Abstract
We propose a new method for the customized design of hip exoskeletons based on the optimization of the humanmachine physical interface to improve user comfort. The approach is based on mechanisms designed to follow the natural trajectories of the human hip as the flexion angle varies during motion. The motions of the hip joint center with variation of the flexion angle were measured and the resulting trajectory was modeled. An exoskeleton mechanism capable to follow the hip center’s movement was designed to cover the full motion ranges of flexion and abduction angles, and was adopted in a lower extremity assistive exoskeleton. The resulting design can reduce human-machine interaction forces by 24.1% and 76.0% during hip flexion and abduction, respectively, leading to a more ergonomic and comfortable-to-wear exoskeleton system. The human-exoskeleton model was analyzed to further validate the decrease of the hip joint internal force during hip joint flexion or abduction by applying the resulting design.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Afoke, N.Y., Byers, P.D., Hutton, W.C., 1984. The incongruous hip joint: a loading study. Ann. Rheum. Dis., 43(2):295–301. http://dx.doi.org/10.1136/ard.43.2.295
Banala, S.K., Kim, S.H., Agrawal, S.K., et al., 2009. Robot assisted gait training with active leg exoskeleton (ALEX). IEEE Trans. Neur. Syst. Rehabil. Eng., 17(1):2–8. http://dx.doi.org/10.1109/tnsre.2008.2008280
Camomilla, V., Cereatti, A., Vannozzi, G., et al., 2006. An optimized protocol for hip joint centre determination using the functional method. J. Biomech., 39(6):1096–1106. http://dx.doi.org/10.1016/j.jbiomech.2005.02.008
Cempini, M., de Rossi, S.M.M., Lenzi, T., et al., 2013. Self-alignment mechanisms for assistive wearable robots: a kinetostatic compatibility method. IEEE Trans. Robot., 29(1):236–250. http://dx.doi.org/10.1109/TRO.2012.2226381
Esquenazi, A., Talaty, M., Packel, A., et al., 2012. The Re-Walk powered exoskeleton to restore ambulatory function to individuals with thoracic-level motor-complete spinal cord injury. Am. J. Phys. Med. Rehabil., 91(11):911–921. http://dx.doi.org/10.1097/PHM.0b013e318269d9a3
Farris, R.J., Quintero, H.A., Goldfarb, M., 2011. Preliminary evaluation of a powered lower limb orthosis to aid walking in paraplegic individuals. IEEE Trans. Neur. Syst. Rehabil. Eng., 19(6):652–659. http://dx.doi.org/10.1109/tnsre.2011.2163083
Fletcher, R., Powell, M.J., 1963. A rapidly convergent descent method for minimization. Comput. J., 6(2):163–168. http://dx.doi.org/10.1093/comjnl/6.2.163
Gamage, S.S.H.U., Lasenby, J., 2002. New least squares solutions for estimating the average centre of rotation and the axis of rotation. J. Biomech., 35(1):87–93. http://dx.doi.org/10.1016/S0021-9290(01)00160-9
Gao, B., Conrad, B.P., Zheng, N., 2007. Comparison of skin error reduction techniques for skeletal motion analysis. J. Biomech., 40(s2):S551. http://dx.doi.org/10.1016/S0021-9290(07)70541-9
Greenwald, A.S., O’Connor, J.J., 1971. The transmission of load through the human hip joint. J. Biomech., 4(6):507–528. http://dx.doi.org/10.1016/0021-9290(71)90041-8
Hidler, J., Nichols, D., Pelliccio, M., et al., 2009. Multicenter randomized clinical trial evaluating the effectiveness of the Lokomat in subacute stroke. Neurorehabil. Neur. Repair., 23(1):5–13. http://dx.doi.org/10.1177/1545968308326632
Jarrasse, N., Morel, G., 2012. Connecting a human limb to an exoskeleton. IEEE Trans. Robot., 28(3):697–709. http://dx.doi.org/10.1109/TRO.2011.2178151
Kang, M.J., 2004. Hip joint center location by fitting conchoid shape to the acetabular rim region of MR images. Proc. 26th Annual Int. Conf. of the IEEE. p.4477–4480. http://dx.doi.org/10.1109/iembs.2004.1404244
Kawamoto, H., Sankai, Y., 2005. Power assist method based on phase sequence and muscle force condition for HAL. Adv. Robot., 19(7):717–734. http://dx.doi.org/10.1163/1568553054455103
Krupicka, R., Szabo, Z., Viteckova, S., et al., 2014. Motion capture system for finger movement measurement in parkinson disease. Radioengineering, 23(2):659–664.
