Abstract
Establishing accurate structure–property relationships for intervertebral disc annulus fibrosus tissue is a fundamental task for a reliable computer simulation of the human spine but needs excessive theoretical-numerical-experimental works. The difficulty emanates from multiaxiality and anisotropy of the tissue response along with regional dependency of a complex hierarchic structure interacting with the surrounding environment. We present a new and simple hybrid microstructure-based experimental/modeling strategy allowing adaptation of animal disc model to human one. The trans-species strategy requires solely the basic knowledge of the uniaxial circumferential response of two different animal disc regions to predict the multiaxial response of any human disc region. This work demonstrates for the first time the determining role of the interlamellar matrix connecting the fibers-reinforced lamellae in the disc multiaxial response. Our approach shows encouraging multiaxial predictive capabilities making it a promising tool for human spine long-term prediction.
Similar content being viewed by others
Introduction
The intervertebral disc is the most critical body part due to its essential and mandatory role during the daily activities such as work, sport, walking or even while only standing up without any movement. It is always subjected to multiaxial loadings increasing its internal local stresses which could lead to disc damage, hernia and severe pain1. Because of the complex couplings existing between microstructure at different scales, intrinsic properties (viscosity and nonlinearity), internal fluid flow and external loading mode, the knowledge of stress distribution in disc needs to call computer simulations. Over the last four decades, it was an important subject of research but, to date, there is no disc computational model that introduces the entire set of features. The first contributions modeled the disc as an elastic tangled extracellular matrix (ECM) solid phase rigidified by elastic collagen fibers (CFs)2,3,4,5,6. Then, biphasic models appeared adding the fluid phase to the disc structure and taking into account its diffusion inside the disc7,8,9,10. Finally, biphasic models were extended in order to incorporate the ECM negative charges effect and their influence on the fluid movement and intradiscal osmotic pressure in the loaded and unloaded states11,12,13,14. In the most recent publications, the time-dependency of the soft tissue response is neglected. This is obviously not consistent with the viscoelastic insights of the different disc components12,13,15 but also with the fluid transfer inside and outside the disc that affects largely the biochemical volumetric behavior of the tissue16,17,18. As common weak points, most of recent models need plenty of experimental testing sets in order to calibrate, fit and design them. Moreover, as mentioned in the literature, it is not possible to predict the multiaxial behavior of the disc by means of uniaxial data19,20. As a consequence, for each local region of the disc a new experimental test should be established for the construction of each uniaxial and multiaxial model, and the identification of a new set of parameters corresponding to each test is required19,20,21,22 or a fitting procedure including all uniaxial and multiaxial data that leads to non-accurate results for both data9,23,24. Also, the construction of an accurate heterogeneous model taking into account the different radial and circumferential microstructure features of the disc requires exploring and identifying the corresponding related parameters of each region. No model until now is able to predict the uniaxial behavior of some disc regions based only on their microstructure components and to extend this behavior in order to predict the multiaxial response of the tissue. The actual models are able to estimate stress levels inside the disc with a completely wrong tissue volumetric deformation. In this regard, in the most recent models17,18, the interlamellar (ILM) matrix connecting the fibers-reinforced lamellae was introduced as a key structural factor of the inter-layer fluid transfer mechanism responsible for the tissue transversal behavior in the axial and radial disc directions. Strictly speaking, the structural contribution of this zone cannot be overlooked25,26,27,28,29,30,31,32 but its exact role in the disc biomechanics remains still mysterious.
This work addresses the problem of the multiaxial mechanics prediction of human disc. The main objective is to provide a quantitative prediction of the multiaxial response of a complete human disc with a minimum of experiments by means of a hybrid trans-species experimental/modeling strategy requiring the basic knowledge of the uniaxial circumferential response of only two different animal disc regions. Different model simulations are designed based upon well-known experimental tests issued from the literature in order to perfectly approve the model validity under identical conditions. As far as we know, a few experimental data are available in the literature for uniaxial stretching33,34,35, biaxial stretching19,20 and shearing36 tests often conducted under different testing conditions (Other publications could be found in the literature but they are limited to a single annulus region or present only one case of biaxial loading or shear response of a single shear mode). Our approach, fully three-dimensional, incorporates the different intrinsic and microstructure features that play a key role in the disc multiaxial response: ECM viscoelasticity, osmo-induced ECM swelling, CFs content/orientation and ILM matrix. Its principle advantage is its ability to be used almost under any experimental conditions reported in the open literature including variations in specimen shape and loading conditions in terms of strain rate and maximum strains in order to reproduce exactly the effectuated test. The model results are investigated and correlated to the different physiological movements and important conclusions are deduced.
Results
Uniaxial stretching path along with regional effects
Uniaxial stretching responses were reproduced in-silico for specimens extracted from four different circumferential and radial disc regions (AO, PO, AI and PI) as shown in Fig. 1. The circumferential stress–strain and transversal responses of the four regions are reported in Fig. 2. The AO and AI regions were used to identify the fluid kinetics and the CFs parameters inside human intervertebral disc using a hybrid experimental/modeling strategy as described in Fig. 1. The latter will be discussed in details in “Methods” section. The response of the remaining disc regions, namely PO and PI, was then predicted by adapting well-known microstructure features in terms of CFs content/orientation and water content. The fitted and predicted numerical curves show an excellent agreement with the regional experimental results of Ebara et al.34 and Baldit et al.16. The behavior highlights a direct relation between the overall soft tissue mechanics, in terms of stiffness and Poisson’s ratio, and the microstructures along with the regional (circumferential and radial) variation in CFs content/orientation. The predicted slopes of the stress–strain curves of the posterior regions are lower than those obtained for the anterior regions. As well, the outer annulus is stiffer than the inner annulus. Quite interestingly, a very small radial deformation of the inner disc region compared to the outer disc region is obtained. The circumferential deformation is almost regional independent and its variation is negligible from a region to another. The very soft PI response reported for multilamellar or single lamellar specimens34,35 are impossible to catch with the model along CFs content is used as input data whereas it could almost be obtained by considering a non-fibrous ECM. The fibers content effect on the PI stiffness was investigated trying to find good explanations about this finding. An effective CFs content is suggested inspired from the microscopic observations of Tsuji et al.37 and Smith and Fazzalari38 who noticed a non-well-arranged CFs in the PI region compared to others. The stress–strain behavior was reproduced under different amounts of effective CFs and the corresponding stiffness was calculated and compared to the experimental results in Fig. 2. The effective CFs content shows a high ability to describe the low PI rigidity. Lower effective CFs content induces a lower rigidity modulus and a lower slope of the stress–strain conduct.
