Abstract
Motile cilia in the mammalian oviduct play a key role in reproduction, such as transporting fertilized oocytes to the uterus for implantation. Due to their small size (~5–10 μm in length and ~300 nm in diameter), live visualization of cilia and their activity in the lumen of the oviduct through tissue layers represents a major challenge not yet overcome. Here, we report a functional low-coherence optical imaging technique that allows in vivo depth-resolved mapping of the cilia location and cilia beat frequency (CBF) in the intact mouse oviduct with micro-scale spatial resolution. We validate our approach with widely-used microscopic imaging methods, present the first in vivo mapping of the oviduct CBF in its native context and demonstrate the ability of this approach to differentiate CBF in different locations of the oviduct at different post-conception stages. This technique opens a range of opportunities for live studies in reproductive medicine as well as other areas focused on cilia activity and related ciliopathies.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Introduction
Cilia are microtubule-based organelles located on the surface of a variety of epithelial cells. Motile cilia are present in the organs in the body including oviduct, lungs, brain and airway and act to propel fluid or mucus1,2. The mechanisms of cilia motility are complex and have not been fully understood3,4,5, though its associated abnormalities, such as primary ciliary dyskinesia, often result in a wide range of diseases6,7. The mammalian oviduct is one of the organs that rely heavily on the motility of cilia for its normal functions. The inner lumen of the oviduct is covered with ciliated epithelial cells8. With the size of ~5–10 μm in length and ~300 nm in diameter, the oviduct cilia beat periodically to support the mammalian reproduction, such as regulating spermatozoa in the fertilization process8,9,10. The transport of fertilized oocytes to the uterus for implantation is facilitated by the cilia as well as by muscular contractions in the oviduct wall8,9,10. The cilia beat frequency (CBF) is widely used as a fundamental measure of the cilia activity for studying its role in the reproductive process11,12,13,14,15,16.
Bright-field microscopy and confocal microscopy are two major imaging techniques that have been extensively applied for in vitro visualization of cilia and assessment of CBF11,12,13,14,15,16,17,18,19,20. Relying on the brightness change caused by the beat of cilia, bright-field microscopy generally does not require exogenous contrast agents. The imaging depth required to cover the cross-section of the intact mouse oviduct tube is over 800 μm (larger for other mammalian models and humans). Because of the limited imaging depths of these two methods, during experiments, the oviduct has to be dissected from the body and opened up to expose the ciliated lumen for direct imaging. This might significantly alter the biochemical and biomechanical environment of the cilia and thus lead to inaccurate interpretation of the physiological process4,21. Detecting periodical variations in the backscattered laser light to measure the CBF have also been previously reported22,23,24. Although in vivo application in human fallopian tube has been achieved through an endoscopic fiber optic probe25, the approach is limited to a single point integrated measurement, which is lacking both lateral and in-depth information.
Optical coherence tomography (OCT) is a noninvasive depth-resolved 3D imaging modality that provides micro-scale spatial resolution with the imaging depth of 1–2 mm in highly-scattering tissues26,27,28. Recent developments of OCT-based methods for the imaging of cilia dynamics have been focused on the respiratory tract29,30,31,32. With micro-OCT (μOCT) that provides 1-micron spatial resolution33, Liu, et al. successfully imaged and visualized the phases of the ciliary stroke pattern from human bronchial epithelial culture and ex vivo swine trachea, thus directly obtaining the frequency of cilia beat30. While the size of cilia is below the resolution limit of traditional OCT imaging and the cilia cannot be directly visualized, Oldenburg, et al. employed the variations of the speckles produced by the movement of cilia to define the cilia location and measure the CBF29. The imaging of the cilia location was conducted on the in vitro model of airway epithelium with the mapping of the standard deviation of the speckle change from different frequency bands and the CBF measurement was demonstrated on the ex vivo and in vitro mouse trachea samples29. Focusing on the cilia-driven fluid flow, Jonas, et al. and Huang, et al. developed OCT-based particle tracking velocimetry to image the quantitative flow dynamics induced by the cilia on Xenopus embryonic model34,35, which indirectly probes the ciliary function. These studies established the feasibility of using OCT for functional cilia imaging. However, quantitative micro-scale mapping of both cilia location and CBF over a large field of view has not been previously demonstrated. Besides, in all these studies the ciliated surface was directly exposed for imaging.
