Abstract
A two-channel nutation magnetometer on the basis of the nuclear-magnetic resonance (NMR) is described. It allows measurements of the magnetic-field induction within a range of 0.06–8.29 mT with an inhomogeneity of ≥10–2 cm–1 in different compartments of a sea ship. The distance from the location of a device that records NMR signals to the point at which the magnetic induction is determined ranges from 1 to 69 m. The measurement error is 0.3% and the sensitivity is 10–11 Т/Hz1/2.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Dudkin, V.I. and Pakhomov, L.N., Kvantovaya elektronika (Quantum Electronics), St. Petersburg: Politekhn. Univ., 2012.
Davydov, V.V., Velichko, E.N., Dudkin, V.I., and Karseev, A.Yu., Metrologiya, 2014, no. 5, p. 32.
Gordnev, I.I. and Sergeichuk, K.Ya., Ekranirovanie apparatury i kabelei (Screening of Cables and Equipment), Moscow: Radio Svyaz’, 1990.
Davydov, V.V., Dudkin, V.I., and Karseev, A.Yu., Opt. Mem. Neural Networks (Inform. Optics), 2014. vol. 23, p. 170.
Vinogradov, E.M., Vinokurov, V.I., and Kharchenko, I.P., Elektromagnitnaya sovmestimost’ radioelektronnykh sredstv (Electromagnetic Compatibility of Radioelectronic Devices), Leningrad: Sudostroenie, 1992.
Aleksandrov, E.B. and Vershovskii, A.K., Phys.-Usp., 2009, vol. 52, p. 73.
Aleksandrov, E.B., Phys.-Usp., 2001, vol. 44, p. 1199.
Zvezhinskii, S.S. and Parfentsev, I.V., Spetstekhnika Svyaz’, 2009, no. 3, p. 18.
Davydov, V.V., Dudkin, V.I., and Karseev, A.Yu., Tech. Phys. Lett., 2014. vol. 40, p. 845.
Aleksandrov, E.B., Phys.-Usp., 2010, vol. 53, p. 487.
Vershovskii, A.K., Dmitriev, S.P., and Pazgaev, A.S., Tech. Phys., 2013, vol. 58, p. 1481.
Davydov, V.V. and Semenov, V.V., Instrum. Exp. Tech., 1999, vol. 42, no. 3, p. 427.
Pryakhin, A.E., Shushkevich, S.S., and Orobei, I.O., Instrum. Exp. Tech., 1983, no. 6, p. 1456.
GOST (State Standard) 8.095-73: State Primary Etalon and All-Union Calibration Scheme for Magnetoinduction Measurement Means.
GOST (State Standard) 8.144-75: State Special Etalon and All-Union Calibration Scheme for Magnetoinduction Measurement Means in the 0.05–2 T Range.
Yagola, G.K., Kazantsev, Yu.I., Simonov, V.M., and Cheburkov, D.I., Izmerit. Tekhnika, 1976, no. 3, p. 52.
Yudin, A.V., Prib. Tekh. Eksp., 1967, no. 6, p. 188.
Pryakhin, A.E., Shushkevich, S.S., Orobei, I.O., Lavrinovich, E.A., Bezuglyi, A.I., and Faibyshev, A.E., Prib. Tekh. Eksp., 1986, no. 6, p. 216.
Davydov, V.V., Izv. Vyssh. Uchebn. Zaved., Priborostr., 2001, vol. 44, no. 8, p. 49.
Davydov, V.V., Dudkin, V.I., and Karseev, A.Yu., Izv. Vyssh. Uchebn. Zaved., Priborostr., 2014. vol. 57, no. 3, p. 44.
Davydov, V.V. and Karseev, A.Yu., Peterb. Zh. Elektron., 2014. no. 1, p. 89.
Kozin, V.P. and Tolstoi, A.E., Prib. Tekh. Eksp., 1969, no. 1, p. 165.
Davydov, V.V., Dudkin, V.I., and Karseev, A.Yu., Izv. Vyssh. Uchebn. Zaved., Priborostr., 2013. vol. 56, no. 10, p. 64.
Davydov, V.V., Dudkin, V.I., and Karseev, A.Yu., Izmer. Tekh., 2014. no. 8, p. 44.
Abragam, A., Yadernyi magnetizm (Nuclear Magnetism), Moscow: Inostrannaya Literatura, 1963.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © V.V. Davydov, V.I. Dudkin, A.Yu. Karseev, 2015, published in Pribory i Tekhnika Eksperimenta, 2015, No. 6, pp. 84–90.
Rights and permissions
About this article
Cite this article
Davydov, V.V., Dudkin, V.I. & Karseev, A.Y. A two-channel nutation nuclear-magnetic magnetometer for remote control of the magnetic-field induction. Instrum Exp Tech 58, 787–793 (2015). https://doi.org/10.1134/S0020441215060056
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441215060056