It is worth noticing that the model parameters were fitted using the uniaxial stretching data and the identified set of model parameters was used to generate the multiaxial predictions without any change or adjustment.
Biaxial stretching paths
The predictions in terms of AO biaxial stretching responses are plotted for different biaxial strain ratios in Fig. 3. The in-silico results are compared to the typical in-vitro experimental results of O’Connell et al.20 reproducing the same experimental conditions. A global view at these plots shows that the rigidity of the specimen is affected by the biaxial strain ratio. The stress levels obtained under different biaxial cases are higher than the uniaxial stress levels. The strain ratio has a larger effect on the axial stresses than the circumferential ones. The experimental results show the same effect. For the strain ratios 1:0 and 0:1, the circumferential stress is higher than the axial stress. This is also observed for the strain ratio 1:2. For the strain ratio 2:1, a higher axial stress is obtained as also experimentally remarked.
Shearing paths
The annulus shearing responses were predicted for specimens subjected to the three different shear modes illustrated in Fig. 4. These loading modes translate the different loading cases occurring under torsional and bending physiological movements. The shear mode 12 corresponds to the interlamellar shear generated especially under spinal torsion due to the relative movements between lamellae and between the inner and outer annulus regions. The shear mode 13 corresponds to the shearing generated by the adjacent vertebrae on the annulus under torsional movement due to the relative motion between the upper and lower disc surfaces. The shear mode 23 corresponds to the shearing generated by the relative displacement of the inner and outer disc regions under especially flexion movement. The predicted shear modulus was computed under the different shear modes and compared to the experimental results of Iatridis et al.39 and Fujita et al.36. The in-silico results are found slightly higher than the experimental observations but the same trends are observed for the three modes. The mode 12 gives the lowest shear modulus and the mode 13 gives the highest shear modulus while the 23 shear modulus is in between. As well, the outer region shows higher shear modulus than the inner disc region. In order to analyze these modes locally, the local shear stress fields of the three modes are plotted in Fig. 5. Important insights are observed. For all the modes the local stress levels in the lamellae and ILM zones are higher in the outer disc region than the inner one. Under the 12 shear mode the highest stress levels are observed in the ILM zones unlike the 13 and 23 shear modes where the highest stresses are observed in the lamellae. While comparing the 23 and 13 modes we can notice that for the first one the highest stress concentrations are similar in all the lamellae but in the second one the highest concentrations are in the lamellae containing only fibers oriented towards the displacement direction. The contribution of the different local annulus zones to the shear disc mechanics under the daily physiological movements is investigated and the probability of damage initiation under these different modes is discussed.
Discussion
The tensile stress–strain response of the annulus fibrosus is highly dependent on the regional variation of the CFs content/orientation33,35. Due to a higher CFs content, the outer annulus is stiffer than the inner annulus while the CFs angle difference leads to stiffer anterior regions than their posterior counterparts. This is a basic two-phase composite understanding in which the effective contributions of the ECM and the oriented CFs phases to the tensile stress–strain response are integrated. The regional variation of the negative charges content in the proteoglycans, decreasing from the nucleus to the outer disc region, leads to a variation in the ionic transfer by fluid exchange resulting in a variation of the transversal response translated by the Poisson’s ratio. The Poisson’s ratio related to the radial deformation is negative with higher values in the inner disc region compared to the outer disc region. Taking into account structural features and fluid exchange allows simulating the auxetic response of the tissue. In the meantime, the Poisson's ratio related to the axial deformation is not affected by the microstructure features and is almost the same for all the studied disc regions. The model shows that the Poisson’s ratio is principally influenced by the water content and the swelling of the ILM zones. As well, the presence of the high CFs content in the outer disc region compared to the inner one retards more the fluid flow and decreases its content which affects in turn the tissue swelling and the radial strains. On the other side, the Poisson's ratio related to the axial deformation is higher than 1 for the four regions and it is less sensible to the microstructure variation compared to the Poisson’s ratio related to the radial deformation, its value being relatively constant throughout the annulus. The PI region has experimentally the lowest rigidity that could correspond to the non-fibrillar ECM modulus due to the non-well-arranged and high dispersion of CFs37,38. The calculation of an effective oriented fibers content relating not only the fibers volume fraction but also considering their arrangement helped to vary the rigidity and to reach the low rigidity levels.
Our hybrid experimental/modeling strategy leads to drastically reduce the amount of experimental work needed to characterize the complete human disc behavior thanks to an accurate and effective chemo-mechanical microstructure-based approach. Modeling the annulus uniaxial stretching in the circumferential direction (representative of the disc compression mechanics) gives a lot of fruitful information and new explanations about the disc chemo-mechanical interactions as well as the different phenomena occurring in the disc. Nonetheless, predicting more realistic and complex spine movements requires the simulation of accurate annulus behavior under multiaxial (biaxial and shear) loadings.