In this work, we combined live mouse manipulation approach with the further development of the OCT-based speckle-variance cilia-detection method29 to introduce a tomographic imaging technique capable of mapping both the cilia location and the CBF in the intact mouse oviduct in vivo with micro-scale spatial resolution and depth-resolved field of view that covers the whole depth of the oviduct. Since the method takes advantage of the speckles produced by the interference of light36, no exogenous contrast agents are required. As a novel form of functional OCT (fOCT)37,38,39, we utilize both the amplitude and the frequency position of the major peak from the ciliary motion spectrum and reconstruct, for the first time, high-resolution mapping of both cilia location and CBF through tissue layers in vivo. We validate the approach using histological immunofluorescence microscopy for the cilia-location mapping and using bright-field microscopy for the CBF mapping. With this method, we present the first in vivo application of the oviduct CBF mapping in relation to the post-conception stages and the anatomical locations. Our results indicate that described fOCT approach can be successfully applied to study the dynamic ciliary behavior in mouse oviduct in vivo, opening the door for a variety of live studies of mammalian reproduction and infertility, as well as other research areas involving the analysis of cilia activity.
Results
Description of in vivo fOCT approach
Our fOCT imaging technique is based on a spectral domain OCT system (Fig. 1a) which consists of a near-infrared broad-band laser source, a fiber-based Michaelson interferometer and a high-resolution spectrometer40. For fOCT data acquisition, the OCT system was set to acquire a time sequence of B-scans at each 3D frame location to capture the dynamics of speckles. The frame rate was set to be 100 Hz with 1024 frames acquired for each position. According to the Nyquist-Shannon sampling theorem, the maximum measurable frequency with these settings is 50 Hz, which, based on the previously-reported values of below 25 Hz, is sufficient to resolve the CBF in mammalian oviduct12,13,14,15,41,42. Also, the resulted spectral resolution is ~0.1 Hz for the frequency measurement and the time required for the fOCT imaging of each frame location with these settings is 10.24 seconds.
For the imaging of the mouse oviduct in vivo, a small incision (~1 cm long) was made parallel to the dorsal midline on one side of the anesthetized female. The reproductive organs (the ovary, oviduct and a part of the uterine horn) were gently pulled out through the incision with a forceps and stabilized with a vessel clamp for imaging (Fig. 1a). The experimental stabilization approach (detailed in the Methods section) helps to prevent the tissue motions associated with animal breathing and heartbeat. Similar procedures for exposing reproductive organs are routinely used to transfer zygotes in the production of transgenic mice43; these procedures do not compromise animal survival and are not associated with reproductive complications. Figure 1b shows a microscope image of the exposed reproductive organs. For comparison, Fig. 1c contains a 3D OCT structural image in which distinct morphological features of the oviduct are clearly evident and can be used to locate the positions for the mapping of cilia location and CBF.
Method for mapping cilia location and CBF with fOCT
The CBF mapping was obtained through spectral analysis of the speckle variation in the continuously recorded B-scan OCT structural images (Fig. 2a). From the recorded image series, 3D matrices with the transverse, depthwise and temporal dimensions were obtained and the OCT intensities (speckles) over time were analyzed for each spatial pixel. Cilia in the mouse oviduct generally have a length of around 5 μm44 and thus the beat of the cilia results in the movement of the scatter (the top part of the cilia) in the scale below the spatial resolution of the OCT system. This type of optical path-length change places the interference of light at different states (e.g. constructive and destructive interference)45, which produces variations of the OCT intensity over time at the spatial locations corresponding to cilia (Fig. 2b). Since the beat of cilia in the oviduct is periodic13, fast Fourier transform was performed to the temporal intensity profile to obtain the amplitude spectrum of the cilia beat (Fig. 2b). In parallel, a binary mask (Fig. 2c) was produced from the averaged B-scan OCT images over time to eliminate the background and highlight the oviduct tissue. The amplitude spectra from all spatial pixels associated with the oviduct tissue were then plotted together to determine the thresholds for the amplitude and frequency in the spectral domain. Because we do not expect CBF to exceed 25 Hz12,13,14,15,41,42, all signals at the frequency window of 25–30 Hz were taken as noise and were used to set the amplitude threshold for the whole frequency range. All the frequency peaks (except for the zero-frequency components) above this threshold were considered as the CBF signal. The frequency thresholds were set according to the lowest and the highest peak positions (except for the zero-frequency components) in the amplitude spectra. Thus, the peak amplitudes from the frequency spectra were mapped to the structural image of the oviduct, revealing the location of the cilia distributed on the inner lumen (Fig. 2d). The lack of similar periodic motion in the other parts of the oviduct tissue, such as the mucosa, creates the contrast for imaging the cilia location. For the mapping of the CBF, the frequency position of the peak in the amplitude spectrum (Fig. 2e) was obtained for each spatial position of the cilia according to the binary mask (Fig. 2f) produced from the cilia location image. Consequently, the image of CBF mapped to the 2D depth-resolved oviduct structure was generated (Fig. 2g) as the visual representation of the cilia dynamics. For functional imaging in 3D, the generated 2D fOCT images from all the frame locations can be put together to form the 3D map of cilia location and CBF, where tomographic sections from all directions can be easily visualized and analyzed.
