Abstract
Contact and projection electron radiography of static targets was demonstrated using a laser–plasma accelerator driven by a kilojoule, picosecond-class laser as a source of relativistic electrons with an average energy of 20 MeV. Objects with areal densities as high as 7.7 g/cm2 were probed in materials ranging from plastic to tungsten, and radiographs with resolution as good as 90 μm were produced. The effects of electric fields produced by the laser ablation of the radiography objects were observed and are well described by an analytic expression relating imaging magnification change to electric-field strength.
Similar content being viewed by others
Introduction
Understanding high-energy–density (HED) plasmas, inertial confinement fusion (ICF) implosions, and laser–plasma interactions (LPI’s) at large research facilities such as the OMEGA laser at the Laboratory for Laser Energetics (LLE), Laser Mégajoule at Commissariat à l’énergie atomique, the Z-machine at Sandia National Laboratories, and the National Ignition Facility at Lawrence Livermore National Laboratory is important for mitigating the factors prohibiting ignition in the search for a sustainable fusion energy source1, as well as to better understand other fundamental and radiation-driven physics. It is extremely difficult to characterize these events, which occur on a very small spatial scale (millimeter to micrometer) and very fast time scale (microsecond to picosecond), requiring a variety of diagnostic techniques that are constantly evolving.
To investigate the physical structure of compressed targets, laser-generated X-ray2,3 or proton radiography4,5,6,7 is typically used, with protons providing the extra feature of electromagnetic-field sensitivity. Although X-ray and proton probes are the standard laser-generated diagnostic, there is another laser-generated probe that has seen little use, namely, relativistic electrons. Small-scale HED research facilities have performed electron radiography of ultrafast laser–plasma interactions7,8,9,10,11,12, but this capability has never before been extended to kilojoule- or megajoule-class laser facilities. The work presented in this manuscript builds upon previous electron radiography (eRad) work using radio-frequency (rf) linear accelerators10,13,14,15 and small-scale lasers7,8,9,11,12,16,17 and extends it to kilojoule-class facilities using the already available picosecond lasers for electron-beam generation via laser–plasma acceleration (LPA)18,19.
Here, we report the first single-shot eRad images using an electron beam from a kilojoule-class LPA. Both contact and projection radiographs were obtained of static targets in materials ranging from plastic to tungsten, and resolutions as good as 90 μm were achieved. This work lays the foundation for future electron radiography of laser-driven targets at kilojoule- and megajoule-class facilities.
Background
Rf-powered linear accelerators generate monochromatic, low-emittance electron beams suitable for high-quality electron radiography10,13,14,15. Such systems, however, are rarely available at the same facilities as large HED drivers and cannot easily be installed for experiments because of cost and space constraints. Often these HED facilities have picosecond lasers available such as OMEGA EP, NIF-ARC (National Ignition Facility Advanced Radiograph Capability), PETAL, and Z-Petawatt lasers, which can be used for the efficient generation of relativistic electron beams via LPA techniques18. This method allows for electron beams to be generated for radiography without needing to add a rf linear accelerator to an HED facility. A laser-driven eRad system also possesses the temporal characteristics that could make for an ideal diagnostic of other picosecond-scale processes7,8,9,11,12 for which linear accelerators do not typically provide equivalent instantaneous electron flux and may suffer signal-to-noise ratio issues.
Electron radiography provides a complementary probe to existing X-ray and proton radiography techniques. Laser-generated electrons are able to penetrate more material than laser-generated protons at the available energies, as shown in Fig. 1. For example, a laser-generated proton of 15 MeV will be fully stopped by ~ 2 mm of plastic at standard density and temperature, while a 15-MeV electron will require multiple centimeters of plastic to be fully stopped20. Far more electrons of similar energy or higher will also be generated for given laser conditions, providing a further advantage to laser-generated electrons over protons5,18.
Typical mean/maximum probe energies generated on OMEGA-EP are 20/200 MeV for electrons, 15/60 MeV for protons and 8/100 keV for X-rays2,3,18,22,23,24. It can be seen in Fig. 1 that relativistic electrons are the most penetrating probes able to be generated with currently available lasers at HED facilities2,3,18,22,23,24. This penetration capability is crucial for radiographing targets at extreme densities, such as those used for ICF experiments25,26,27. Megavolt-scale X rays can have similar penetrative capabilities to that of relativistic electrons3 but are typically generated by first generating relativistic electrons of a much higher energy. Thus, more electrons can be sent to the target for the same laser input power verses Megavolt-scale X rays, and the signal-to-noise ratio can potentially be increased for the same experimental parameters.