Because it is constrained radially by the nucleus and axially by the adjacent vertebrae, the biaxial deformation of the annulus represents a more realistic loading case. The circumferential and axial stresses under different biaxial strain levels and strain ratios give similar results than those previously experimentally observed in the literature20. The annulus rigidity under different biaxial cases are higher than the uniaxial rigidity and the stress levels under the same maximum strain are relatively higher which have been also noticed experimentally19,40. The strain ratio shows as well a high effect on the biaxial behavior of the annulus especially on the axial stress. Many recent numerical and analytical models tried to compute the shear stress inside the disc under uniaxial loadings29,41 due to their simplicity. Only one recent contribution14 succeeded to reproduce the multiaxial behavior of the annulus based on the uniaxial behavior of the disc. Unfortunately, this contribution considered only the preloading free swelling effect and did not take into account the chemical coupling inside the disc with the surrounding environment and the related time-dependent behavior under mechanical loading that is always present during the physiological complex movements18. This coupling affects largely the transversal deformations which could lead to completely wrong results especially under biaxial tests. As well, it is considered that the Poisson’s ratios of the annulus related to axial and radial directions are constant and their values are between 0 and 0.5 which is proven experimentally to be wrong16,17,18. The annulus behavior under shearing is very important and could be of a prime interest while studying the disc biomechanics under especially bending and torsion movements. The latter are common mechanical loadings during the different daily spinal motions42 and generate shearing inside the disc that could lead to many disc dysfunctions when combined with other axial loads. Numerically, the 12 shear modulus is lower than the 23 shear modulus which is also lower than the 13 shear modulus. All moduli of the outer specimens are found higher than the internal ones for the same shear mode. The latter difference is confirmed by the same experimental conduct observed in the literature36,43. The shear predictions reveal very interesting observations. The lowest shear stress levels are observed under the 12 shear mode but occurred throughout the disc with a higher concentration in the non-fibrillar ILM zones that are much weaker than the adjacent lamellae increasing the risk of annulus delamination. This has been also observed experimentally in many contributions in the literature suggesting the contribution of especially the ILM connections and the lamellar fiber matrix interactions to this shearing mode43. The highest stresses for the 23 and 13 shear modes are observed in the lamellae. Nonetheless, only the lamellae with fibers oriented towards the loading direction are subjected to the maximum stress values in the mode 13. Under the 23 shear mode all the lamellae are subjected to those high stresses with higher maximum stress values compared to those observed in the 13 shear mode. This could be explained by the relation between the shear modulus of these two modes and the oriented CFs that was observed in previous experimental contributions43. While relating these shear modes to physiological movements we could notice that the 12 and 23 shear modes are more related to the torsional movements produced under twisting body actions as shown in Fig. 5 generating the highest stresses in the lamellae and the ILM zones as well. The 23 shear mode, related to bending and lateral bending body movements, generates moderate stress levels in the lamellae and very low stresses in the ILM zones. These results highlight for the same shear strains the high damage risk under torsional body movements making it the most dangerous and risky multiaxial move of the body. This is not in accordance with the experimental observations of Costi et al.44 who investigated the maximum shear strain suggesting that the lateral bending and flexion are the most dangerous movements affecting the disc due to their high physiological values compared to axial torsion for the lumbar spine. These contradictory results reveal the importance of making more complex calculations combining the two studies and measuring the stress levels under the maximum physiological shear strains and taking as well into consideration the local maximum shear stress levels. Indeed, lower maximum shear stress levels could be observed globally in the specimen under a certain mode with high stresses affecting the weak ILM zones that exhibit a lower ultimate stress due to the absence of fibers.
We can conclude that our modeling approach succeeds to predict the multiaxial behavior of the annulus by means of uniaxial experimental data which was supposed to be not possible in the previous literature19,20. The use of a layered model with distinct lamellar and interlamellar layers is mandatory to access the core of the annulus fibrosus and to define their respective role in the disc mechanics. By such a modeling approach, we can identify the critical zones where a likely higher risk of local damage is present under complex external mechanical loadings. All previous layered models considered these zones as common sliding zones separating the lamellae but the role of the ILM zones does not stop trivially there. Their essential role as chemical actuator of the transfer fluid through the annulus tissue and the corresponding unusual transversal behavior was only appreciated through very recent contributions17,18,45. In the present paper, we highlighted for the first time the determining role of the ILM zones on the multiaxial response of the annulus.
As a final point of discussion, let us come back to the mechanics of the whole disc. The compression of the whole disc (due in-vivo to muscular tension and body weight) provokes the uniaxial circumferential stretching of the annulus due to swelling of the nucleus (inner gel-like disc portion), combined to multiaxial mechanical paths during body movements. Although in-vitro experiments allowed to bring insights on the mechanics of the whole disc46,47,48, the annulus/nucleus interaction under complex external mechanical loadings is still an open issue. The construction of a whole disc model including our annulus model (with the regional effects) and the explicit presence of the nucleus would be useful for a thorough understanding of the functionality of the disc and its local behavior. The annulus structure-response relationship varies between individuals, between the different discs of the same spinal column and depends on the degeneration state of the disc. Therefore, it would be useful in the continuity of the model development to generate patient-specific models based on a hybrid methodology combining our modeling approach and direct MRI measurements on functional spine units.
Methods
Computational models
Uniaxial stretching, biaxial stretching and shearing are all considered in this work. The three sets of experiments are replicated in-silico using the finite element method according to the experimental recommendations available in the literature regarding specimen shapes, sizes and mechanical conditions in terms of strain rate and maximum strain. As observed in the works of Gregory and Callaghan49 and Derrouiche et al.45 the strain rate has an effect on the stress–strain and transversal responses of the multilamellar annulus specimen. As a consequence, for all the simulated tests, quasi-static conditions were ensured by using strain rates of 0.002 s−1 and 0.0002 s−1 depending on the strain rate level of the reproduced experimental test. The maximum strain used in all the simulations varies between 5 and 10% which corresponds to the maximum physiological strain level observed experimentally for annulus under compression44,50. The latter values have been often used in many experimental studies16,34. All the geometrical models were meshed using isoparametric and arbitrarily hexahedrics 8-node meshing elements. An adequate element size is chosen to ensure mesh-independency. All the ILM-lamellar interfaces of the stratified soft tissue are considered perfect. The structural features used as model inputs for the different human disc regions are reported in Table 1 and are extracted from well-documented papers of the literature35,51,52,53,54.
Uniaxial stretching conditions and designed material kinetics
A computational model was designed as described by Kandil et al.18 for the uniaxial conditions. Due to the large specimen size and large calculation time, a representative elementary volume (REV) of the specimen was designed in order to reproduce the in-vitro experiments of Ebara et al.34 and Baldit et al.16. A REV of 2 × 2 × 1.6 mm is modeled. The same REV was used to model the experiments of the two papers. Similar boundary conditions were applied but different symmetry conditions were considered in each case. For the Baldit et al.16 specimen, the corresponding modeled REV is one-fourth of the specimen cross-section and one-sixth of the specimen height and for the Ebara et al.34 specimen, it corresponds to one-half of the specimen cross-section and one-sixth of the specimen height.
Experimentally-based kinetics has been designed by Kandil et al.18 using the bovine model. The human disc contains a lower CFs content and a slightly higher water content compared to bovine disc51,55. As illustrated in Fig. 1, a hybrid experimental/modeling strategy for the trans-species transfer from bovine to human intervertebral disc model is adopted via a three-step methodology to reach the final result of model vs. experiments and the related predictions. In the first step, the fluid transfer equations, first developed for bovine annulus by Kandil et al.18, were adapted to the human annulus by adjusting the fluid kinetics on the human (AO and AI) experimental transversal curves of Baldit et al.16 shown in Fig. 1. In the second step, the fiber intrinsic mechanical parameters were identified using the human (AO and AI) experimental stress–strain curves of Ebara et al.34. In the third step, the predictions were made possible in the remaining posterior (PO and PI) regions by applying the related fibers content/orientation and water concentration.