Validation of fOCT mapping of cilia location
To validate our fOCT findings, we compared the mapping of cilia locations using fOCT with confocal fluorescence microscopy of immunostained oviduct sections. The oviduct of a mouse at 0.5 days post-conception (dpc) was imaged in vivo with fOCT. Three locations were selected along the oviduct for the analysis: the anterior ampulla close to the osteum, the posterior ampulla close to isthmus and the isthmus (Fig. 3a). Right after the fOCT imaging, the oviduct tissue was carefully dissected out and prepared for immunostaining. The mapping results from both fOCT and immunostaining clearly showed the decrease of the cilia coverage in the ampulla from the osteum side to the isthmus side (Fig. 3b,c) with isthmus having much fewer cilia than the ampulla (Fig. 3d). These findings correlate with previous in vitro observations in the human46 and mouse oviduct47. The distribution of the cilia in the lumen of the oviduct obtained by fOCT is in good agreement with the corresponding histological immunostaining (Fig. 3b,c), which is a widely-used standard cilia analysis method17,18,19. Quantitative analysis shows similar percentage of the cilia coverage of oviduct lumen obtained from fOCT and immunofluorescence histological analysis (see Supplementary Figure S1). These results confirm that the described fOCT approach allows for efficient mapping of the cilia location in the mouse oviduct in vivo.
Validation of fOCT mapping of CBF
To validate the acquired CBF measurements, we performed fOCT analysis as well as bright-field microscopy on an in vitro explanted oviduct tissue that was cut and opened up to expose the luminal surface in 1x phosphate buffered saline (PBS) at room temperature. The oviduct was first imaged using bright-field microscopy with a digital camera, a traditional imaging method that has been extensively utilized in the studies of CBF in the mammalian oviduct11,12,13,14,15,41,42. From the wide-field microscopic image (Fig. 4a), we focused on a typical region of a mucosa fold (Fig. 4b) and performed continuous 2D image recording with a frame rate of 51 Hz, which enables direct visualization of the cilia beat along the fold. Similar to standard CBF analyzing methods based on the intensity of the microscopic image13,14,15,16,17,25,26, fast Fourier transform with the spectral resolution of ~0.05 Hz was performed on each pixel of the image followed by mapping of the peak amplitude from the frequency spectrum, generating an image of the cilia locations (Fig. 4c). The frequency positions of the peaks in the spectrum were then mapped to the locations of cilia, providing the map of CBF (Fig. 4d,e). Right after imaging with the bright-field microscope, the same oviduct tissue was immediately transferred to the OCT imaging stage. A 3D OCT structural image (Fig. 4f) was first taken to identify the region of interest (Fig. 4g) matching the one from the optical microscope. Then fOCT imaging and analysis was performed in 3D that covers the target region, showing the cilia locations and the CBF mapped to the 3D oviduct structural image (Fig. 4h,i,j). A comparison of the 3D fOCT results with the CBF mapping from the bright-field microscope demonstrated that the frequency values obtained from these two techniques were similar. Images acquired with fOCT in Fig. 4h–j belong to the en face view of the 3D visualization over the whole imaging depth and, therefore, reveal larger ciliated areas, in contrast to the bright-field images in Fig. 4c–e, which show visualization of cilia only in a single focal plane of ~9 μm in thickness. The statistics of the CBF (Fig. 4k) measured with these two imaging techniques from the fields of view shown in Fig. 4d,i indicated no significant difference with a p value of 0.28 from a two-sample two-tailed student’s t test. This result further demonstrated that the fOCT technique is able to measure the CBF with the accuracy comparable to the widely-used in vitro approach. The tomographic cross-sectional image (Fig. 4l,m) selected from the fOCT 3D volume showed good agreement with the results from the bright-field microscopy, demonstrating the feasibility of mapping CBF using fOCT. It is important to note that the overall CBF measured in vitro with the oviduct dissected out and the ciliated surface exposed for imaging appears to be lower compared with the in vivo experiments (described below). Such difference can be explained by the effects of lower temperature, difference in local microenvironment and interruption in the nutrient delivery, all of which could affect cilia dynamics21,48,49.
