1549.
S. Matsuyama, Y. Orihara, S. Kinugasa, H. Ohtani, Anal. Sci., 2015, 31, 61.
Acknowledgments
We thank Jiangsu Deyuan Pharmaceutical Co., Ltd for their technical assistance. We would like to acknowledge Thermo Fisher Scientific Co., Ltd. in China for research support.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Dong, S., Yan, Z., Yang, H. et al. Fast and Simple Determination of 3-Aminopiperidine without Derivatization Using High Performance Liquid Chromatography-Charged Aerosol Detector with an Ion-Exchange/Reversed-Phase Mixed-mode Column. ANAL. SCI. 33, 293–297 (2017). https://doi.org/10.2116/analsci.33.293
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.33.293