Biaxial stretching conditions
Different biaxial loading cases were simulated with the same specimen dimensions reported for the in-vitro experiments of O’Connell et al.20: 7 × 7 × 1.6 mm. The computational models were subjected to different strain loading ratios (= circumferential strain : axial strain, {1:0, 0:1, 1:2, 2:1 and 1:1}) along with a maximum strain of 5% and a strain rate of 0.0002 s−1. Two sets of tests were established. The first one consisted on circumferential stress calculation while the second one on axial stress calculation, both under the different loading ratios.
Shearing conditions
Three shear modes were simulated following the boundary conditions of Fujita et al.36: 12, 13 and 23 as shown in Fig. 4 using 3.33 mm cubes subjected to a maximum shear strain of 5% and a shear strain rate of 0.0002 s−1. Because the in-vitro experiments of Fujita et al.36 were performed on anterior specimens but without mentioning their exact radial positions, both AO and AI computational models were considered. Due to a negligible fluid transfer upon shearing, the latter was not considered in the computational models.
Microstructure-based chemo-mechanical constitutive model
In what follows, the key points of the chemo-mechanical model are briefly summarized. The model is fully three-dimensional and considers the time-dependency of the annulus fibrosus tissue response in relation to the microstructure, the intrinsic features and the chemical-induced internal fluid variation.
Kinematics
Starting point for the derivation of any finite-strain constitutive model is the kinematics within the framework of nonlinear continuum mechanics. If \({\varvec{x}}\) is the current position of a material point of the continuum body located at \({\varvec{X}}\) in the initial configuration, the deformation gradient tensor is: \({\mathbf{F}} = {{\partial {\varvec{x}}} \mathord{\left/ {\vphantom {{\partial {\varvec{x}}} \partial }} \right. \kern-\nulldelimiterspace} \partial }{\varvec{X}}\). The time derivative is defined as: \({\dot{\mathbf{F}}} = {\mathbf{LF}}\) in which \({\mathbf{L}} = {{\partial {\varvec{v}}} \mathord{\left/ {\vphantom {{\partial {\varvec{v}}} {\partial {\varvec{x}}}}} \right. \kern-\nulldelimiterspace} {\partial {\varvec{x}}}}\) is the spatial velocity gradient tensor with \({\varvec{v}} = {{\partial {\varvec{x}}} \mathord{\left/ {\vphantom {{\partial {\varvec{x}}} {\partial t}}} \right. \kern-\nulldelimiterspace} {\partial t}}\). Let us consider an intermediate virtual configuration for the chemical coupling with the surrounding environment. This concept allows to further multiplicatively split the tensor \({\mathbf{F}}\) into two contributions: \({\mathbf{F}} = {\mathbf{F}}_{mech} {\mathbf{F}}_{chem}\) in which \({\mathbf{F}}_{mech}\) is the mechanical part and \({\mathbf{F}}_{chem}\) is the chemical-induced volumetric part. Using a similar sequence of configurations with an intermediate virtual configuration during a spontaneous elastic unloading, the mechanical deformation gradient tensor \({\mathbf{F}}_{mech}\) is in turn multiplicatively split into an elastic part \({\mathbf{F}}_{e}\) and a viscous part \({\mathbf{F}}_{v}\) such as: \({\mathbf{F}}_{mech} = {\mathbf{F}}_{e} {\mathbf{F}}_{v}\) in the aim representing the intrinsic viscosity of the ECM including all non-fibrillar “solid” components. In view of the mechanical incompressibility of all “solid” components (ECM and CFs), the determinants (Jacobian) of the viscous and elastic deformation gradients are: \(J_{{\text{v}}} = \det \left( {{\mathbf{F}}_{{\text{v}}} } \right) = 1\) and \(J_{{\text{e}}} = \det \left( {{\mathbf{F}}_{{\text{e}}} } \right) = 1\). The chemical-induced volumetric part is: \({\mathbf{F}}_{chem} = {\mathbf{I}}J^{{{1 \mathord{\left/ {\vphantom {1 3}} \right. \kern-\nulldelimiterspace} 3}}}\) in which \({\mathbf{I}}\) is the unit tensor and \(J = \det \left( {\mathbf{F}} \right) > 0\) is the determinant of the deformation gradient tensor, i.e. the tissue volumetric deformation. The spatial velocity gradient tensor \({\mathbf{L}}\) is additively spit into a mechanical part \({\mathbf{L}}_{mech}\) and a chemical part \({\mathbf{L}}_{chem}\) as: \({\mathbf{L}} = {\mathbf{L}}_{mech} + {\mathbf{L}}_{chem}\) with \({\mathbf{L}}_{chem} = {\mathbf{F}}_{mech} {\dot{\mathbf{F}}}_{chem} {\mathbf{F}}_{chem}^{ - 1} {\mathbf{F}}_{mech}^{ - 1} = {\mathbf{I}}{{\dot{J}} \mathord{\left/ {\vphantom {{\dot{J}} {3J}}} \right. \kern-\nulldelimiterspace} {3J}}\) and \({\mathbf{L}}_{mech} = {\dot{\mathbf{F}}}_{mech} {\mathbf{F}}_{mech}^{ - 1} = {\mathbf{L}}_{e} + {\mathbf{L}}_{v}\) in which \({\mathbf{L}}_{e} = {\dot{\mathbf{F}}}_{e} {\mathbf{F}}_{e}^{ - 1}\) is the elastic part and \({\mathbf{L}}_{v} = {\mathbf{F}}_{e} {\dot{\mathbf{F}}}_{v} {\mathbf{F}}_{v}^{ - 1} {\mathbf{F}}_{e}^{ - 1}\) is the viscous part that in turn may be written as: \({\mathbf{L}}_{v} = {\mathbf{D}}_{v} + {\mathbf{W}}_{v}\) in which \({\mathbf{D}}_{v} = {{\left( {{\mathbf{L}}_{v} + {\mathbf{L}}_{v}^{T} } \right)} \mathord{\left/ {\vphantom {{\left( {{\mathbf{L}}_{v} + {\mathbf{L}}_{v}^{T} } \right)} 2}} \right. \kern-\nulldelimiterspace} 2}\) is the (symmetric) viscous stretching rate tensor and \({\mathbf{W}}_{v} = {{\left( {{\mathbf{L}}_{v} - {\mathbf{L}}_{v}^{T} } \right)} \mathord{\left/ {\vphantom {{\left( {{\mathbf{L}}_{v} - {\mathbf{L}}_{v}^{T} } \right)} 2}} \right. \kern-\nulldelimiterspace} 2}\) is the (skew-symmetric) viscous spin rate tensor. The common assumption of viscous irrotationality is applied with no loss in generality56, i.e. \({\mathbf{W}}_{v} = {\mathbf{0}}\) and \({\mathbf{D}}_{v} {\mathbf{ = }}{\mathbf{L}}_{v}\). The different contributions of the right and left Cauchy-Green deformation tensors, \({\mathbf{C}} = {\mathbf{F}}^{{T}} {\mathbf{F}}\) and \({\mathbf{B}} = {\mathbf{FF}}^{{T}}\), are: \({\mathbf{C}}_{mech} = {\mathbf{F}}_{mech}^{T} {\mathbf{F}}_{mech}\), \({\mathbf{B}}_{mech} = {\mathbf{F}}_{mech} {\mathbf{F}}_{mech}^{T}\), \({\mathbf{C}}_{e} = {\mathbf{F}}_{e}^{T} {\mathbf{F}}_{e}\), \({\mathbf{B}}_{e} = {\mathbf{F}}_{e} {\mathbf{F}}_{e}^{T}\), \({\mathbf{C}}_{v} = {\mathbf{F}}_{v}^{T} {\mathbf{F}}_{v}\), \({\mathbf{B}}_{v} = {\mathbf{F}}_{v} {\mathbf{F}}_{v}^{T}\), \({\mathbf{C}}_{chem} = J^{2/3} {\mathbf{I}}\) and \({\mathbf{B}}_{chem} = J^{2/3} {\mathbf{I}}\).