In vivo fOCT imaging and studies of ciliary activity
We next tested the feasibility of the described approach for in vivo investigations of the cilia activities in the mouse oviduct at different locations of the oviduct through different post-conception stages. Comparative fOCT analysis in the ampulla (Fig. 5a) and the isthmus (Fig. 5b) revealed similar CBF ranges. It is interesting to note that cilia are organized in patches of different sizes and the cilia from neighboring areas beat at distinct frequencies. A similar phenomenon has previously been observed in vitro13. Based on five mice used in this study, no significant difference has been detected (p values larger than 0.05) between the CBF from the ampulla and the isthmus of the same oviduct (Fig. 5c), suggesting that the cilia beats from these two different anatomical locations are likely to have the same CBF range. Such findings correlate with the in vitro experimental results of the CBF in the human fallopian tube41. We also performed comparative fOCT analysis on the posterior ampulla of the oviduct (close to the isthmus) at the days of 0.5 and 2.5 post-conception. Our measurements revealed that the frequency range of the cilia beat in the ampulla at 0.5 dpc (Fig. 5d,e,f) is higher than that at 2.5 dpc (Fig. 5g,h,i) with p = 0.027, less than 0.05 (alpha value) from a two-sample two-tailed student’s t test. The average CBF value over the imaging field of view from individual mouse was averaged (Fig. 5j) and corresponds to 8.4 ± 1.6 Hz at 0.5 dpc and 3.9 ± 1.7 Hz at 2.5 dpc (mean ± standard deviation). These results indicate that the described fOCT approach allows measuring a range of physiological CBFs and differentiating the frequencies at different post-conception stages in the mouse oviduct in vivo.
Discussion
We present and validate an approach for live mapping of cilia and their dynamics in the intact mouse oviduct. In vivo capability and the large depth of view (covering the whole cross-section of the mouse oviduct tube) are two major advantages of the described approach over the existing widely-used microscopic methods that require opening up of the dissected oviduct and exposing the ciliated surface for imaging. In addition, unlike fluorescence imaging methods, fOCT relies on the natural optical contrast of tissues and does not require any exogenous contrast agents or vital reporters, which could possibly affect ciliary function and motility50. These important features of fOCT make it a unique research tool that opens the door for a number of in vivo studies in reproductive medicine and cilia biology in general.
The measurable frequency range of fOCT is determined by the sampling frequency of the OCT system. In the presented study, we applied a 100 Hz frame rate, resulting in 50 Hz of the highest detectable frequency, sufficient for the measurement of CBF in the mammalian oviduct12,13,14,15,41,42. Wider dynamic range is possible with faster acquisition of the B-scan OCT images. However, this generates larger data sets and complicates data storage and analysis. Based on a fixed frame rate, the pixel resolution in the frequency domain is dependent on the time duration of recording of the dynamic activity. With 10.24 seconds, we have obtained spectral resolution close to 0.1 Hz in our CBF measurement. Longer data acquisition for each frame location will result in smaller pixel size in the frequency domain. These settings could be optimized for different purposes during the fOCT imaging, such as minimizing the imaging time or improving the frequency resolvability. In terms of the spatial scale for the CBF mapping, we obtained ~2 μm in both the axial and the transverse directions with a depth of view able to cover the ampulla of the mouse oviduct. Employing an ultrahigh-resolution OCT system and increasing scanning positions during the fOCT imaging can further improve the spatial scale.
Our studies revealed lower CBF in the oviduct at 2.5 dpc in comparison to 0.5 dpc (Fig. 5j). While ciliary dynamics in the oviduct through preimplantation stages are not well characterized, the difference in CBF at different stages is not unexpected. It takes about four days for the oocyte to travel through the length of the oviduct, as it undergoes fertilization, transitions to zygote and undertakes first divisions. These dramatic transitions during the transport of the embryo through different compartments of the oviduct are associated with changes in hormonal levels, some of which can have an effect on cilia dynamics12,42. Sperm also have an effect on cilia dynamics14. At about 0.5 dpc, the motile sperm are present in the ampulla51, while at 2.5 dpc the sperm lose their motility52. Previous in vitro studies show that the presence of motile sperm in rat oviduct increases the CBF through adrenomedullin (ADM) hormone, which causes CBF increase14. Thus, the detected higher CBF of the ampulla at 0.5 dpc might be triggered by the presence of the motile sperm, which are losing their motility and getting cleared at 2.5 dpc. This question can be further investigated using the described in vivo fOCT approach in correlation with the analysis of hormonal levels. Comparative analysis of CBF in plugged and unplugged animals might provide an insight into in vivo regulation of the cilia dynamics by sperm.
Previous work has demonstrated that structural OCT imaging could be used to characterize microfluidic-scale flow generated by the motile cilia from the epithelium of Xenopus tropicalis embryos through tracking of introduced polystyrene microspheres34,35, which reveals the function of the cilia in an indirect way. This particle tracking velocimetry approach can potentially be combined with our fOCT technique in the mouse oviduct to study the transport of the oocytes and the cumulus cells through the oviduct in correlation with cilia function in vivo, investigate the fluid dynamics and further understand the interplay between cilia function and biomechanical environment.