Leardini, A., Cappozzo, A., Catani, F., et al., 1999. Validation of a functional method for the estimation of hip joint centre location. J. Biomech., 32(1):99–103. http://dx.doi.org/10.1016/S0021-9290(98)00148-1
Lee, K.M., Guo, J., 2010. Kinematic and dynamic analysis of an anatomically based knee joint. J. Biomech., 43(7):1231–1236. http://dx.doi.org/10.1016/j.jbiomech.2010.02.001
Lenzi, T., Vitiello, N., de Rossi, S.M.M., et al., 2011. Measuring human–robot interaction on wearable robots: a distributed approach. Mechatronics, 21(6):1123–1131. http://dx.doi.org/10.1016/j.mechatronics.2011.04.003
Menschik, F., 1997. The hip joint as a conchoid shape. J. Biomech., 30(9):971–973. http://dx.doi.org/10.1016/S0021-9290(97)00051-1
Nef, T., Riener, R., Müri, R., et al., 2013. Comfort of two shoulder actuation mechanisms for arm therapy exoskeletons: a comparative study in healthy subjects. Med. Biol. Eng. Comput., 51(7):781–789. http://dx.doi.org/10.1007/s11517-013-1047-4
Ren, Y.P., Kang, S.H., Park, H.S., et al., 2013. Developing a multi-joint upper limb exoskeleton robot for diagnosis, therapy, and outcome evaluation in neurorehabilitation. IEEE Trans. Neur. Syst. Rehabil. Eng., 21(3):490–499. http://dx.doi.org/10.1109/tnsre.2012.2225073
Schiele, A., van der Helm, F.C.T., 2006. Kinematic design to improve ergonomics in human machine interaction. IEEE Trans. Neur. Syst. Rehabil. Eng., 14(4):456–469. http://dx.doi.org/10.1109/TNSRE.2006.881565
Stienen, A.H.A., Hekman, E.E.G., van der Helm, F.C.T., et al., 2009. Self-aligning exoskeleton axes through decoupling of joint rotations and translations. IEEE Trans. Robot., 25(3):628–633. http://dx.doi.org/10.1109/TRO.2009.2019147
Suzuki, K., Mito, G., Kawamoto, H., et al., 2007. Intention-based walking support for paraplegia patients with Robot Suit HAL. Adv. Robot., 21(12):1441–1469.
Valiente, A., 2005. Design of a Quasi-Passive Parallel Leg Exoskeleton to Augment Load Carrying for Walking. MS Thesis, Massachusetts Institute of Technology, Boston, USA.
Veneman, J.F., Ekkelenkamp, R., Kruidhof, R., et al., 2006. A series elastic- and bowden-cable-based actuation system for use as torque actuator in exoskeleton-type robots. Int. J. Robot. Res., 25(3):261–281. http://dx.doi.org/10.1177/0278364906063829
Wang, D., Lee, K.M., Guo, J., et al., 2014. Adaptive knee joint exoskeleton based on biological geometries. IEEE/ASME Trans. Mech., 19(4):1268–1278. http://dx.doi.org/10.1109/TMECH.2013.2278207
Wu, G., Siegler, S., Allard, P., et al., 2002. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine. J. Biomech., 35(4):543–548. http://dx.doi.org/10.1016/S0021-9290(01)00222-6
Yan, H., Yang, C., Zhang, Y., et al., 2014. Design and validation of a compatible 3-degrees of freedom shoulder exoskeleton with an adaptive center of rotation. J. Mech. Des., 136(7):071006. http://dx.doi.org/10.1115/1.4027284
Zakani, S., Smith, E.J., Kunz, M., et al., 2012. Tracking translations in the human hip. ASME Int. Mechanical Engineering Congress and Exposition, p.109–115. http://dx.doi.org/10.1115/IMECE2012-87882
Zoss, A.B., Kazerooni, H., Chu, A., 2006. Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX). IEEE/ASME Trans. Mech., 11(2):128–138. http://dx.doi.org/10.1109/TMECH.2006.871087
Author information
Authors and Affiliations
Corresponding author
Additional information
Project supported by the National Natural Science Foundation of China (No. 51221004)
ORCID: Can-jun YANG, http://orcid.org/0000-0002-3712-0538
Rights and permissions
About this article
Cite this article
Yang, W., Yang, Cj. & Xu, T. Human hip joint center analysis for biomechanical design of a hip joint exoskeleton. Frontiers Inf Technol Electronic Eng 17, 792–802 (2016). https://doi.org/10.1631/FITEE.1500286
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1631/FITEE.1500286