Constitutive equations
In the aim of attributing a constitutive relationship to each main component (ECM, CFs and fluid) of the annulus fibrosus tissue, the free energy function \(\psi\) is additively split via the volume fraction concept:
where \(\phi_{CF}\) is the CFs content, \(\psi_{ECM}\) is the ECM free energy function, \(\psi_{CF}\) is the CFs free energy function and \(\psi_{chem}\) is the chemical-induced volumetric free energy function, respectively, given by:
The free energy function (2) corresponds to a Gent formulation57 in which an additive split into elastic and inelastic contributions is considered. The terms \(I_{1} = {\text{tr}}{\mathbf{B}}_{mech}\) and \(I_{1e} = {\text{tr}}{\mathbf{B}}_{e}\) are the first invariants. The free energy function (3) introduces \(I_{4} = {\varvec{a}}{\mathbf{C}}_{mech} {\varvec{a}}\) as the fourth invariant where \({\varvec{a}} = x{\varvec{e}}_{1} + y{\varvec{e}}_{2} + z{\varvec{e}}_{3}\) is the unit vector in the initial configuration58 (see Fig. 1). The terms \(\lambda_{I} = \sqrt {{\varvec{e}}_{1} {\mathbf{C}}_{mech} {\varvec{e}}_{1} }\), \(\lambda_{II} = \sqrt {{\varvec{e}}_{2} {\mathbf{C}}_{mech} {\varvec{e}}_{2} }\) and \(\lambda_{III} = \sqrt {{\varvec{e}}_{3} {\mathbf{C}}_{mech} {\varvec{e}}_{3} }\) are the stretches along the CFs principal axes. Remind that ILM is a non-fibrillar zone, i.e. \(\phi_{CF}\) = 0 in ILM. The material constants are the ECM tensile modulus \(E\), the ECM limiting extensibility constant \(I_{1}^{\max }\), the ECM viscous constants \(E_{v}\) and \(I_{1v}^{\max }\), the CFs constants \(A_{1}\) and \(A_{2}\), and the bulk modulus \(k\).
The set of free energy functions (2)–(4) forms the basis of a suitable theory to constitutively coordinate the dual stress and strain tensors:
where the mechanical-based Cauchy stresses in the ECM and CFs, \({{\varvec{\upsigma}}}_{ECM}\) and \({{\varvec{\upsigma}}}_{CF}\), are deduced from the differentiation of the free energy functions (2) and (3) with respect to the corresponding deformations:
in which the first term of the left formula corresponds to the elastic Cauchy stress \({{\varvec{\upsigma}}}_{e}\) and the second term corresponds to the viscous Cauchy stress \({{\varvec{\upsigma}}}_{v}\), such that \({{\varvec{\upsigma}}}_{ECM} = {{\varvec{\upsigma}}}_{e} + {{\varvec{\upsigma}}}_{v}\). Note that the mechanical incompressibility of all “solid” components (ECM and CFs) means that the mechanical-based Cauchy stresses in the ECM and CFs are traceless tensors, i.e. \({\text{tr}}\left( {{{\varvec{\upsigma}}}_{e} } \right) = 0\), \({\text{tr}}\left( {{{\varvec{\upsigma}}}_{v} } \right) = 0\) and \({\text{tr}}\left( {{{\varvec{\upsigma}}}_{CF} } \right) = 0\). The chemical-based Cauchy stress \({{\varvec{\upsigma}}}_{chem} = p{\mathbf{I}}\) (\(p = {{{\text{tr}}\left( {{\varvec{\upsigma}}} \right)} \mathord{\left/ {\vphantom {{{\text{tr}}\left( {{\varvec{\upsigma}}} \right)} 3}} \right. \kern-\nulldelimiterspace} 3}\) being the hydrostatic pressure) is deduced from the differentiation of the free energy function (4) with respect to the tissue volumetric deformation:
The driving force for the viscous Cauchy stress \({{\varvec{\upsigma}}}_{v}\) is the elastic deformation gradient tensor \({\mathbf{F}}_{e} = {\mathbf{F}}_{mech} {\mathbf{F}}_{v}^{ - 1}\), the viscous deformation gradient tensor \({\mathbf{F}}_{v}\) being computed via \({\dot{\mathbf{F}}}_{v} {\mathbf{ = F}}_{e}^{ - 1} {\mathbf{D}}_{v} {\mathbf{F}}_{mech}\). The viscous stretching rate tensor \({\mathbf{D}}_{v}\) is described by the following flow rule: \({\mathbf{D}}_{v} = \dot{\gamma }_{v} {{{\varvec \sigma^{\prime}}_{v} } \mathord{\left/ {\vphantom {{{\sigma^{\prime}}_{v} } {\sqrt 2 \left\| {{{\varvec{\upsigma}}}_{v} } \right\|}}} \right. \kern-\nulldelimiterspace} {\sqrt 2 \left\| {{{\varvec{\upsigma}}}_{v} } \right\|}}\) where \(\left\| {{{\varvec{\upsigma}}}_{v} } \right\| = \sqrt {{{{\text{tr}}\left( {{\varvec \sigma^{\prime}}_{v} {\varvec \sigma^{\prime}}_{v} } \right)} \mathord{\left/ {\vphantom {{{\text{tr}}\left( {{\mathbf{\sigma^{\prime}}}_{v} {\mathbf{\sigma^{\prime}}}_{v} } \right)} 2}} \right. \kern-\nulldelimiterspace} 2}}\) is the effective value of the viscous Cauchy stress \({{\varvec{\upsigma}}}_{v}\), \({\varvec \sigma^{\prime}}_{v}\) is the deviatoric part of \({{\varvec{\upsigma}}}_{v}\) and \(\dot{\gamma }_{v}\) is the accumulated viscous strain rate. Invoking a viscoplasticity with no threshold59, the following expression is retained60:
where \(d\) is the ECM viscous multiplier constant and \(m\) is the ECM viscous stretch-dependency constant. The term \(I_{1v} = {\text{tr}}{\mathbf{B}}_{v}\) is the first invariant of the left Cauchy-Green strain tensor \({\mathbf{B}}_{v} = {\mathbf{F}}_{v} {\mathbf{F}}_{v}^{T}\).