Potentially this imaging technique could be utilized in longitudinal studies of the development of mouse oviduct and ciliary functions. In the production of transgenic mice, mouse reproductive organs are routinely exposed by surgical manipulations for transferring zygotes43, which is not associated with any reproductive consequences. As our in vivo fOCT approach follows this procedure, we do not expect any detrimental effect from the imaging process. However, for prolonged imaging sessions, measures should be taken to prevent tissue dehydration and control the environmental conditions. Additional optimization procedures might be necessary to improve the consistency of the measurements and the tissue preservation depending on the purpose of the experiments.
Currently the role of cilia in fertility has not been well characterized and the cilia dynamics in relation to fertilization and oocytes transport remain unclear53, largely due to the lack of powerful in vivo imaging tools. The described fOCT approach for in vivo CBF mapping might provide spatially-resolved information of cilia dynamics through estrous cycle and gestational stages. In correlation with structural analysis, oocyte tracking and molecular genetic analysis of pathways implemented in fertility, this approach can contribute to screening of pharmacological agents affecting motility and understanding of a variety of questions in reproductive biology.
Because the motile characteristic of the cilia is essential for various biological processes in the mammalian body6, applications of the reported fOCT are not limited to the assessment of oviduct ciliary function. For example, the motility of cilia at the ventral surface of the embryonal node in mammals generates flow that is necessary for initiating the signaling cascade for left-right patterning during development54. Since OCT has been successfully applied for live imaging of post-implantation mouse embryos55, the fOCT method could be directly implemented to provide advanced phenotyping for related research in developmental biology. In addition, the integration of this fOCT CBF mapping approach with the endoscopic probe56 could lead to in vivo simultaneous depth-resolved functional and structural assessment of ciliated epithelial surfaces in the body, such as the human fallopian tube and respiratory tract. Therefore, the fOCT technique introduced in this paper has potentially broad applications in cilia-related biological studies and clinical diagnosis.
Methods
Optical coherence tomography system
We utilized a home-built spectral domain optical coherence tomography (OCT) system with a Titanium:Sapphire laser (Micra-5, Coherent, Inc) providing low-coherence light with the bandwidth of ~110 nm centered at ~808 nm. The collimated laser beam is coupled into a fiber-based interferometer with a neutral density filter to control the light intensity. The interference of the light from the reference and the sample arms is spatially separated in terms of the wavelength and focused onto a high-speed line scan CMOS camera (spL4096-140 km, Basler, Inc) with the spectral resolution of ~0.029 nm. With fast-Fourier transform of the equal k-space fringes, the 4096 pixels of the camera enables 2048 spatial resolving points of A-scan for the imaging depth of ~5.6 mm available in air. Two galvanometer-mirrors were used to obtain the transverse scanning of the laser beam across the sample. The control and synchronization of the mirror movement is realized with signals generated from the computer. The OCT system provides an axial resolution of ~5 μm in tissue with the imaging beam diameter of ~4 μm at the focal plane.
Immunohistochemistry and fluorescence imaging
After dissection, the oviduct tissue was embedded in optimal cutting temperature compound and immediately transferred to −30 °C storage. The frozen volume was sectioned at ~10 μm and fixed in 4% methanol-free paraformaldehyde in phosphate-buffered saline (PBS). The sections were first washed with PBS (5 minutes) three times and then permeabilized with PBS containing 0.1% Triton X-100 (10 minutes) repeated three times at room temperature (RT). After this, PBS was used again to wash the sections (5 minutes) three times. The sections were then incubated at RT with 5% bovine serum albumin (BSA) in PBS for at least one hour. After this, tissue sections were incubated with the primary antibody anti-beta tubulin (1:400 dilution) in PBS containing 5% BSA overnight at 4 °C. Sections were then washed with PBS (5 minutes) three times. After this, sections were incubated with the secondary antibody DyLight 488 conjugated rabbit IgG (H&L) (1:400 dilution), CF594 conjugated phalloidin (1:80 dilution) and diamidino-2-phenylindole (DAPI; 1:100 dilution) in PBS containing 5% BSA for at least one hour at RT. Sections were then washed (5 minutes) three times, mounted and covered with micro cover glasses. The processed specimens were kept at 4 °C. Here, the rabbit IgG (H&L) antibody is used to label the anti-beta tubulin antibody that targets the microtubules of the cilia, the phalloidin reacts with F-actin and labels the cytoskeleton of the cells and the DAPI stains the nucleus of the cells. The anti-beta tubulin antibody is purchased from Abcam plc. (ab6046). The rabbit IgG (H&L) secondary antibody with DyLight 488 conjugated is purchased from Rockland Immunochemicals Inc. (611-741-127). The CF594 conjugated phalloidin is purchased from Biotium Inc. (00045-300U).