Relativistic electrons are more sensitive to deflection by electric and magnetic fields for a given energy than protons, but have a higher ratio of electric to magnetic field sensitivity. The higher ratio of the magnetic- versus electric-field deflection sensitivity makes laser- generated electrons an excellent complement to laser protons for radiography of electromagnetic fields. This can be seen by comparing the magnetic rigidity Bρ ≡ B (dx/dθ) (the resistance of a charged particle to deflection from a magnetic field) to the equivalent electric-field deflection resistance Eρ ≡ E (dx/dθ) (“electric rigidity”), where B and E are the magnetic and electric fields and dx and dθ are change in position and angle, respectively28,29,30. Deriving in the limit of small deflections, the magnetic and electric rigidity are
and
The units for magnetic rigidity are Tesla meters per radians and the input is relativistic momentum p and charge q of the particle in question28,30. Electric rigidity depends on the particle momentum p, the particle mass m, the particle charge q, the velocity fraction of light speed β, and the speed of light c. The units of electric rigidity are volt-meter/meter per radian (in the present case, megavolt-meter/meter per radian is appropriate). The radian term is conventionally dropped when discussing magnetic rigidity28,30 and will also be dropped for the remainder of the paper for electric rigidity as well. Figure 2 shows a comparison of magnetic and electric rigidity for both protons and relativistic electrons with notable electron and proton energies from various laser and rf sources31 included. Energies up to 1 GeV are shown corresponding to today’s high-performing electron LPA’s23,32 and large proton LINACs31. LPA-generated electron beams are regularly created with energies as low as a few MeV33 and as high as ~ 8 GeV18,23,34. This capability for large variation in energy makes for a customizable radiography tool that can provide insight into a wide variety of targets at areal densities ranging from mg/cm2 to many g/cm2, integrated magnetic fields from 4.9 × 10−3 to 28 T-m, and integrated electric fields from 0.9 to 1000 MV-m/m based on the above variation in electron energy.
Relativistic electron radiography makes a great complement to proton radiography for laser-plasma experiments because of the much larger ratio of electric to magnetic rigidity compared to available protons at HED facilities4,5,6,22,31. The peak electron energies available18,23,32 also have a higher electric rigidity than the peak proton energies available at HED facilities4,5,6,7. With eRad, suspected fields can be probed with an entirely different type of charged-particle probe, confirming or disproving theories about field type and strength.
The sensitivity of relativistic electrons to magnetic fields also provides for the option to use magnetic optics to improve resolution. Without the use of magnetic optics, charged-particle radiography is limited to the inherent resolution of the source size combined with the scatter-induced object blur and any imaging system resolution limits. Resolutions as low as 8.8 μm have been seen in previous eRad experiments with magnetic optics14, and potentially ~ 0.06 μm with further refinement13.
For radiography objects much smaller than the radiation length (the characteristic amount of material that a given charged particle can traverse before losing 1/e of its energy)35, the resolution will be dominated by the size of the source of particles13. This limitation is also commonly seen in laser proton radiography experiments and provides resolutions comparable to the drive laser spot size of several μm36. If the target is thick enough to provide multiple scatters of the source particles, then the radiography resolution becomes dominated by scatter-based blurring. Optimal electron radiography occurs near 1/10th of a radiation length, while ~ 1/2 of a radiation length ends up absorbing nearly all of the probing radiation13. The theoretical resolution of electron radiography can be modeled with the following analytic equations37:
and
Theoretical resolution is determined by adding the contributions of electron scattering (x), image plate (or other imaging system) resolution (ip) and source size (s) in quadrature in Eq. (3). Scatter-based blur is determined by Eq. (4), where d is the drift distance from the radiography target to the imaging plane, M is the magnification of the image, h is the thickness of the target, N is the number density of the material, Z is the atomic number, re is the classical electron radius, and γ is the relativistic Lorentz factor. Equation (5) provides for imaging-system–induced blur with ΔI being the imaging system resolution in the image plane and M is the magnification of the object as before. Source resolution is then determined with Eq. (6) with ΔS being the size of the source and M is the magnification of the object.