The fluid flow governs the transversal strains (radially and axially) and is responsible of the unusual Poisson's ratios of the tissue. For this reason accurate experimentally-based fluid kinetics is required, which is the missing point of all available papers in the literature. The adopted fluid flow kinetics is defined by the Jacobian \(J\) as follows:
in which \(\Delta J\) represents the tissue swelling function controling the fluid movement inside the disc under mechanical loading, \(n_{{f_{m} }}\) is the internal fluid content, \(\xi\) is a dimensionless transportation coefficient, \(\eta\) is a dimensionless free swelling coefficient (equal to 0.5 in the case of physiological salt condition) and \(n_{{f_{m} }}\) is the internal fluid content. The latter is controlled by:
where \(\beta_{m}\) is the fluid flow constant and \(n_{{f_{lim} }}\) is the maximum fluid content that could be reached inside the disc.
The constitutive model has been implemented into the finite element code MSC.Marc by means of a set of subroutines. The main calculation steps of the model implementation are provided elsewhere18. The reader is also referred to complementary references61,62 for the general implementation procedure of coupled models.
Parameters identification
The model parameters and the material kinetics have been determined using experimental data in order to represent the human disc annulus response in connection to microstructure differences in the different disc regions (Table 1). The experimentally-based fluid flow kinetics is guided by the applied mechanical loading and the osmotic effect. Also, due to the fibers presence retarding the fluid movement in lamellae and the difference of the fixed charges density in the two zones, ILM and lamellae behave differently. The values of \(\beta_{m}\) are, respectively, for the lamellae and ILM zones:
The transportation coefficient \(\xi\) is a function of the strain rate \(\dot{\varepsilon }\) and is described by the following equations for the lamellae and ILM zones:
The difference in the inner and outer disc volumetric responses is translated by different bulk moduli:
Note that the fluid kinetics of Kandil et al.18 is found able to reproduce the typical transversal strain history reported by Baldit et al.16. Similar trends are obtained with the newly identified human parameters due to the close water content between human and bovine. Although the ECM stiffness could vary from a disc region to another, it was chosen to be the same throughout the disc due to its small contribution to the complete disc stiffness compared to the fibers and its value was taken from the literature63,64. The intrinsic viscoelasticity of the ECM was also considered regional independent. The set of ECM material constants is:
The effect of CFs is considered to be mainly governed by their content and orientation. The CFs intrinsic mechanical parameters would not change for the different disc regions:
References
Vos, T. et al. Global, regional, and national incidence, prevalence, and years lived with disability for 310 diseases and injuries, 1990–2015: A systematic analysis for the Global Burden of Disease Study 2015. Lancet 388, 1545–1602 (2016).
Shirazi-Adl, S. A., Shrivastava, S. C. & Ahmed, A. M. Stress analysis of the lumbar disc-body unit in compression. A three dimensional nonlinear finite element study. Spine 9, 120–134 (1984).
Klisch, S. M. & Lotz, J. C. Application of a fiber-reinforced continuum theory to multiple deformations of the annulus fibrosus. J. Biomech. 32, 1027–1036 (1999).
Wagner, D. R. & Lotz, J. C. Theoretical model and experimental results for the nonlinear elastic behavior of human annulus fibrosus. J. Orth. Res. 22, 901–909 (2004).
Guo, Z. Y., Peng, X. Q. & Moran, B. A composites-based hyperelastic constitutive model for soft tissue with application to the human annulus fibrosus. J. Mech. Phys. Solids 54, 1952–1971 (2006).
Guerin, H. A. L. & Elliott, D. M. Quantifying the contributions of structure to annulus fibrosus mechanical function using a nonlinear, anisotropic, hyperelastic model. J. Orth. Res. 25, 508–516 (2007).
Argoubi, M. & Shirazi-Adl, A. Poroelastic creep response analysis of a lumbar motion segment in compression. J. Biomech. 29, 1331–1339 (1996).
Ayotte, D. C., Ito, K., Perren, S. M. & Tepic, S. Direction-dependent constriction flow in a poroelastic solid: The intervertebral disc valve. J. Biomech. Eng. 122, 587–593 (2000).
Klisch, S. M. & Lotz, J. C. A special theory of biphasic mixtures and experimental results for human annulus fibrosus tested in confined compression. J. Biomech. Eng. 122, 180–188 (2000).
Riches, P. E., Dhillon, N., Lotz, J., Woods, A. W. & McNally, D. S. The internal mechanics of the intervertebral disc under cyclic loading. J. Biomech. 35, 1263–1271 (2002).