Imaging of the stained oviduct sections was conducted using a confocal laser scanning microscope (Zeiss LSM 780) with a 20x plan-apochromatic dry objective (0.8 NA). Both solid-state and Argon lasers were utilized for the fluorescence imaging, which provide 561 nm light for the excitation of CF594, 488 nm for the excitation of DyLight 488 and 405 nm for the excitation of DAPI. The corresponding filters of these three channels select the wavelength ranges of 579–685 nm (CF594), 499–570 nm (DyLigh 488) and 410–495 nm (DAPI) for visualization. The diameter of the pinhole was set to be 27 μm for each channel.
Bright-field microscopic imaging
Bright-field microscopic imaging of the in vitro oviduct was performed using a Zeiss Axio Zoom. V16 microscope equipped with a digital camera (AxioCam HRm). The time series of the bright-field microscopic images from the oviduct were taken with 180x magnification at a frame rate of 51 Hz. The acquired 2D images have the pixel scale of 1.15 μm for both transverse directions. The depth of field provided by the microscope is ~9 μm.
Mouse manipulation
The wild type CD-1 male and female mice were paired to establish timed mattings overnight as determined by the presence of a vaginal plug. The presence of the plug in the day is designated as 0.5 days post-conception (dpc). At 0.5 dpc or 2.5 dpc, mice were anesthetized by intraperitoneal injection with a 1.25% Avertin solution and placed on a heating pad at 37 °C to maintain body temperature. Hair removal cream was used to expose the dorsal lateral skin. The depilated skin was treated with 70% ethanol and a small incision (~1 cm) was made parallel to the dorsal midline. A blunt forceps was used on the ovarian fat pad to gently pull the ovary/oviduct/uterus out of the body. A vessel clamp was utilized to hold the fat pad to keep the exposed tissues stable for imaging. The vessel clamp was fixed onto a stabilized optical breadboard, which helped to avoid motion artifacts due to breathing and heartbeat. Adjustments of the whole tissue structure with forceps were performed under dissection microscope to orient the oviduct facing up for imaging with the OCT system. The whole process is conducted at room temperature. The animals were sacrificed after the imaging and the oviducts were collected for subsequent histological analysis. All animal manipulation procedures described here were approved by the Animal Care and Use Committee of the Baylor College of Medicine. All experiments were carried out in accordance with the approved guidelines and regulations.
Software
For fOCT imaging, the OCT system control and data acquisition were through LabVIEW (National Instruments Corporation). For bright-field imaging and confocal imaging, ZEN software provided by Zeiss was used to capture the images. The data processing described in the paper was performed using Matlab (MathWorks, Inc.). Imaris software (Bitplane) was used for image registration and 3D rendering.
Additional Information
How to cite this article: Wang, S. et al. In vivo micro-scale tomography of ciliary behavior in the mammalian oviduct. Sci. Rep. 5, 13216; doi: 10.1038/srep13216 (2015).
References
Salathe, M. Regulation of mammalian ciliary beating. Annu. Rev. Physiol. 69, 401–422 (2007).
Jain, R. et al. Sensory functions of motile cilia and implication for bronchiectasis. Front. Biosci. ( Schol. Ed.) 4, 1088–1098 (2012).
Wirschell, M. et al. Regulation of ciliary motility: Conserved protein kinases and phosphatases are targeted and anchored in the ciliary axoneme. Arch. Biochem. Biophys. 510, 93–100 (2011).
Elgeti, J. & Gompper, G. Emergence of metachronal waves in cilia arrays. Proc. Natl. Acad. Sci. USA 110, 4470–4475 (2013).
Onoufriadis, A. et al. Targeted NGS gene panel identifies mutations in RSPH1 causing primary ciliary dyskinesia and a common mechanism for ciliary central pair agenesis due to radial spoke defects. Hum. Mol. Genet. 23, 3362–3374 (2014).
Ibañez-Tallon, I., Heintz, N. & Omran, H. To beat or not to beat: roles of cilia in development and disease. Hum. Mol. Genet. 12, R27–R35 (2003).
Leigh, M. W. et al. Clinical and genetic aspects of primary ciliary dyskinesia/Kartagener syndrome. Genet. Med. 11, 473–487 (2009).
Lyons, R. A., Saridogan, E. & Djahanbakhch, O. The reproductive significance of human Fallopian tube cilia. Hum. Reprod. Update 12, 363–372 (2006).
Coy, P., García-Vázquez, F. A., Visconti, P. E. & Avilés, M. Roles of the oviduct in mammalian fertilization. Reproduction 144, 649–660 (2012).
Halbert, S., Tam, P. & Blandau, R. Egg transport in the rabbit oviduct: the roles of cilia and muscle. Science 191, 1052–1053 (1976).
Noreikat, K., Wolff, M., Kummer, W. & Kölle, S. Ciliary Activity in the Oviduct of Cycling, Pregnant and Muscarinic Receptor Knockout Mice. Biol. Reprod. 86, 120 (2012).