These equations do not account for particle energy spread or bremsstrahlung-induced background, which have both been found to affect the resolution during eRad experiments14. The use of magnetic optics can mitigate the blur over a limited energy band by focusing the scattering particles onto a focal plane as well as eliminating blur associated with geometric and magnification effects. Particles outside of the focal energy range can be eliminated through the use of an energy collimator within a bending magnet and the lowest energy particles absorbed with filters, which also has the effect of bending the charged-particle focal plane outside of the line of sight of the unwanted bremsstrahlung radiation generated by the electron–target interaction13.
Experimental setup
The experiments were performed using the OMEGA EP laser, which has a central wavelength of 1054 nm and a pulse duration of 700 ± 100 fs. The laser was spatially apodized from the typical f/2 geometry to f/5 to improve the focal quality and increase the Rayleigh length. Laser pulse energy was varied between 25 and 120 J and the R80 spot size (the radius of the area containing 80% of the laser energy) varied in the range 13.9 to 16.2 μm. The laser was focused 500 μm inside a Mach-5 gas jet produced by a 6-mm nozzle with gas pressures ranging from 80 to 350 psi. This configuration has been found to produce a polychromatic, microcoulomb-class electron beam with a mean energy of 20 MeV\(\pm \, 5\) with some extreme outliers at \(\pm \, 10\) MeV18. Several measured samples of the electron energy spectra can been in Supplementary Appendix A.
The experiment was performed in two different configurations: a contact eRad configuration and a projection eRad configuration. For the contact configuration (Fig. 3a), radiography test objects were placed in a detector stack consisting of 12.5-μm Al shielding, two MS image plates (IP’s), and the radiography test objects (Fig. 3b), followed by an additional MS image plate. The detector pack was held at a distance of 56 cm from the laser focus in front of an electron–positron–proton spectrometer (EPPS)38. The image plates in front of the radiography test objects are used to measure the nonuniform transverse electron beam profile, which could then be subtracted from the radiograph to flatten the image for clarity39. The radiography test objects contained a series of steps ranging in thickness from 0.571 ± 0.127 to 4.000 ± 0.127 mm in 0.571 ± 0.127-mm steps Each step thickness contained a series of holes with diameters ranging from 1.270 ± 0.076 to 2.540 ± 0.076 mm. The target design was chosen to provide a variety of features to measure the radiographic performance of the LPA electron beam in contact radiography geometry. Six different materials were radiographed: Cu (110 series), Sn, Al (1100 series), W (MT-17C), Ti, and stainless-steel 304L, covering a wide range of Z numbers and densities.
For the projection radiography experiments shown in Fig. 3c, radiography test objects (Fig. 3d) were placed 14.2 mm from laser focus and mounted on silicon carbide stalks. Note that the majority of the drive laser energy is transmitted through the gas jet and impacts the projection radiography object. It is estimated that ~ 20 to ~ 100 J of laser energy at intensities of ~ 3 × 1014 to ~ 1 × 1015 W/cm2 impacted the radiography test objects with the laser beam head arriving ~ 45 fs before the head of the electron beam40 and the remaining laser overlapping the electron beam. The laser then drives electric fields of the order of ~ 1 GV/m in the plasma sheath generated on the front face of the object. The electron beam was imaged via two stacked image plates wrapped in 25-μm aluminum foil placed in a near target arm (NTA) and varying in imaging distance from 3.58 to 33.58 cm from the radiography test object.
These radiography test objects were much smaller and thinner than the contact radiography test objects because of debris concerns for the laser optics. These smaller and thinner test objects are much more realistic stand-ins for future laser-driven HED targets and were made of the same W, Cu, Ti as above as well as solution-cast polystyrene to cover a wide range of target Z and density options. The radiography objects had thicknesses ranging from 0.125 ± 0.012 to 0.375 ± 0.037 mm, areal densities ranging from 0.025 to 0.713 g/cm2 and hole sizes ranging from 0.25 ± 0.03 to 0.5 ± 0.03 mm (Fig. 3d). The radiation lengths, radiographed thicknesses, and optimal radiation lengths (~ 10% of a full radiation length) for all materials radiographed in these experiments are shown in Fig. 4.