Huyghe, J. M. & Janssen, J. D. Quadriphasic mechanics of swelling incompressible porous media. Inter. J. Eng. Sci. 35, 793–802 (1997).
Schroeder, Y., Wilson, W., Huyghe, J. M. & Baaijens, F. P. T. Osmoviscoelastic finite element model of the intervertebral disc. Eur. Spine J. 15, 361–371 (2006).
Ehlers, W., Karajan, N. & Markert, B. An extended biphasic model for charged hydrated tissues with application to the intervertebral disc. Biomech. Model. Mech. 8, 233–251 (2009).
Zhou, M., Bezci, S. E. & O’Connell, G. D. Multiscale composite model of fiber-reinforced tissues with direct representation of sub-tissue properties. Biomech. Model. Mech. 19, 745–759 (2020).
Wilson, W., van Donkelaar, C. C., van Rietbergen, C., Ito, K. & Huiskes, R. Stresses in the local collagen network of articular cartilage: A poroviscoelastic fibril-reinforced finite element study. J. Biomech. 37, 357–366 (2004).
Baldit, A., Ambard, D., Cherblanc, F. & Royer, P. Experimental analysis of the transverse mechanical behaviour of annulus fibrosus tissue. Biomech. Model. Mech. 13, 643–652 (2014).
Derrouiche, A., Zaïri, F. & Zaïri, F. A chemo-mechanical model for osmo-inelastic effects in the annulus fibrosus. Biomech. Model. Mech. 18, 1773–1790 (2019).
Kandil, K., Zaïri, F., Derrouiche, A., Messager, T. & Zaïri, F. Interlamellar-induced time-dependent response of intervertebral disc annulus: A microstructure-based chemo-viscoelastic model. Acta Biomater. 200, 75–91 (2019).
Bass, E. C., Ashford, F. A., Segal, M. R. & Lotz, J. C. Biaxial testing of human annulus fibrosus and its implications for a constitutive formulation. Ann. Biomed. Eng. 32, 1231–1242 (2004).
O’Connell, G. D., Sen, S. & Elliott, D. M. Human annulus fibrosus material properties from biaxial testing and constitutive modeling are altered with degeneration. Biomech. Model. Mech. 11, 493–503 (2012).
Peng, X. Q., Guo, Z. Y. & Moran, B. An anisotropic hyperelastic constitutive model with fiber-matrix shear interaction for the human annulus fibrosus. J. Appl. Mech. 73, 815–824 (2005).
Del Palomar, A. P., Calvo, B. & Doblare, M. An accurate finite element model of the cervical spine under quasi-static loading. J. Biomech. 41, 523–531 (2008).
Wagner, D. R., Reiser, K. M. & Lotz, J. C. Glycation increases human annulus fibrosus stiffness in both experimental measurements and theoretical predictions. J. Biomech. 39, 1021–1029 (2006).
Hollingsworth, N. T. & Wagner, D. R. Modeling shear behavior of the annulus fibrosus. J. Mech. Behav. Biomed. Mater. 4, 1103–1114 (2011).
Pezowicz, C. A., Robertson, P. A. & Broom, N. D. Intralamellar relationships within the collagenous architecture of the annulus fibrosus imaged in its fully hydrated state. J. Anat. 207, 299–312 (2005).
Pezowicz, C. A., Robertson, P. A. & Broom, N. D. The structural basis of interlamellar cohesion in the intervertebral disc wall. J. Anat. 208, 317–330 (2006).
Gregory, D. E., Bae, W. C., Sah, R. L. & Masuda, K. Anular delamination strength of human lumbar intervertebral disc. Eur. Spine J. 21, 1716–1723 (2012).
Labus, K. M., Han, S. K., Hsieh, A. H. & Puttlitz, C. M. A computational model to describe the regional interlamellar shear of the annulus fibrosus. J. Biomech. Eng. 136, 051009 (2014).
Adam, C., Rouch, P. & Skalli, W. Inter-lamellar shear resistance confers compressive stiffness in the intervertebral disc: an image-based modelling study on the bovine caudal disc. J. Biomech. 48, 4303–4308 (2015).
Mengoni, M. et al. Derivation of inter-lamellar behaviour of the intervertebral disc annulus. J. Mech. Behav. Biomed. Mater. 48, 164–172 (2015).
Tavakoli, J., Elliott, D. M. & Costi, J. J. The ultra-structural organization of the elastic network in the intra- and inter-lamellar matrix of the intervertebral disc. Acta Biomater. 58, 269–277 (2017).
Tavakoli, J. & Costi, J. J. New findings confirm the viscoelastic behaviour of the inter-lamellar matrix of the disc annulus fibrosus in radial and circumferential directions of loading. Acta Biomater. 71, 411–419 (2018).
Skaggs, D. L., Weidenbaum, M., Iatridis, J. C., Ratcliffe, A. & Mow, V. C. Regional variation in tensile properties and biochemical composition of the human lumbar anulus fibrosus. Spine 19, 1310–1319 (1994).
Ebara, S. et al. Tensile properties of nondegenerate human lumbar anulus fibrosus. Spine 21, 452–461 (1996).
Holzapfel, G. A., Schulze-Bauer, C. A. J., Feigl, G. & Regitnig, P. Single lamellar mechanics of the human lumbar anulus fibrosus. Biomech. Model. Mech. 3, 125–140 (2005).
Fujita, Y., Wagner, D. R., Biviji, A. A., Duncan, N. A. & Lotz, J. C. Anisotropic shear behavior of the annulus fibrosus: Effect of harvest site and tissue prestrain. Med. Eng. Phys. 22, 349–357 (2000).
Tsuji, H. et al. Structural variation of the anterior and posterior annulus fibrosus in the development of human lumbar intervertebral disc: A risk factor for intervertebral disc rupture. Spine 18, 204–210 (1993).
Smith, L. J. & Fazzalari, N. L. Regional variations in the density and arrangement of elastic fibres in the anulus fibrosus of the human lumbar disc. J. Anat. 209, 359–367 (2006).
Iatridis, J. C., Kumar, S., Foster, R. J., Weidenbaum, M. & Mow, V. C. Shear mechanical properties of human lumbar annulus fibrosus. J. Orth. Res. 17, 732–737 (1999).