Bylander, A. et al. Rapid effects of progesterone on ciliary beat frequency in the mouse fallopian tube. Reprod. Biol. Endocrinol. 8, 48 (2010).
Shi, D., Komatsu, K., Uemura, T. & Fujimori, T. Analysis of ciliary beat frequency and ovum transport ability in the mouse oviduct. Genes Cells 16, 282–290 (2011).
Liao, S. B., Ho, J. C., Tang, F. & O, W. S. Adrenomedullin increases ciliary beat frequency and decreases muscular contraction in the rat oviduct. Reproduction 141, 367–372 (2011).
Zhao, W. et al. Levonorgestrel decreased cilia beat frequency of human fallopian tubes and rat oviducts without changing the morphological structure. Clin. Exp. Pharmacol. Physiol. 42, 171–178 (2015).
Knoll, M., Shaoulian, R., Magers, T. & Talbot, P. Ciliary beat frequency of hamster oviducts is decreased in vitro by exposure to solutions of mainstream and sidestream cigarette smoke. Biol. Reprod. 53, 29–37 (1995).
Enuka, Y., Hanukoglu, I., Edelheit, O., Vaknine, H. & Hanukoglu, A. Epithelial sodium channels (ENaC) are uniformly distributed on motile cilia in the oviduct and the respiratory airways. Histochem. Cell Biol. 137, 339–353 (2012).
Teilmann, S. C. et al. Localization of transient receptor potential ion channels in primary and motile cilia of the female murine reproductive organs. Mol. Reprod. Dev. 71, 444–452 (2005).
Nozawa, Y. I. et al. Fused (Stk36) is a ciliary protein required for central pair assembly and motile cilia orientation in the mammalian oviduct. Dev. Dynam. 242, 1307–1319 (2013).
Eshel, D., Grossman, Y. & Priel, Z. Spectral characterization of ciliary beating: variations of frequency with time. Am. J. Physiol. 249, C160–C165 (1985).
Luk, C. K. & Dulfano, M. J. Effect of pH, viscosity and ionic-strength changes on ciliary beating frequency of human bronchial explants. Clin. Sci. (Lond.) 64, 449–451 (1983).
Lee, W. I. & Verdugo, P. Laser light-scattering spectroscopy: a new application in the study of ciliary activity. Biophys. J. 16, 1115–1119 (1976).
Verdugo, P. & Goldborne, C. E. Remote detection of ciliary movement by fiber optic laser-Doppler spectroscopy. IEEE Trans. Biomed. Eng. 35, 303–307 (1988).
Svartengren, K., Wiman, L. G., Thyberg, P. & Rigler, R. Laser light scattering spectroscopy: a new method to measure tracheobronchial mucociliary activity. Thorax 44, 539–547 (1989).
Paltieli, Y., Weichselbaum, A., Hoffman, N., Eibschitz, I. & Kam, Z. Laser scattering instrument for real time in-vivo measurement of ciliary activity in human fallopian tubes. Hum. Reprod. 10, 1638–1641 (1995).
Huang, D. et al. Optical coherence tomography. Science 254, 1178–1181 (1991).
Fujimoto, J. G., Pitris, C., Boppart, S. A. & Brezinski, M. E. Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. Neoplasia 2, 9–25 (2000).
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L. & Boppart, S. A. Optical coherence tomography: a review of clinical development from bench to bedside. J. Biomed. Opt. 12, 051403 (2007).
Oldenburg, A. L., Chhetri, R. K., Hill, D. B. & Button, B. Monitoring airway mucus flow and ciliary activity with optical coherence tomography. Biomed. Opt. Express 3, 1978–1992 (2012).
Liu, L. et al. Method for quantitative study of airway functional microanatomy using micro-optical coherence tomography. PLOS ONE 8, e54473 (2013).
Birket, S. E. et al. A Functional Anatomic Defect of the Cystic Fibrosis Airway. Am. J. Respir. Crit. Care Med. 190, 421–432 (2014).
Liu, L. et al. An Autoregulatory Mechanism Governing Mucociliary Transport Is Sensitive to Mucus Load. Am. J. Respir. Cell Mol. Biol. 51, 485–493 (2014).
Liu, L. et al. Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography. Nat. Med. 17, 1010–1014 (2011).
Jonas, S., Bhattacharya, D., Khokha, M. K. & Choma, M. A. Microfluidic characterization of cilia-driven fluid flow using optical coherence tomography-based particle tracking velocimetry. Biomed. Opt. Express 2, 2022–2034 (2011).
Huang, B. K., Gamm, U. A., Jonas, S., Khokha, M. K. & Choma, M. A. Quantitative optical coherence tomography imaging of intermediate flow defect phenotypes in ciliary physiology and pathophysiology. J. Biomed. Opt. 20, 030502 (2015).