It can be seen that the lowest Z projection and contact radiograph objects are nowhere near a radiation length, or even a significant fraction of one, which will result in very little scattering. However, the W projection radiography objects are already effectively at an optimum thickness for scatter-dominated radiography and the W contact radiography object achieves a full radiation length at the thickest. Thus, little electron transmission can be expected through the thickest tungsten objects, while the thinnest polystyrene objects will be expected to barely scatter any electrons at all.
Results and discussion
In both configurations, resolution is repeatedly measured by fitting an error function to a box out taken over edges and features of interest39. Total object sizes are then measured to check for magnification errors. Error in measurements is derived via repeated measurements of the same section and then the standard deviation of these measurements used.
Figure 5 shows that the resolution in the contact eRad configuration degraded with increasing thickness and Z number of radiography target in rough agreement with the theoretical predictions, although there were outliers in the thinner tungsten sections. The poor fit of the theoretical prediction with the thinner tungsten sections can be explained via bremsstrahlung blurring, where the X-rays generated from the electrons interacting with the target decrease the signal-to-noise ratio and increase the effective source size due to their cone of emission. Mid- to high-Z materials in this thickness range are considered ideal electron beam bremsstrahlung convertors for X-ray production for applications41,42 and thus the blurring will be worse. Thicker sections will self-absorb the bremsstrahlung and trend toward the idealized predictions from Eqs. (3)–(6), as seen by the relatively good fits with the thickest tungsten sections. This is further supported by the much better theoretical fit with the aluminum sections, which had minimal bremsstrahlung production. Bremsstrahlung blurring has motivated the use of magnetic optics to separate out the electrons from the X-ray source in previous eRad experiments13.
The drift distance was taken to be the radiography object thickness at the point of measurement with a magnification of 1 using Eqs. (3)–(6) for calculating theoretical resolution. Image plate pixel size is taken to be ~ 100 μm43 and the source size is taken to be that of the laser, which ranged from 13.9 to 16.2 μm.
The effect of radiography object Z number on projection radiography was tested, as seen in Fig. 6. All radiography objects were imaged with the NTA 6.58 cm from the object and 8 cm from the laser focal point. The electron beam is assumed to be born from the exit of the gas jet and is treated as a point source equal in size to the laser focal spot. For theoretical calculations of resolution, source size and pixel size were the same as above, but magnification was 5.3 and object thickness taken to be the average of 0.3125 mm for the radiography object. The resolution was found to be insensitive to the radiography test object Z number.
This response is promising for future use as a radiography platform for laser-driven targets but does not match theoretical expectations from Eqs. (3)–(6), which predict a roughly linear relationship with radiography test object Z for the same object thickness (Fig. 6). It should be noted that the objects vary over an order of magnitude in areal density as the Z number increases. This flat response with Z could be caused by electron-plasma–induced blur from the drive laser generating a surface plasma on the front face of the radiography test object or from the above-mentioned bremsstrahlung blurring dominating over the minimal scatter of the electrons that would happen in such low density, low-Z objects.
To test the radiographic capabilities of the projection configuration at different imaging distances, repeat radiographs of a tungsten radiography test object were performed with the image plate pack placed at 3.58, 6.58, 22.08 and 33.58 cm from the radiography test object (Fig. 7). Theoretical resolution was calculated using the same source size, pixel size and object thickness as for Fig. 6, but now with varying magnifications. The resolution held roughly constant with imaging distance, indicating that resolution is limited by scattering rather than by source size and that gains in resolution can only be had with the inclusion of magnetic optics. Although the exact resolutions were not well predicted by the theoretical predictions, the general trend was captured. As imaging distance increases, the magnification increases, which improves resolution. This improvement is countered, however, by the increased distances allowing the scattered electrons to undergo further displacement and thus increasing the imaging blur, degrading the resolution of the image. This is the primary motivation for the addition of magnetic optics in charged-particle radiography schemes as the large angle scattered particles are removed from the image and the small angle scatters are refocused back onto the imaging plane13. Bremsstrahlung blurring can also be avoided by imaging the beam outside of the direct line of sight of the radiography target using dipole magnets. In this case, no such optics were used and, as such, the resolution remains limited to 90 μm in the best radiographs with W radiography objects and the NTA placed 3.58 cm from the radiography object as seen in Fig. 7.
An additional phenomenon of interest was seen with projection radiography during analysis. The measured magnification of the image is persistently ~ 1.5× smaller than would be expected from the distance between the source, target, and image plate. We conjecture that electrostatic focusing from laser-plasma generated fields on the front face of the radiography object is the cause of this discrepancy. Laser-generated fields of the order of ~ 1 GV/m have been reported at similar laser intensities as are generated on the front face of the radiography objects4,44,45,46,47 and G4 Beamline simulations48 indicate similar changes in image magnification at similar electric-field strengths. Using the concept of electrostatic rigidity (Eq. 2), we can derive an analytic estimate for the electric field corresponding to the observed deflection, which is given by Eq. (7). Full details of this derivation are included in Appendix B and representative simulations results in Supplementary Appendix C.
Here, R and and R′ are the expected and measured size of the radiography target, respectively, while r is the original size of the object being analyzed. Object radius is r, while y and x are the distance from the source to the image plane and target to the image plane, respectively. The variables p, q, and β are the same relativistic and particle specific terms from Eq. (2) and \(\delta x\) is the assumed field length. Note that changes in the assumed field length drastically change the predicted electric field. This equation does not account for the gradients actually expected in the plasma-generated electric fields4,44,45,46,47 and an average field is assumed for a given distance. Assuming a weighted average electron energy of 20 MeV \(\pm \, 5\)18, a field length of 0.3 mm (an average length of the target) for \(\delta x\), and using the experimental parameters for each shot taken, an estimate of the required electric field can be made and was found to average ~ 3 GV/m. For reference, this is roughly 3% of the anticipated peak laser electric field on target. The estimate is highly dependent on assumed field length and lack of electric field gradients; however, it is useful for an initial estimate of order of magnitude. Comparably short (~ 100 fs) timescales with 1014–1015 W/cm2 intensity have not been a typical parameter range for experiments or simulations of electric field generation in laser-driven targets, which have usually focused on longer timescales4 or higher intensities44,45,46,47. Future work is needed to better quantify sheath field formation under these conditions. The estimated electric fields are plotted versus laser energy in Fig. 8.
Estimated electric field increased roughly linearly with laser energy on target within a specific intensity range, as expected by previous studies on the topic44,45,46,47. These results cover a wide range of materials, which can help to explain the variations in measured electric field for a given laser energy. The analytic method derived here can be used to estimate large-scale electric fields in future laser-driven experiments and is applicable to all forms of charged-particle radiography.
Conclusion and future work
An eRad platform based on an LPA driven by a kilojoule, picosecond-class laser was tested on a wide variety of targets and imaging configurations. Resolutions as good as 90 μm were seen for projection radiography with a magnification of 3.61. Imaging resolution degraded with thickness of the target material and with Z number of the material as expected. Increased magnification did not improve resolution, indicating that resolution is limited by scattering rather than by source size. This motivates the addition of magnetic optics and collimators on future experiments to mitigate angular blur and improve resolution. Electric fields from laser irradiation of the radiography target were also measured, and an analytic equation derived to estimate electric fields from the change in magnification of the image. Future experiments will radiograph a wide variety of laser-driven targets to measure electric- and magnetic-field generation in laser–solid interactions and strongly shocked materials for ICF and HED applications.
Data availability
The data that support the plots within this paper and other finding of this study are available from the corresponding author upon reasonable request.
References
Edwards, M. J. et al. Progress towards ignition on the National Ignition Facility. Phys. Plasmas 20, 070501 (2013).
Dewald, E. L. et al. X-ray streaked refraction enhanced radiography for inferring inflight density gradients in ICF capsule implosions. Rev. Sci. Instrum. 89, 10G108 (2018).
Courtois, C. et al. High-resolution multi-MeV X-ray radiography using relativistic laser-solid interaction. Phys. Plasmas 18, 023101 (2011).
Rygg, J. R. et al. Proton radiography of inertial fusion implosions. Science 319, 1223–1225 (2008).
Zylstra, A. B. et al. Using high-intensity laser-generated protons to radiograph directly driven implosions. Rev. Sci. Instrum. 83, 013511 (2012).
Li, C. K. et al. Proton radiography of dynamic electric and magnetic fields in laser-produced high-energy-density plasmas. Phys. Plasmas 16, 056304 (2009).
Wan, Y. et al. Direct observation of relativistic broken plasma waves. Nat. Phys. 18, 1186–1190 (2022).
Schumaker, W. et al. Ultrafast electron radiography of magnetic fields in high-intensity laser-solid interactions. Phys. Rev. Lett. 110, 015003 (2013).
Raj, G. et al. Probing ultrafast magnetic-field generation by current filamentation instability in femtosecond relativistic laser-matter interactions. Phys. Rev. Res. 2, 023123 (2020).
Zhang, C. et al. Measurements of the growth and saturation of electron Weibel instability in optical-field ionized plasmas. Phys. Rev. Lett. 125, 255001 (2020).
Zhou, Z. et al. Visualizing the melting processes in ultrashort intense laser triggered gold mesh with high energy electron radiography. Matter Radiat. Extremes 4, 065402 (2019).
Zhang, C. J. et al. Femtosecond probing of plasma wakefields and observation of the plasma wake reversal using a relativistic electron bunch. Phys. Rev. Lett. 119, 064801 (2017).
Merrill, F. E. Imaging with penetrating radiation for the study of small dynamic physical processes. Laser Part. Beams 33, 425–431 (2015).
Merrill, F. E. et al. Demonstration of transmission high energy electron microscopy. Appl. Phys. Lett. 112, 144103 (2018).
Merrill, F. et al. Electron radiography. Nucl. Instrum. Methods Phys. Res. B 261, 382–386 (2007).
Hazra, D., Mishra, S., Moorti, A. & Chakera, J. A. Electron radiography with different beam parameters using laser plasma accelerator. Phys. Rev. Accel. Beams 22, 074701 (2019).
Xiao, C. et al. Direct imaging with hundreds of MeV electron bunches from laser wakefield acceleration. Phys. Stat. Sol. A 218, 2000371 (2021).
Shaw, J. L. et al. Microcoulomb (0.7 ± 0.4/0.2 μc) laser plasma accelerator on OMEGA EP. Sci. Rep. 11, 7498 (2021).
Albert, F. et al. Betatron X-ray radiation in the self-modulated laser wakefield acceleration regime: Prospects for a novel probe at large scale laser facilities. Nucl. Fusion 59, 032003 (2018).
Berger, M. J., Coursey, J. S., Zucker, M. A. & Chang, J. ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions (Ver. 2.0.1). https://www.nist.gov/pml/stopping-power-range-tables-electrons-protons-and-helium-ions [17 August 2018]. https://doi.org/10.18434/T4NC7P (National Institute of Standards and Technology, 2022).
Berger, M. J. et al. Xcom: Photon cross sections database. In NIST Standard Reference Database 8 (XGAM) (ver. 3.1). https://doi.org/10.18434/T48G6X (2022).
Flippo, K. et al. OMEGA EP, laser scalings and the 60 MeV barrier: First observatios of ion acceleration performance in the 10 picosecond kilojoule short-pulse regime. J. Phys. Conf. Ser. 244, 022033 (2010).
Gonsalves, A. J. et al. Laser-heated capillary discharge plasma waveguides for electron acceleration to 8 GeV. Phys. Plasmas 27, 053102 (2020).
Higginson, A. et al. Near-100 MeV protons via a laser-driven transparency-enhanced hybrid acceleration scheme. Nat. Commun. 9, 724 (2018).
Clark, D. S. et al. Three-dimensional simulations of low foot and high foot implosion experiments on the National Ignition Facility. Phys. Plasmas 23, 056302 (2016).
Craxton, R. S. et al. Direct-drive inertial confinement fusion: A review. Phys. Plasmas 22, 110501 (2015).
McBride, R. D. et al. A primer on pulsed power and linear transformer drivers for high energy density physics applications. IEEE Trans. Plasma Sci. 46, 3928–3967 (2018).
Lee, S. Y. Accelerator Physics 2nd edn. (World Scientific Publishing Company, 2004).
Kugland, N. L., Ryutov, D. D., Plechaty, C., Ross, J. S. & Park, H.-S. Invited article: Relation between electric and magnetic field structures and their proton-beam images. Rev. Sci. Instrum. 83, 101301 (2012).
Krinsky, S. Particle accelerator physics. Synchrotron. Radiat. News 7, 39A (1994).
King, N. S. P. et al. An 800-MeV proton radiography facility for dynamic experiments. Nucl. Instrum. Methods Phys. Rev. A 424, 84–91 (1999).
Kim, H. T. et al. Stable multi-GeV electron accelerator driven by waveform-controlled PW laser pulses. Sci. Rep. 7, 10203 (2017).
Bussolino, G. C. et al. Electron radiography using a table-top laser-cluster plasma accelerator. J. Phys. D Appl. Phys. 46, 245501 (2013).
Esarey, E., Schroeder, C. B. & Leemans, W. P. Physics of laser-driven plasma-based electron accelerators. Rev. Mod. Phys. 81, 1229–1285 (2009).
Workman, R. L. et al. Review of particle physics. Prog. Theor. Exp. Phys. 2022, 083C01 (2022).
Campbell, P. T. et al. Proton beam emittance growth in multipicosecond laser-solid interactions. New J. Phys. 21, 103021 (2019).
Nassiri, A. Stopping Power and Scattering Angle Calculations of Charged Particle Beams Through Thin Foils, Report LA-165 (Argonne National Laboratory, 1991).
Ayers, S. L. Electron Positron Proton Spectrometer for Use at Laboratory for Laser Energetics, Report LLNL-TR-427769 (Lawrence Livermore National Laboratory, 2010).
Bruhaug, G. M. Laser-plasma-accelerator-driven electron radiography on the OMEGA EP laser. In Presented at the North American Particle Accelerator Conference, Albuquerque, NM, 7–12 August 2022 (2022).
Lemos, N. et al. Self-modulated laser wakefield accelerators as X-ray sources. Plasma Phys. Control. Fusion 58, 3. https://doi.org/10.1088/0741-3335/58/3/034018 (2016).
Tsechanski, A., Fedorchenko, D., Starovoitova, V. & Galperin, A. Converter optimization for photonuclear production of Mo-99. Nucl. Instrum. Methods Phys. Res. B 461, 118–123 (2019).
Halbleib, J. A., Lockwood, G. J. & Miller, G. H. Optimization of bremsstrahlung energy deposition. IEEE Trans. Nucl. Sci. 23, 1881–1885 (1976).
Fiksel, G., Marshall, F. J., Mileham, C. & Stoeckl, C. Note: Spatial resolution on fuji bas-tr and bas-sr imaging plates. Rev. Sci. Instrum. 83, 086103 (2012).
Dubois, J. L. et al. Target charging in short-pulse-laser–plasma experiments. Phys. Rev. E 89, 013102 (2014).
Beg, F. N. et al. A study of picosecond laser-solid interactions up to 1019 W cm-2. Phys. Plasmas 4(2), 447–457. https://doi.org/10.1063/1.872103 (1997).
Poyé, A. et al. Thin target charging in short laser pulse interactions. Phys. Rev. E 98(3), 1–12. https://doi.org/10.1103/PhysRevE.98.033201 (2018).
Gitomer, S. J. et al. Fast ions and hot electrons in the laser–plasma interaction. Phys. Fluids 29(8), 2679. https://doi.org/10.1063/1.865510 (1986).
Roberts, T. G4 Beamline 3.06. https://www.muonsinc.com/Website1/G4beamline (Accessed 24 June 2022).
Acknowledgements
This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0003856 and under Award Number 89233218CNA000001, the U.S. Department of Energy under Awards DE-SC00215057, the University of Rochester, and the New York State Energy Research and Development Authority. Partial funding for G. W. Collins and J. R. Rygg was from US Department of Energy, Office of Science, Fusion Energy Sciences under award number DE-SC0020340. This report was prepared as an account of work sponsored by an agency of the U.S. Government. Neither the U.S. Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the U.S. Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the U.S. Government or any agency thereof.
Author information
Authors and Affiliations
Contributions
G.B. wrote the main manuscript text and prepared the figures. H.R., J.R.R., M.S.F. and J.L.S. all provided substantial input into the manuscript and final figure design. All authors reviewed the manuscript and assisted in the data collection described therein.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Bruhaug, G., Freeman, M.S., Rinderknecht, H.G. et al. Single-shot electron radiography using a laser–plasma accelerator. Sci Rep 13, 2227 (2023). https://doi.org/10.1038/s41598-023-29217-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-29217-4
- Springer Nature Limited