Gregory, D. E. & Callaghan, J. P. A comparison of uniaxial and biaxial mechanical properties of the annulus fibrosus: A porcine model. J. Biomech. Eng. 133, 024503 (2011).
Goel, V. K., Monroe, B. T., Gilbertson, L. G. & Brinckmann, P. Interlaminar shear stresses and laminae separation in a disc: Finite element analysis of the L3–L4 motion segment subjected to axial compressive loads. Spine 20, 689–698 (1995).
Michalek, A. J., Buckley, M. R., Bonassar, L. J., Cohen, I. & Iatridis, J. C. Measurement of local strains in intervertebral disc anulus fibrosus tissue under dynamic shear: Contributions of matrix fiber orientation and elastin content. J. Biomech. 42, 2279–2285 (2009).
Jacobs, N. T. et al. Effect of orientation and targeted extracellular matrix degradation on the shear mechanical properties of the annulus fibrosus. J. Mech. Behav. Biomed. Mater. 4, 1611–1619 (2011).
Costi, J. J. et al. Direct measurement of intervertebral disc maximum shear strain in six degrees of freedom: Motions that place disc tissue at risk injury. J. Biomech. 40, 2457–2466 (2007).
Derrouiche, A. et al. The two Poisson’s ratios in annulus fibrosus: Relation with the osmo-inelastic features. Mech. Soft Mater. 2, 1 (2020).
Derrouiche, A. et al. Osmo-inelastic response of the intervertebral disc. Proc. Inst. Mech. Eng. H J. Eng. Med. 233, 332–341 (2019).
Derrouiche, A. et al. How pre-strain affects the chemo-torsional response of the intervertebral disc. Clin. Biomech. 76, 105020 (2020).
Feki, F. et al. How osmoviscoelastic coupling affects recovery of cyclically compressed intervertebral disc. Spine 45, 1376–1385 (2020).
Gregory, D. E. & Callaghan, J. P. An examination of the influence of strain rate on subfailure mechanical properties of the annulus fibrosus. J. Biomech. Eng. 132, 091010 (2010).
Shirazi-Adl, A. Strain in fibers of a lumbar disc: Analysis of the role of lifting in producing disc prolapsed. Spine 14, 96–103 (1989).
Showalter, B. L. et al. Comparison of animal discs used in disc research to human lumbar disc: Torsion mechanics and collagen content. Spine 37, 900–907 (2012).
Eyre, D. R. & Muir, H. Types I and II collagens in intervertebral disc. Interchanging radial distributions in annulus fibrosus. Biochem. J. 157, 267–270 (1976).
Eyre, D. R. & Muir, H. Quantitative analysis of types I and II collagens in the human intervertebral discs at various ages. Biochim. Biophys. Acta 492, 29–42 (1977).
Iatridis, J. C., MacLean, J. J., O’Brien, M. & Stokes, I. A. Measurements of proteoglycan and water content distribution in human lumbar intervertebral discs. Spine 32, 1493–1497 (2007).
Beckstein, J. C., Sen, S., Schaer, T. P., Vresilovic, E. J. & Elliott, D. M. Comparison of animal discs used in disc research to human lumbar disc: Axial compression mechanics and glycosaminoglycan content. Spine 33, 166–173 (2008).
Gurtin, M. E. & Anand, L. The decomposition F=FeFp, material symmetry, and plastic irrotationality for solids that are isotropic-viscoplastic or amorphous. Int. J. Plast. 21, 1686–1719 (2005).
Gent, A. N. A new constitutive relation for rubber. Rubber Chem. Technol. 69, 59–61 (1996).
Cantournet, S., Boyce, M. C. & Tsou, A. H. Micromechanics and macromechanics of carbon nanotube-enhanced elastomers. J. Mech. Phys. Solids 55, 1321–1339 (2007).
Pyrz, M. & Zaïri, F. Identification of viscoplastic parameters of phenomenological constitutive equations for polymers by deterministic and evolutionary approach. Model. Simul. Mater. Sci. Eng. 15, 85–103 (2007).
Bergstrom, J. S. & Boyce, M. C. Constitutive modeling of the large strain time-dependent behavior of elastomers. J. Mech. Phys. Solids 46, 931–954 (1998).
Ovalle-Rodas, C., Zaïri, F., Naït-Abdelaziz, M. & Charrier, P. A thermo-visco-hyperelastic model for the heat build-up during low-cycle fatigue of filled rubbers: Formulation, implementation and experimental verification. Int. J. Plast. 79, 217–236 (2016).
Guo, Q., Zaïri, F. & Guo, X. A thermo-viscoelastic-damage constitutive model for cyclically loaded rubbers. Part I: model formulation and numerical examples. Int. J. Plast. 101, 106–124 (2018).
Yao, J., Turteltaub, S. R. & Ducheyne, P. A three-dimensional nonlinear finite element analysis of the mechanical behavior of tissue engineered intervertebral discs under complex loads. Biomaterials 27, 377–387 (2006).
Tang, S. & Rebholz, B. J. Does anterior lumbar interbody fusion promote adjacent degeneration in degenerative disc disease? A finite element study. J. Orthop. Sci. 16, 221–228 (2011).
Acknowledgements
The authors gratefully acknowledge the French ministry of higher education and research for its financial support.
Author information
Authors and Affiliations
Contributions
K. K. designed the present study under the supervision of F. Z., and T. M.; F. Z. supervised the medical and biological aspects of the study; K. K. performed the calculations, the formal analysis, the visualization and the data curation; F. Z. designed the conceptualization and the methodology of the present study and performed the project management; K. K. and F. Z. wrote, reviewed and edited the manuscript. All the authors contributed to the discussion during the whole project.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kandil, K., Zaïri, F., Messager, T. et al. Interlamellar matrix governs human annulus fibrosus multiaxial behavior. Sci Rep 10, 19292 (2020). https://doi.org/10.1038/s41598-020-74107-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-74107-8
- Springer Nature Limited
This article is cited by
-
Understanding the Recovery of the Intervertebral Disc: A Comprehensive Review of In Vivo and In Vitro Studies
Journal of Bionic Engineering (2024)
-
A Microstructure-Based Mechanistic Approach to Detect Degeneration Effects on Potential Damage Zones and Morphology of Young and Old Human Intervertebral Discs
Annals of Biomedical Engineering (2023)
-
A microstructure-based model for time-dependent mechanics of multi-layered soft tissues and its application to intervertebral disc annulus
Meccanica (2021)