Schmitt, J. M., Xiang, S. H. & Yung, K. M. Speckle in Optical Coherence Tomography. J. Biomed. Opt. 4, 95–105 (1999).
Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K. & Welch, A. J. In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. Opt. Lett. 22, 1439–1441 (1997).
Morgner, U. et al. Spectroscopic optical coherence tomography. Opt. Lett. 25, 111–113 (2000).
de Boer, J. F., Milner, T. E., van Gemert, M. J. C. & Nelson, J. S. Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography. Opt. Lett. 22, 934–936 (1997).
Häusler, G. & Lindner, M. W. “Coherence Radar” and “Spectral Radar”—New Tools for Dermatological Diagnosis. J. Biomed. Opt. 3, 21–31 (1998).
Lyons, R. A. et al. Fallopian tube ciliary beat frequency in relation to the stage of menstrual cycle and anatomical site. Hum. Reprod. 17, 584–588 (2002).
Mahmood, T., Saridogan, E., Smutna, S., Habib, A. M. & Djahanbakhch, O. The effect of ovarian steroids on epithelial ciliary beat frequency in the human Fallopian tube. Hum. Reprod. 13, 2991–2994 (1998).
Ittner, L. M. & Gotz, J. Pronuclear injection for the production of transgenic mice. Nat. Protoc. 2, 1206–1215 (2007).
Niwa, S. et al. KIF19A Is a Microtubule-Depolymerizing Kinesin for Ciliary Length Control. Dev. Cell 23, 1167–1175 (2012).
Mariampillai, A. et al. Speckle variance detection of microvasculature using swept-source optical coherence tomography. Opt. Lett. 33, 1530–1532 (2008).
William, K. J. & Krause, W. J. Krause’s Essential Human Histology for Medical Students. (Universal Publishers, 2005).
Noreikat, K., Wolff, M., Kummer, W., Kolle, S. Ciliary activity in the oviduct of cycling, pregnant and muscarinic receptor knockout mice. Biol. Reprod. 86, 120 (2012).
Clary-Meinesz, C. F., Cosson, J., Huitorel, P. & Blaive, B. Temperature effect on the ciliary beat frequency of human nasal and tracheal ciliated cells. Biol. Cell 76, 335–338 (1992).
Gardner, D. K. & Leese, H. J. Concentrations of nutrients in mouse oviduct fluid and their effects on embryo development and metabolism in vitro. J. Reprod. Fertil. 88, 361–368 (1990).
O’Connor, A. K. et al. An inducible CiliaGFP mouse model for in vivo visualization and analysis of cilia in live tissue. Cilia 2, 8 (2013).
Pritchett, K. R. & Taft, R. A. in The Mouse in Biomedical Research 2nd edn. (eds Fox, J. G. et al. ) Ch. 3 (Academic Press, 2007).
Merton, H. XX.—Studies on Reproduction in the Albino Mouse. III. The Duration of Life of Spermatozoa in the Female Reproductive Tract. P. Roy. Soc. Edinb. 59, 207–218 (1940).
Haller-Kikkatalo, K., Salumets, A. & Uibo, R. Review on Autoimmune Reactions in Female Infertility: Antibodies to Follicle Stimulating Hormone. Clin. Dev. Immunol. 2012, 762541 (2012).
Nonaka, S. et al. Randomization of Left–Right Asymmetry due to Loss of Nodal Cilia Generating Leftward Flow of Extraembryonic Fluid in Mice Lacking KIF3B Motor Protein. Cell 95, 829–837 (1998).
Larina, I. V. et al. Live imaging of blood flow in mammalian embryos using Doppler swept-source optical coherence tomography. J. Biomed. Opt. 13, 060506 (2008).
Tearney, G. J. et al. In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography. Science 276, 2037–2039 (1997).
Acknowledgements
This work was supported by grants R01HL120140, T32GM008231 and U54HG006348 from the National Institutes of Health as well as by the Optical Imaging and Vital Microscopy core at the Baylor College of Medicine.
Author information
Authors and Affiliations
Contributions
S.W. developed the technqiue, performed the experiments, analyzed the data and prepared the manuscript. J.C.B. performed experiments and contributed to the data analysis and the manuscript preparation. R.R.B. contributed to the genesis of the project and the manuscript preparation. I.V.L. conceived the idea, supervised the project and contributed to the experiments, the data analysis and the manuscript preparation.
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Electronic supplementary material
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Wang, S., Burton, J., Behringer, R. et al. In vivo micro-scale tomography of ciliary behavior in the mammalian oviduct. Sci Rep 5, 13216 (2015). https://doi.org/10.1038/srep13216
Received:
Accepted:
Published: